User contributions
Jump to navigation
Jump to search
- 11:47, 14 February 2022 diff hist 0 File:ASML Reticle Programming Params - MASKJAN2020 v1.xlsx John d uploaded a new version of File:ASML Reticle Programming Params - MyReticleBarCode v1.xlsx
- 13:49, 11 February 2022 diff hist +53 m ICP Etch 2 (Panasonic E626I) →Recipes Tag: Visual edit
- 13:48, 11 February 2022 diff hist +97 ICP Etch 1 (Panasonic E646V) separate process control section/link Tag: Visual edit
- 13:47, 11 February 2022 diff hist +59 ICP Etch 2 (Panasonic E626I) →Recipes: separate Process Control section/link Tag: Visual edit
- 13:24, 11 February 2022 diff hist +31 Test Data of etching SiO2 with CHF3/CF4 minor update to diamond experiemnt comment. Tag: Visual edit
- 13:23, 11 February 2022 diff hist -36 ICP Etching Recipes →ICP Etch 2 (Panasonic E640): updated ICP1 and ICP2 with Process Control sections for SiO2 etch tests. Tag: Visual edit
- 13:22, 11 February 2022 diff hist +252 N MediaWiki:Deletereason-dropdown added common NanoFab reasons for deletion current
- 13:19, 11 February 2022 diff hist +504 Test Data of etching SiO2 with CHF3/CF4-ICP1 new section :pasted data from CHF3/CF4/O2 etch data
- 13:13, 11 February 2022 diff hist +22 ICP Etching Recipes →SiO2 Etch Historical Data: reanmed to include tool name Tag: Visual edit
- 13:12, 11 February 2022 diff hist -37 ICP Etching Recipes →SiO2 Etching (Fluorine ICP Etcher): consolidated FL-ICP Prcoess Control data Tag: Visual edit
- 13:11, 11 February 2022 diff hist +493 Test Data of Etching SiO2 with CHF3/CF4-Fluorine ICP Etcher pasted Ning's 2nd data table, hilighted recipe changes and comment about data being "in progress"
- 12:28, 11 February 2022 diff hist +1 ICP Etching Recipes →PlasmaTherm/SLR Fluorine Etcher: moved historical data to top Tag: Visual edit
- 12:46, 4 February 2022 diff hist +260 Template:Announcements ASML maintenance
- 15:24, 1 February 2022 diff hist +3 m Autostep 200 Mask Making Guidance →Mask Layout Tag: Visual edit
- 15:23, 1 February 2022 diff hist +119 m Autostep 200 Mask Making Guidance →Photomask Ordering Info Tag: Visual edit
- 10:00, 1 February 2022 diff hist +327 Autostep 200 Mask Making Guidance →Photomask Ordering Info: added info Tag: Visual edit
- 09:39, 1 February 2022 diff hist +428 Autostep 200 Mask Making Guidance →Alignment Marks: adde Vernier CAD file Tag: Visual edit
- 09:37, 1 February 2022 diff hist +110 N File:Vernier Template.gds Vernier Registration/Alignment Test structure for lithography. Designed by Demis D. John, 2008.
- 09:03, 1 February 2022 diff hist -14 m Stepper 2 (AutoStep 200) →Process Information Tag: Visual edit
- 17:30, 31 January 2022 diff hist +185 Autostep 200 Mask Making Guidance →Mask Layout: 2nd attempt to describe Shutter positioning Tag: Visual edit
- 17:19, 31 January 2022 diff hist +352 Autostep 200 Mask Making Guidance →Mask Layout: 1st attempt at describing shutter blades Tag: Visual edit
- 17:00, 31 January 2022 diff hist +172 Autostep 200 Mask Making Guidance →Mask Layout / Alignment Marks: split into Mask layout separate section Tag: Visual edit
- 16:55, 31 January 2022 diff hist +30 Autostep 200 Troubleshooting and Recovery →What to do if you cannot undo the problem or need some help: link to each contact, update to use "Report tool issue' button on SUM current Tag: Visual edit
- 17:09, 28 January 2022 diff hist +358 m Oxford ICP Etcher - Process Control Data →Data - InP Ridge Etch (Oxford ICP Etcher) Tag: Visual edit
- 17:06, 28 January 2022 diff hist +805 Oxford ICP Etcher - Process Control Data updated tables, split into "sample size dpeendence" table Tag: Visual edit
- 21:43, 27 January 2022 diff hist +356 MLA150 - Troubleshooting →Solutions for small substrates: added THomas Messner's solution: disable Overview Camera before starting exposure Tag: Visual edit
- 11:42, 24 January 2022 diff hist -26 Packaging Recipes →Blade Exposure Calculation: image size increase Tag: Visual edit: Switched
- 11:13, 24 January 2022 diff hist +40 m Packaging Recipes →Anatomy of a Blade Tag: Visual edit
- 10:55, 21 January 2022 diff hist +346 Atomic Layer Deposition Recipes →Temperature: mentioned "thermal" and slower rate. Tag: Visual edit
- 10:53, 21 January 2022 diff hist +661 Atomic Layer Deposition Recipes →Al2O3 deposition (ALD CHAMBER 3): added terms "Plasma/Thermal/Ozone". Also added Chamber 1 Al2O3 Tag: Visual edit
- 23:12, 13 January 2022 diff hist +133 ICP Etching Recipes →Oxford ICP Etcher (PlasmaPro 100 Cobra): GaN ALE section started Tag: Visual edit
- 23:11, 13 January 2022 diff hist +238 ICP Etching Recipes →Oxford ICP Etcher (PlasmaPro 100 Cobra): NOTE: Rates in these 2021-09 characterizations are lower than current due to a software timing bug, fixed in 2022-01 Tag: Visual edit
- 23:09, 13 January 2022 diff hist +174 Oxford ICP Etcher - Process Control Data described basic 'fab process Tag: Visual edit
- 23:07, 13 January 2022 diff hist +55 ICP Etching Recipes →Process Control Data (Oxford ICP Etcher) Tag: Visual edit
- 23:05, 13 January 2022 diff hist -17 m Oxford ICP Etcher - Process Control Data removed WIP Tag: Visual edit
- 23:03, 13 January 2022 diff hist +56 Oxford ICP Etcher - Process Control Data added SEM images for Jan 11th-12th cals Tag: Visual edit
- 23:03, 13 January 2022 diff hist +36 N File:2022-01-12 Oxford InP Ridge Wiki Post - Cal03.pdf Oxford ICP Etch Cals03 current
- 22:55, 13 January 2022 diff hist +33 N File:2022-01-12 Oxford InP Ridge Wiki Post - Cal02.pdf Oxford ICP Cal SEMs current
- 22:51, 13 January 2022 diff hist +161 Oxford ICP Etcher - Process Control Data →Data - InP Ridge Etch (Oxford ICP Etcher): updated SEM 1 Tag: Visual edit
- 22:51, 13 January 2022 diff hist +38 N File:2022-01-11 Oxford InP Ridge Wiki Post - Cal01.pdf Oxford ICP Etch Cal SEMs current
- 21:43, 13 January 2022 diff hist +84 m MLA150 - Troubleshooting →Unexpected Behavior Tag: Visual edit
- 21:41, 13 January 2022 diff hist +271 MLA150 - Troubleshooting →Out Of Focus Exposures: Boris’ solutionnadded Tag: Visual edit
- 14:24, 13 January 2022 diff hist -1,009 Oxford ICP Etcher - Process Control Data in progress InP Ridge Etch Tag: Visual edit
- 14:21, 13 January 2022 diff hist +1,617 N Oxford ICP Etcher - Process Control Data pasted ICP2 data table Tag: Visual edit: Switched
- 14:21, 13 January 2022 diff hist +156 Oxford ICP Etcher (PlasmaPro 100 Cobra) →Recipes: link to Process Control Data Tag: Visual edit
- 14:20, 13 January 2022 diff hist +3 ICP Etching Recipes →Historical Data (Oxford ICP Etcher): changed to "process control data" Tag: Visual edit
- 14:18, 13 January 2022 diff hist +208 ICP Etching Recipes →Oxford ICP Etcher (PlasmaPro 100 Cobra): link to Historical Data Tag: Visual edit
- 15:14, 12 January 2022 diff hist +136 Frequently Asked Questions →Cell Phone Calls: mention eduroam network Tag: Visual edit
- 15:11, 12 January 2022 diff hist +189 m Frequently Asked Questions →Forcing Calls to use Wifi (not Cellular) Tag: Visual edit
- 15:08, 12 January 2022 diff hist +441 Frequently Asked Questions →Forcing Calls to use Wifi (not Cellular): additional troubleshooting Tag: Visual edit
- 15:22, 11 January 2022 diff hist -42 Stepper 3 (ASML DUV) →Operating Procedures: merged Troubleshooting into Operating Procedures Tag: Visual edit
- 10:43, 11 January 2022 diff hist +675 ASML Stepper 3 Error Recovery, Troubleshooting and Calibration →IQC (Image Quality Control) Calibration Check: method for adding focus correction to exposure Tag: Visual edit: Switched
- 08:48, 7 January 2022 diff hist +113 Video Training: Uploading to GauchoCast/Panopto (Internal) →Uploading to the Web current Tag: Visual edit: Switched
- 08:45, 7 January 2022 diff hist +13 Nanofab Staff Internal Pages →Video Training procedures Tag: Visual edit
- 08:43, 7 January 2022 diff hist +2,328 N Video Training - Introduction (Internal) general methods - Demis current Tag: Visual edit
- 08:24, 7 January 2022 diff hist +89 Nanofab Staff Internal Pages →NanoFab IT: mentoined where to find instrucitons on Google Drive Tag: Visual edit
- 22:33, 6 January 2022 diff hist +91 Nanofab Staff Internal Pages moved olf pages to bottom Tag: Visual edit
- 22:32, 6 January 2022 diff hist +183 Nanofab Staff Internal Pages added NanoFab IT, and linked to NanoFab-it OnDema filter/page Tag: Visual edit
- 23:08, 4 January 2022 diff hist +6 m Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): credit Demis for the data Tag: Visual edit
- 14:58, 4 January 2022 diff hist +159 UCSB NanoFab Microscope Training →Depth Measurements using focus: added meas. error Tag: Visual edit
- 12:54, 4 January 2022 diff hist +100 m Packaging Recipes →Blade Exposure Calculation Tag: Visual edit
- 12:52, 4 January 2022 diff hist -30 m Packaging Recipes →Blade Exposure Calculation: enlarge img Tag: Visual edit
- 12:51, 4 January 2022 diff hist +191 Packaging Recipes →Calculated Blade Exposures: added blade exposure calc Tag: Visual edit
- 12:50, 4 January 2022 diff hist +37 N File:ADT Dicing - Blade Exposure diagram.png current
- 12:41, 4 January 2022 diff hist +1,753 Packaging Recipes →Dicing Saw Recipes (ADT 7100): added Dicing Tips Tag: Visual edit
- 11:29, 4 January 2022 diff hist +35 Tool List →Inspection, Test and Characterization: rearranged, moved "other properties" to end, renamed "Surfscan" to "particle counts" Tag: Visual edit
- 11:13, 4 January 2022 diff hist +79 Test Data of etching SiO2 with CHF3/CF4 →Alternate Data (not updated since 2019) Tag: Visual edit
- 11:12, 4 January 2022 diff hist +209 Test Data of etching SiO2 with CHF3/CF4 pasted link to alternate etch data Tag: Visual edit
- 11:11, 4 January 2022 diff hist -158 ICP Etching Recipes →Historical Data (SiO2 Etch, Panasonic 2): removed 2nd data table Tag: Visual edit
- 13:36, 3 January 2022 diff hist -693 Template:Announcements Deleted Flu vacc. mandate
- 13:34, 3 January 2022 diff hist +4 Template:Announcements →Jan 2022 UCSB COVID Protocols
- 13:33, 3 January 2022 diff hist +1,993 Template:Announcements pasted useful UCSB Jan COVID policiues
- 16:10, 21 December 2021 diff hist 0 File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png John d uploaded a new version of File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png current
- 16:09, 21 December 2021 diff hist +36 MLA150 - Troubleshooting →Out Of Focus Exposures: "features less than 100µm" Tag: Visual edit
- 11:52, 21 December 2021 diff hist -5 m MLA150 - Troubleshooting →Out Of Focus Exposures Tag: Visual edit
- 11:52, 21 December 2021 diff hist +285 MLA150 - Troubleshooting →Out Of Focus Exposures: inserted image of out-of-focus exposure Tag: Visual edit
- 11:50, 21 December 2021 diff hist +87 N File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png
- 11:39, 21 December 2021 diff hist -3 m MLA150 - Troubleshooting fix bullets
- 11:38, 21 December 2021 diff hist -2 m MLA150 - Troubleshooting →Unexpected Behavior Tag: Visual edit
- 11:34, 21 December 2021 diff hist -38 MLA150 - Troubleshooting rearranged sections, increased heading level to 1 & 2 Tag: Visual edit
- 11:07, 21 December 2021 diff hist +62 MLA150 - Troubleshooting Tag: Visual edit
- 00:26, 16 December 2021 diff hist +182 Nanofab Staff Internal Pages →Old / Defunct Tag: Visual edit
- 00:21, 16 December 2021 diff hist +94 m Ion Beam Deposition (Veeco NEXUS) →Recipes Tag: Visual edit
- 00:19, 16 December 2021 diff hist -424 Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): deleted IBD Cals spreadsheet Tag: Visual edit
- 00:18, 16 December 2021 diff hist +426 Old Deposition Data - 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): added IBD Cals spreadsheet current Tag: Visual edit
- 00:15, 16 December 2021 diff hist -2 Old Deposition Data - 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): promoted to Page Title
- 00:15, 16 December 2021 diff hist +359 Old Deposition Data - 2021-12-15 →SiO2 deposition (IBD): added old IBD data Tag: Visual edit
- 00:12, 16 December 2021 diff hist +6,481 Old Deposition Data - 2021-12-15 pasted Old (2021-12-15) IBD recipe data
- 00:11, 16 December 2021 diff hist -613 Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): pasted Nastazia M's new data
- 00:09, 16 December 2021 diff hist -12,460 PECVD Recipes pasted NastaziaM's new data links
- 00:07, 16 December 2021 diff hist +167 Deposition Data - temporary 2021-12-15 →Standard Cleaning Procedure (IBD): cleaning current Tag: Visual edit
- 00:05, 16 December 2021 diff hist +575 Deposition Data - temporary 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): pasted SiOxNy data
- 00:03, 16 December 2021 diff hist +2,234 Deposition Data - temporary 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): updated IBD Tag: Visual edit
- 23:49, 15 December 2021 diff hist +1,751 Deposition Data - temporary 2021-12-15 New data links Tag: Visual edit
- 07:35, 15 December 2021 diff hist +24,157 N Old Deposition Data - 2021-12-15 Created page with "OLD Data: Copied on 2021-12-14 {{recipes|Vacuum Deposition}} =PECVD 1 (PlasmaTherm 790)= ====Historical Particulate Data==== *[https://docs.google.com/spreadsheets/d..." Tag: Visual edit: Switched
- 07:35, 15 December 2021 diff hist +107 Nanofab Staff Internal Pages →Old / Defunct Tag: Visual edit
- 07:32, 15 December 2021 diff hist -11,328 Deposition Data - temporary 2021-12-15
- 07:31, 15 December 2021 diff hist +26 Deposition Data - temporary 2021-12-15 Tag: Visual edit
- 07:31, 15 December 2021 diff hist +24,158 N Deposition Data - temporary 2021-12-15 pasted old data
- 07:30, 15 December 2021 diff hist +83 Nanofab Staff Internal Pages →Old / Defunct: temp. link to dep data Tag: Visual edit
- 06:10, 15 December 2021 diff hist +1,908 MLA150 - Troubleshooting →Out Of Focus Exposures: Debugging section Tag: Visual edit
- 09:31, 14 December 2021 diff hist +598 Old Deposition Data - NastaziaM 2021-11-22 modified PECVD1 and PECVD 1 for same titles as old data current Tag: Visual edit
- 09:20, 14 December 2021 diff hist +24,230 Old Deposition Data - NastaziaM 2021-11-22 pasted all old data from https://wiki.nanotech.ucsb.edu/wiki/PECVD_Recipes Tag: Visual edit
- 09:02, 14 December 2021 diff hist +10 m Nanofab Staff Internal Pages Tag: Visual edit
- 09:21, 11 December 2021 diff hist +115 m ICP Etching Recipes →Si Deep RIE (PlasmaTherm/Bosch Etch): linnks to new DSE & FL_ICP recipes Tag: Visual edit
- 09:20, 11 December 2021 diff hist +331 ICP Etching Recipes →Oxford ICP Etcher (PlasmaPro 100 Cobra): links for GaAs, GaSb Tag: Visual edit
- 12:16, 8 December 2021 diff hist +504 N MA6 Backside Alignment - Allowed Mark Locations 100-mm BSA chuck with cutouts measurements current Tag: Visual edit
- 12:15, 8 December 2021 diff hist +67 N File:MA-6 4-inch BSA chuck - 2631 - measurements.jpg current
- 12:12, 8 December 2021 diff hist +53 Contact Aligner (SUSS MA-6) →Documentation: link to "backside alignment - allowed mark locations" Tag: Visual edit
- 12:10, 8 December 2021 diff hist +2 m Contact Aligner (SUSS MA-6) minor wording Tag: Visual edit
- 12:11, 7 December 2021 diff hist 0 m Template:Announcements →New COVID Protocols: minor formatting
- 12:10, 7 December 2021 diff hist -1,191 Template:Announcements delete old Weekly-Testing & COVID-Protocols & OxfordICP messages
- 11:01, 1 December 2021 diff hist +439 DSEIII (PlasmaTherm/Deep Silicon Etcher) added section for Edge-Bead removal of PR etc Tag: Visual edit
- 11:27, 24 November 2021 diff hist +164 m Photolithography - Improving Adhesion Photoresist Adhesion mentioned lift-off delam Tag: Visual edit
- 11:25, 24 November 2021 diff hist +26 m Lithography Recipes →General Photolithography Techniques Tag: Visual edit
- 11:24, 24 November 2021 diff hist +180 Lithography Recipes added General Photolitho section to TOC Tag: Visual edit
- 11:22, 24 November 2021 diff hist +1,309 N Photolithography - Manual Edge-Bead Removal Techniques added razor, EBR100 and lithographic methods Tag: Visual edit
- 11:12, 24 November 2021 diff hist 0 m Lithography Recipes →General Photolithography Techniques: changed linked page title Tag: Visual edit
- 11:12, 24 November 2021 diff hist 0 m Photolithography - Improving Adhesion Photoresist Adhesion John d moved page Photolithography - HMDS Process for Improving Adhesion to Photolithography - Improving Adhesion Photoresist Adhesion without leaving a redirect: more generalized page title
- 11:11, 24 November 2021 diff hist +1,119 N Photolithography - Improving Adhesion Photoresist Adhesion added Underlayers for PR adhesion Tag: Visual edit
- 11:05, 24 November 2021 diff hist +447 Lithography Recipes Added "General Photlith techniques" section and links to 2 pages Tag: Visual edit
- 21:43, 22 November 2021 diff hist +938 Process Group - Billing Instructions added "Billing rates" section current Tag: Visual edit
- 13:45, 22 November 2021 diff hist +7 N Old Deposition Data - NastaziaM 2021-11-22 Created page with "Testing" Tag: Visual edit
- 13:45, 22 November 2021 diff hist +31 Nanofab Staff Internal Pages →Process Group: link to old dep data Tag: Visual edit
- 15:09, 18 November 2021 diff hist +527 Surface Analysis (KLA/Tencor Surfscan) added exmaple of low particle count Tag: Visual edit
- 15:07, 18 November 2021 diff hist +44 N File:Surfscan Low-Particle Example - G2.png current
- 15:05, 18 November 2021 diff hist +44 N File:Surfscan Low-Particle Example - G4.png current
- 14:35, 15 November 2021 diff hist +207 Logitech WBS7 - Procedure for Wax Mounting with bulk Crystalbond Stick added POLOS cleaning step Tag: Visual edit
- 14:33, 15 November 2021 diff hist +172 Logitech WBS7 - Procedure for Wax Mounting with bulk Crystalbond Stick link to Logitech Wafer Bonder Tag: Visual edit
- 08:43, 12 November 2021 diff hist +379 KLayout Design Tips force TOC at top, minor updates
- 08:29, 12 November 2021 diff hist +338 Maskless Aligner (Heidelberg MLA150) "updates to training video" links below video training Tag: Visual edit
- 12:23, 11 November 2021 diff hist +1,060 ASML Stepper 3 Standard Operating Procedure →Running a focus and/or exposure matrix: discussion of "process window" and "tolerance" Tag: Visual edit
- 16:47, 4 November 2021 diff hist -181 Template:Announcements Removed fl-icp
- 11:17, 4 November 2021 diff hist +377 PECVD Recipes →Cleaning Recipes (PECVD #2): added cleaning times Tag: Visual edit
- 11:04, 4 November 2021 diff hist +91 m PECVD 2 (Advanced Vacuum) →About: link to LSNitride data Tag: Visual edit
- 11:03, 4 November 2021 diff hist +179 PECVD 2 (Advanced Vacuum) →About: separated specs into sub-sections Tag: Visual edit
- 10:53, 4 November 2021 diff hist -1 m Template:Announcements
- 10:53, 4 November 2021 diff hist +181 Template:Announcements FL-ICP down
- 10:45, 4 November 2021 diff hist +90 Stepper 3 (ASML DUV) →Process Information: added Max wafer thickness Tag: Visual edit
- 12:08, 1 November 2021 diff hist +63 Resistivity Mapper (CDE RESMAP) added CSV export Tag: Visual edit
- 08:58, 1 November 2021 diff hist +392 MLA150 - Troubleshooting →Unexpected Behavior: moved to top. Added Reconverting CAD file. Tag: Visual edit
- 08:51, 1 November 2021 diff hist 0 File:MLA Quarter-Wafer Alignment.jpg John d uploaded a new version of File:MLA Quarter-Wafer Alignment.jpg current
- 11:21, 28 October 2021 diff hist +213 Lift-Off with DUV Imaging + PMGI Underlayer →Process Limits: suggest LOL, PMGI double-spin etc. Tag: Visual edit
- 21:51, 27 October 2021 diff hist -5 m ASML Stepper 3 Error Recovery, Troubleshooting and Calibration corrected max. expansion to 200pm (current machine setting) Tag: Visual edit
- 21:49, 27 October 2021 diff hist +837 ASML Stepper 3 Error Recovery, Troubleshooting and Calibration added Wafer Expansion workaround Tag: Visual edit
- 12:15, 22 October 2021 diff hist +229 N Template:StaffInfoSecondary DJ Copy of NickL's "StaffInfoSecondary" template
- 12:13, 22 October 2021 diff hist +10,286 N Template:Tool2 copy of NickL's "Tool2" template
- 12:12, 22 October 2021 diff hist +659 N Template:StaffInfo DJ copy of original StaffInfo tempalte
- 11:42, 22 October 2021 diff hist +183 Template:StaffInfo added descriptive info about this template. current
- 11:20, 22 October 2021 diff hist +193 Services →Important Info on Fabrication Services: added link to publications policy Tag: Visual edit
- 17:01, 21 October 2021 diff hist -359 Template:Announcements deleted wifi maint.
- 07:22, 19 October 2021 diff hist +359 Template:Announcements wifi maint. oct 21 6a
- 16:25, 12 October 2021 diff hist +567 Digital Microscope (Olympus DSX1000) updated description Tag: Visual edit
- 11:50, 12 October 2021 diff hist +250 Wet Benches →Wafer Toxic Corrosive Benches: added photo of the various wafer holders Tag: Visual edit
- 11:49, 12 October 2021 diff hist +75 N File:Bay 4 toxic Corrosive - wafer sample holders - IMG 4243.jpg current
- 09:21, 12 October 2021 diff hist -1 m Template:Announcements
- 09:20, 12 October 2021 diff hist -235 Template:Announcements deleted Microscope service
- 17:33, 11 October 2021 diff hist +39 COVID-19 User Policies →NanoFab Policies: mentioned that masks are provided, for Thermo-Fischer vendor Tag: Visual edit
- 14:01, 8 October 2021 diff hist +293 ICP Etching Recipes →InP Ridge Etch (Oxford ICP Etcher): links to PDFs of etch characterizations Tag: Visual edit
- 13:59, 8 October 2021 diff hist +111 N File:Oxford Etcher - InP Ridge Etch using Oxford PlasmaPro 100 Cobra - 2021-09-08.pdf Oxford Etcher - InP Ridge Etch using Oxford PlasmaPro 100 Cobra - 2021-09-08 Ning Cao, 2021-09-08
- 13:55, 8 October 2021 diff hist +93 N File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26 Ning Cao
- 13:53, 8 October 2021 diff hist +128 Dry Etching Recipes link to Oxford InP/PnGaAsP recipes Tag: Visual edit
- 16:23, 7 October 2021 diff hist +253 Template:Announcements microscopy tech service
- 09:54, 7 October 2021 diff hist 0 m Stepper 3 (ASML DUV) →Design & Fabrication Tools: fix indent Tag: Visual edit: Switched
- 09:53, 7 October 2021 diff hist +132 Stepper 3 (ASML DUV) →Operating Procedures: added Mask Making to "Design/Fab tools" Tag: Visual edit
- 09:36, 7 October 2021 diff hist +45 Calculators + Utilities →Python Scripts: "pythonXY" --> "Spyder" Tag: Visual edit
- 10:39, 4 October 2021 diff hist -264 Template:Announcements deleted ASML PM
- 17:13, 1 October 2021 diff hist +7 m Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) →Detailed Specifications Tag: Visual edit
- 17:12, 1 October 2021 diff hist +318 Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) →Detailed Specifications: mentioned 5mm exlcusion & wafers breaking Tag: Visual edit
- 17:10, 1 October 2021 diff hist +289 Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) added small-sample mounting notes Tag: Visual edit
- 17:07, 1 October 2021 diff hist -941 Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) deleted old mounting/Bosch process info Tag: Visual edit
- 08:00, 30 September 2021 diff hist -1 m Template:Announcements
- 08:00, 30 September 2021 diff hist -122 Template:Announcements Oxford ICP
- 21:30, 29 September 2021 diff hist -7 m Template:News →Oxford PlasmaPro ICP Etcher Cobra installed
- 21:29, 29 September 2021 diff hist -10 m Template:News
- 16:09, 29 September 2021 diff hist -23 m Maskless Aligner (Heidelberg MLA150) fixed HIMT link Tag: Visual edit
- 12:13, 29 September 2021 diff hist +22 m ICP Etching Recipes →SiO2 Etching (Fluorine ICP Etcher): listed etch gasses used Tag: Visual edit
- 11:59, 29 September 2021 diff hist +143 Oxford ICP Etcher (PlasmaPro 100 Cobra) →Detailed Specifications: updated ICP/RF powers Tag: Visual edit
- 11:27, 29 September 2021 diff hist +475 Template:News ADDED OXFROD ICP etch
- 11:19, 29 September 2021 diff hist +24 Oxford ICP Etcher (PlasmaPro 100 Cobra) updates to allowed materials Tag: Visual edit
- 10:45, 29 September 2021 diff hist +124 Oxford ICP Etcher (PlasmaPro 100 Cobra) →Detailed Specifications: added image, notes on substrate materials "discuss with staff" Tag: Visual edit
- 10:42, 29 September 2021 diff hist 0 File:OxfordPlasmaPro.jpg John d uploaded a new version of File:OxfordPlasmaPro.jpg current
- 10:41, 29 September 2021 diff hist +36 N File:OxfordPlasmaPro.jpg Photo from User Manual
- 19:19, 28 September 2021 diff hist +15 m MLA150 - Troubleshooting →Aligning to a quarter-wafer Tag: Visual edit
- 19:18, 28 September 2021 diff hist +182 MLA150 - Troubleshooting →Aligning to a quarter-wafer: inserted schematic Tag: Visual edit
- 19:16, 28 September 2021 diff hist +68 N File:MLA Quarter-Wafer Alignment.jpg
- 19:01, 28 September 2021 diff hist +183 MLA150 - Troubleshooting →Aligning to a quarter-wafer: minor description update Tag: Visual edit
- 18:57, 28 September 2021 diff hist +2,034 MLA150 - Troubleshooting added ALigning to a Quarter Wafer Tag: Visual edit
- 21:39, 27 September 2021 diff hist +2 m MLA150 - CAD Files and Templates Tag: Visual edit
- 21:39, 27 September 2021 diff hist +23 m MLA150 - CAD Files and Templates →Resolution and Calibration Patterns Tag: Visual edit
- 21:37, 27 September 2021 diff hist -1 m Maskless Aligner (Heidelberg MLA150) →Troubleshooting & Known Bugs
- 21:36, 27 September 2021 diff hist +37 m Maskless Aligner (Heidelberg MLA150) →Detailed Specifications Tag: Visual edit
- 21:35, 27 September 2021 diff hist +105 Maskless Aligner (Heidelberg MLA150) →Design Tools/Info: renaming/reorg for clarify Tag: Visual edit: Switched
- 17:02, 27 September 2021 diff hist +60 ICP Etching Recipes →Photoresist & ARC (Fluorine ICP Etcher): subheadings for BARC and PR strip Tag: Visual edit
- 22:10, 23 September 2021 diff hist -44 Template:Publications →Highly Selective and Vertical Etch of Silicon Dioxide using Ruthenium Films as an Etch Mask: fixed FL-ICP link
- 15:57, 23 September 2021 diff hist +91 Template:Announcements wifi update
- 10:26, 23 September 2021 diff hist -83 Dicing Saw (ADT) →Detailed Specifications: deleted old SOP, Lee's SOP only Tag: Visual edit
- 10:14, 23 September 2021 diff hist -64 Dicing Saw (ADT) →Recipes: corrected link to recipes Tag: Visual edit
- 10:11, 23 September 2021 diff hist +17 Packaging Recipes →Dicing Saw Recipes (ADT 7100): link to Thermocarbon website Tag: Visual edit
- 17:25, 21 September 2021 diff hist +68 Calculators + Utilities →Example CAD File: GDS version of CAD Tutorial Tag: Visual edit
- 17:23, 21 September 2021 diff hist +27 N File:CAD Tutorial for ASML Reticle v1 GDS.gds current
- 17:21, 21 September 2021 diff hist -1,195 Calculators + Utilities →KLayout: moved KLayout tips to separate Klayout tips page Tag: Visual edit
- 17:20, 21 September 2021 diff hist +1,952 KLayout Design Tips pasted more tips from Calc+Utilities page Tag: Visual edit
- 17:08, 21 September 2021 diff hist +374 Calculators + Utilities →Material Parameters: added Lesker links Tag: Visual edit
- 17:04, 21 September 2021 diff hist +302 Calculators + Utilities →KLayout: minor updates to KLayout / Circles Tag: Visual edit
- 16:02, 21 September 2021 diff hist -168 Calculators + Utilities →L-Edit: updated to ECE's license Tag: Visual edit
- 17:32, 20 September 2021 diff hist +23 m Template:Announcements
- 17:32, 20 September 2021 diff hist +253 Template:Announcements UCSB netowrk problems
- 14:18, 11 September 2021 diff hist +1 Dry Etching Recipes FL-ICP: SiN = A Tag: Visual edit
- 21:44, 10 September 2021 diff hist +381 Sputter 5 (AJA ATC 2200-V) link to sputter 3/4 procedures, link to SUM page for targets, and ToolInfo toolID added Tag: Visual edit
- 21:36, 10 September 2021 diff hist +62 m Sputter 3 (AJA ATC 2000-F) →Materials Table: minor cleanup Tag: Visual edit
- 21:34, 10 September 2021 diff hist +290 Sputter 4 (AJA ATC 2200-V) link to recipes page, rearranged specs, materials at bottom Tag: Visual edit
- 17:07, 9 September 2021 diff hist +1,173 Stepper Recipes linked to PR datasheets Tag: Visual edit
- 15:59, 9 September 2021 diff hist +67 Stepper 2 (AutoStep 200) move mask-making to "process info" Tag: Visual edit
- 15:40, 9 September 2021 diff hist +687 Stepper 2 (AutoStep 200) →Process Information: aded CAD files section Tag: Visual edit
- 15:38, 9 September 2021 diff hist +68 N File:GCA Local Alignment Mark Dotted.gds current
- 15:36, 9 September 2021 diff hist +48 N File:GCA Local Alignment Mark.gds current
- 15:31, 9 September 2021 diff hist +12 Stepper 1 (GCA 6300) →Process Information: added CAD Files heading Tag: Visual edit
- 15:29, 9 September 2021 diff hist +522 Stepper 1 (GCA 6300) →Process Information: links to Photomask & Alignment CAD files Tag: Visual edit
- 15:27, 9 September 2021 diff hist +46 N File:GCA Global Mark.gds current
- 15:19, 8 September 2021 diff hist +650 Template:Announcements added MikeS's Stepper 1+2 PM's
- 22:39, 7 September 2021 diff hist +54 Template:Announcements →New COVID Protocols: link to full policies
- 16:13, 7 September 2021 diff hist +156 Stepper 3 (ASML DUV) reorganization Tag: Visual edit
- 16:04, 7 September 2021 diff hist +380 Template:Announcements Aidan's fire alarm email
- 16:03, 7 September 2021 diff hist +270 Template:Announcements ASML PM Feb March 8th
- 15:00, 3 September 2021 diff hist -28 Oxford ICP Etcher (PlasmaPro 100 Cobra) →Recipes: corrected link to recipes Tag: Visual edit
- 14:12, 3 September 2021 diff hist +48 Dry Etching Recipes corrected Oxford link Tag: Visual edit
- 14:10, 3 September 2021 diff hist +705 ICP Etching Recipes Added Oxfrod ICP section and placeholder recipes Tag: Visual edit
- 14:04, 3 September 2021 diff hist +360 m Dry Etching Recipes corrected Row Bg colors
- 13:58, 3 September 2021 diff hist +973 Dry Etching Recipes Updated formatting- smaller font for model #, header colors
- 13:41, 3 September 2021 diff hist +231 Dry Etching Recipes inserted Oxford ICP column Tag: Visual edit
- 13:38, 3 September 2021 diff hist +2,774 N Oxford ICP Etcher (PlasmaPro 100 Cobra) first attempt at page
- 13:33, 3 September 2021 diff hist -4 m DSEIII (PlasmaTherm/Deep Silicon Etcher) corrected header level Tag: Visual edit
- 13:14, 3 September 2021 diff hist +359 Laser Etch Monitoring →Specific Procedures: Added Oxford Laser Mon Tag: Visual edit
- 13:13, 3 September 2021 diff hist +40 Tool List →ICP-RIE: link to Oxford ICP new page Tag: Visual edit
- 12:55, 3 September 2021 diff hist 0 File:Annotated PR etch - Om1000 03 - ARC + Cl + PR etch v1.jpg John d uploaded a new version of File:Annotated PR etch - Om1000 03 - ARC + Cl + PR etch v1.jpg current
- 09:35, 30 August 2021 diff hist -729 Template:Announcements deleted aidan's announcements
- 14:47, 27 August 2021 diff hist +299 Microscopes added Filmetrics F40-UV Tag: Visual edit
- 14:43, 27 August 2021 diff hist +139 Microscopes →Procedures & Tools: General-Use vs. Training-Required sections Tag: Visual edit
- 10:25, 26 August 2021 diff hist +1 m Services →Other U.C. Campuses: indent Attachment A
- 10:25, 26 August 2021 diff hist 0 m Services →Other U.C. Campuses: indent Attachment A
- 10:24, 26 August 2021 diff hist -8 m Services →Other U.C> Campuses: removed redlink to questionnaire, →Fabrication Services by NanoFab Staff: minor wording/formatting Tag: Visual edit
- 08:34, 26 August 2021 diff hist +135 Process Group - Remote Fabrication Jobs direct link to Fab Svc wall Tag: Visual edit
- 08:21, 26 August 2021 diff hist +143 Services →Fabrication Services by NanoFab Staff: formatting updates Tag: Visual edit: Switched
- 14:47, 24 August 2021 diff hist +30 PECVD 2 (Advanced Vacuum) moved recipes to bottom (like other pages) Tag: Visual edit
- 14:46, 24 August 2021 diff hist +8 PECVD 1 (PlasmaTherm 790) →Recipes & Process Data: renamed to Recipes and Historical Tag: Visual edit
- 14:45, 24 August 2021 diff hist +40 PECVD 2 (Advanced Vacuum) →Recipes: renamed to Recipes & Historical Tag: Visual edit
- 15:05, 23 August 2021 diff hist +81 Template:Announcements slashes on users
- 15:03, 23 August 2021 diff hist +6 m Template:Announcements changed CDA to Aidan
- 15:03, 23 August 2021 diff hist +365 Template:Announcements CDA repair closures