- 22:09, 13 September 2020 diff hist +230 Suss Aligners (SUSS MJB-3) link to recipes Tag: Visual edit
- 22:06, 13 September 2020 diff hist +1,114 N Maskless Aligner (Heidelberg MLA150) initial page with placeholders
- 21:56, 13 September 2020 diff hist +42 Tool List →Other Patterning Systems: Link to Maskless Aligner (Heidelberg MLA150) Tag: Visual edit
- 21:54, 13 September 2020 diff hist +51 Dan Read →Tools: Added Raith Velion Tag: Visual edit
- 21:40, 13 September 2020 diff hist +86 Template:Tool added Dan Read contact info
- 21:36, 13 September 2020 diff hist +12 Template:Tool →Arguments with Specific Values: added Dan Read
- 21:34, 13 September 2020 diff hist +126 Template:StaffInfo link to Tool template page for editing staff info
- 21:33, 13 September 2020 diff hist +187 Template:Staff link to Tool Tempalte in documentation current
- 21:25, 13 September 2020 diff hist +169 Lithography Recipes linked to tools in header titles Tag: Visual edit
- 21:15, 13 September 2020 diff hist +137 Focused Ion-Beam Lithography (Raith Velion) linked to Recipes page Tag: Visual edit
- 21:14, 13 September 2020 diff hist +80 Lithography Recipes added Raith Velion section, added model to EBL section title Tag: Visual edit
- 21:12, 13 September 2020 diff hist +1,794 N Focused Ion-Beam Lithography (Raith Velion) initial page, copy/pasted the JEOL EBL page
- 21:08, 13 September 2020 diff hist -35 m E-Beam Lithography System (JEOL JBX-6300FS) deleted erroneous fiels in {tool} template
- 21:06, 13 September 2020 diff hist +49 Tool List →Other Patterning Systems: Added Raith Velion link Tag: Visual edit
- 21:05, 13 September 2020 diff hist +81 Tool List →Lithography: added FEI Sirion Nabity Tag: Visual edit
- 15:39, 13 September 2020 diff hist +1,147 COVID-19 User Policies Initial links for files - files not uploaded yet Tag: Visual edit
- 14:43, 13 September 2020 diff hist +192 N COVID-19 User Policies Initial page Tag: Visual edit
- 10:42, 8 September 2020 diff hist +1 m PECVD 1 (PlasmaTherm 790) →Recipes & Process Data Tag: Visual edit
- 10:41, 8 September 2020 diff hist -7 m PECVD 1 (PlasmaTherm 790) →Recipes & Process Information: change to Process Data Tag: Visual edit
- 10:41, 8 September 2020 diff hist +206 PECVD 1 (PlasmaTherm 790) link to recipes and data Tag: Visual edit
- 10:34, 8 September 2020 diff hist -129 m Template:Announcements removed labor day
- 14:27, 1 September 2020 diff hist 0 File:UCSB Service Agreement.pdf John d uploaded a new version of File:UCSB Service Agreement.pdf
- 14:21, 1 September 2020 diff hist 0 File:Facility-Use-MOU---Intercampus-UC-User.pdf John d uploaded a new version of File:Facility-Use-MOU---Intercampus-UC-User.pdf
- 21:30, 31 August 2020 diff hist +129 Template:Announcements labor day closure
- 11:47, 26 August 2020 diff hist +453 N S-Cubed Flexi - Operating Procedure initial secitons, draft only Tag: Visual edit
- 11:42, 26 August 2020 diff hist +238 Automated Coat/Develop System (S-Cubed Flexi) added link to SOP Tag: Visual edit
- 13:33, 24 August 2020 diff hist -551 m Template:Announcements deleted lab shutdown
- 12:17, 20 August 2020 diff hist +325 ICP Etch 1 (Panasonic E646V) link to recipes page Tag: Visual edit
- 14:23, 19 August 2020 diff hist +348 Services added Agreement "Attachment A" Tag: Visual edit
- 14:22, 19 August 2020 diff hist +87 N File:Attachment A - UCSB Master Facilities Use Agreement Labs.pdf Facilities/Service Agreement - attachment listing UCSB facilities covered
- 06:51, 19 August 2020 diff hist +386 Template:Announcements addd lab shutdown, remove ASML
- 15:06, 18 August 2020 diff hist +6 m CAIBE (Oxford Ion Mill) →Recipes: bolded recipe page li nk Tag: Visual edit
- 12:27, 18 August 2020 diff hist +45 Contact Alignment Recipes →Negative Resist (MA-6): update MA-6 NegPR flood expose Tag: Visual edit
- 12:24, 18 August 2020 diff hist +303 Contact Alignment Recipes updated powers again Tag: Visual edit
- 07:42, 18 August 2020 diff hist +224 Contact Alignment Recipes →Suss Aligners (SUSS MJB-3): updated Channel powers according ot LeeS Tag: Visual edit
- 21:29, 12 August 2020 diff hist -32 m Unaxis wafer coating procedure typos in units (nm/µm/mm), minor formatting current Tag: Visual edit
- 11:23, 11 August 2020 diff hist +86 Logitech WBS7 - Procedure for Wax Mounting with bulk Crystalbond Stick clean glass plate if wax present Tag: Visual edit
- 11:21, 11 August 2020 diff hist +421 Logitech WBS7 - Procedure for Wax Mounting with bulk Crystalbond Stick updated open/close procedure Tag: Visual edit
- 10:09, 11 August 2020 diff hist +45 m Logitech WBS7 - Procedure for Wax Mounting with bulk Crystalbond Stick unload step Tag: Visual edit
- 09:24, 11 August 2020 diff hist -14 Logitech WBS7 - Procedure for Wax Mounting with bulk Crystalbond Stick formatting to match tool menus Tag: Visual edit
- 08:12, 11 August 2020 diff hist +108 m Logitech WBS7 - Procedure for Wax Mounting with Spin-On Crystalbond attributed to Don Freeborn current Tag: Visual edit
- 07:26, 9 August 2020 diff hist +3 m Probe Station: I-V Curves with Keithley 2400 and Python Script image adjust
- 07:23, 9 August 2020 diff hist -30 m Probe Station: I-V Curves with Keithley 2400 and Python Script image adjustments Tag: Visual edit
- 07:22, 9 August 2020 diff hist +492 Probe Station: I-V Curves with Keithley 2400 and Python Script added screenshots Tag: Visual edit
- 07:21, 9 August 2020 diff hist +45 N File:Python Keithley I-V Sweep v3 icon.png current
- 07:19, 9 August 2020 diff hist +26 N File:Python Spyder - Run Button.png current
- 07:18, 9 August 2020 diff hist +44 N File:Python Keithely I-V - user settings lines.png current
- 07:16, 9 August 2020 diff hist +30 N File:Python Spyder 3.7 (anacoda) icon.png current
- 07:14, 9 August 2020 diff hist +1 m Probe Station: I-V Curves with Keithley 2400 and Python Script
- 07:14, 9 August 2020 diff hist -1 Probe Station: I-V Curves with Keithley 2400 and Python Script
- 07:14, 9 August 2020 diff hist +2,079 N Probe Station: I-V Curves with Keithley 2400 and Python Script initial procedure for Python I-V curves Tag: Visual edit
- 06:37, 9 August 2020 diff hist +143 Probe Station & Curve Tracer →Operation Procedures & Manuals: link to Python I-V Curves Tag: Visual edit
- 17:10, 29 July 2020 diff hist -16 m Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) →Detailed Specifications: update LEP description Tag: Visual edit
- 17:09, 29 July 2020 diff hist 0 m Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) →Recipes: spelling Tag: Visual edit
- 17:08, 29 July 2020 diff hist +6 m Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) →Recipes: bolded Tag: Visual edit
- 16:00, 27 July 2020 diff hist +6 m Staff List highlight director, like other groups Tag: Visual edit
- 09:23, 27 July 2020 diff hist +30 m Goniometer (Rame-Hart A-100) - Operating Procedure →Measurement Procedure: image caption Tag: Visual edit
- 09:23, 27 July 2020 diff hist +2 m Goniometer (Rame-Hart A-100) - Operating Procedure →Measurement Procedure: indent, spacing
- 09:21, 27 July 2020 diff hist -28 Goniometer (Rame-Hart A-100) - Operating Procedure image sizing Tag: Visual edit
- 09:20, 27 July 2020 diff hist +821 N Goniometer (Rame-Hart A-100) - Operating Procedure initial page, mostly copied from "NRL Contact Angle Goniometer - Owners Manual.pdf" Tag: Visual edit
- 09:18, 27 July 2020 diff hist +33 N File:Goniometer - Reflective Sample Illustration.png current
- 09:08, 27 July 2020 diff hist +101 N File:Goniometer (Rame-Hart A-100) - Steps for Measuring v1.png current
- 08:55, 27 July 2020 diff hist +54 N File:Goniometer (Rame-Hart A-100) - Annotated Photo.png current
- 13:38, 26 July 2020 diff hist +29 m MVD - Wafer Coating - Process Traveler →Removal: of FDTS Coating: added PEii etch params current Tag: Visual edit
- 13:37, 26 July 2020 diff hist +29 MVD - Wafer Coating - Process Traveler link to new goniometer page Tag: Visual edit
- 13:36, 26 July 2020 diff hist +29 m Thermal Processing Recipes link to new goniometer page Tag: Visual edit
- 13:36, 26 July 2020 diff hist +55 Tool List →Inspection, Test and Characterization: link to new goniometer page Tag: Visual edit
- 13:35, 26 July 2020 diff hist +42 N Goniometer John d moved page Goniometer to Goniometer (Rame-Hart A-100): added mfg./model into name, like other tools current Tag: New redirect
- 20:55, 25 July 2020 diff hist +22 m ASML Stepper 3 Standard Operating Procedure →Reticle Unloading and Loading Tag: Visual edit
- 20:52, 25 July 2020 diff hist +181 m ASML Stepper 3 Standard Operating Procedure →Running a Job – Normal operation: added unload reticle Tag: Visual edit
- 06:45, 25 July 2020 diff hist +60 m ICP Etching Recipes →Recipe Variations: description of slanted etching doc Tag: Visual edit
- 22:13, 24 July 2020 diff hist +25 ICP Etching Recipes →SiO2 Etching: added credit for Bill Mitchell Tag: Visual edit
- 10:27, 24 July 2020 diff hist +205 ICP Etching Recipes →DSEIII_(PlasmaTherm/Deep_Silicon_Etcher): added actual Recipe names from teh tool Tag: Visual edit
- 09:22, 24 July 2020 diff hist +7 Lithography Recipes →Chemicals Stocked + Datasheets: clarified THMR PR documents Tag: Visual edit
- 07:54, 24 July 2020 diff hist +1 m ICP Etch 2 (Panasonic E626I) put ICP2 recipes first Tag: Visual edit
- 06:56, 24 July 2020 diff hist +27 m ICP Etching Recipes →DSEIII_(PlasmaTherm/Deep_Silicon_Etcher) Tag: Visual edit
- 06:55, 24 July 2020 diff hist +434 ICP Etching Recipes →High Rate Bosch Etch (DSEIII): added descriptions to the two recipes Tag: Visual edit
- 10:20, 23 July 2020 diff hist +717 N MVD - Wafer Coating - Process Traveler added procedure from BrianT's PDF Tag: Visual edit
- 10:15, 23 July 2020 diff hist +77 Molecular Vapor Deposition →Recipes: link to new process traveler Tag: Visual edit
- 10:08, 23 July 2020 diff hist +6 DSEIII (PlasmaTherm/Deep Silicon Etcher) →Documentation: bolded Tag: Visual edit
- 10:08, 23 July 2020 diff hist +260 DSEIII (PlasmaTherm/Deep Silicon Etcher) added allowed materisl: Al2O3, Al, Crystalbond wax, wafer size and clamp Tag: Visual edit
- 08:53, 21 July 2020 diff hist +8 m Dicing Saw (ADT) →Recipes: minor formatting Tag: Visual edit
- 19:22, 20 July 2020 diff hist +316 Template:Publications added Warren's paper
- 11:55, 20 July 2020 diff hist +528 m Frequently Asked Questions →Cell Phone Calls: Section on forcing calls through Wifi, not Cellular. Tag: Visual edit
- 16:35, 19 July 2020 diff hist 0 m Template:Announcements corrected date, COVID on top
- 14:50, 19 July 2020 diff hist +166 Template:Announcements asml maint
- 13:33, 18 July 2020 diff hist +100 m Chemical List →Material Safety Datasheets: minor comment Tag: Visual edit
- 13:25, 18 July 2020 diff hist -34 m Chemical List →Inventory List: updated photolith cehmicals URL Tag: Visual edit
- 00:20, 16 July 2020 diff hist +175 Unaxis wafer coating procedure link to recipes page Tag: Visual edit
- 00:18, 16 July 2020 diff hist -12 m Unaxis wafer coating procedure →Unaxis SiN LS @250°C deposition: unbold
- 00:17, 16 July 2020 diff hist +309 m Unaxis wafer coating procedure only edit dep. time Tag: Visual edit
- 00:13, 16 July 2020 diff hist +477 Unaxis wafer coating procedure notes about 0.5µm max. dep, and particle counting Tag: Visual edit
- 00:08, 16 July 2020 diff hist +111 ICP-PECVD (Unaxis VLR) →Documentation: redlink the SOP, explain the purpose of the "procedure" Tag: Visual edit
- 09:57, 14 July 2020 diff hist +338 m GoPro Hero8 Black (Internal) →Saving the Video to your computer: how to delete files Tag: Visual edit
- 09:55, 14 July 2020 diff hist +27 N File:Forward Delete Button.png current
- 09:52, 14 July 2020 diff hist +46 N File:GoPro HERO8 Black Instructions - Mac save to computer 2.png current
- 09:14, 14 July 2020 diff hist -25 m GoPro Hero8 Black (Internal) →Saving the Video to your computer: simplified Mac instrucitons Tag: Visual edit
- 09:12, 14 July 2020 diff hist +224 GoPro Hero8 Black (Internal) →Saving the Video to your computer: added windows insturctions, TBD on "Upload to Web" Tag: Visual edit
- 15:29, 6 July 2020 diff hist -198 Template:Announcements deleted 4th July
- 16:35, 5 July 2020 diff hist +174 m Stepper 3 (ASML DUV) →Operating Procedures: link to FEM sub-section Tag: Visual edit