Difference between revisions of "Tool List"
Jump to navigation
Jump to search
m (→Electrical Analysis: fix QFI link) |
(→Optical Microscopy: link to MJB-IR IR scope) |
||
(9 intermediate revisions by the same user not shown) | |||
Line 12: | Line 12: | ||
=====Contact Aligners (Optical Exposure)===== |
=====Contact Aligners (Optical Exposure)===== |
||
− | *[[Suss Aligners (SUSS MJB-3)]] |
+ | *[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]] |
*[[Contact Aligner (SUSS MA-6)]] |
*[[Contact Aligner (SUSS MA-6)]] |
||
*[[DUV Flood Expose]] |
*[[DUV Flood Expose]] |
||
Line 19: | Line 19: | ||
*[[E-Beam Lithography System (JEOL JBX-6300FS)]] |
*[[E-Beam Lithography System (JEOL JBX-6300FS)]] |
||
− | *[[ |
+ | *[[SEM 1 (JEOL IT800SHL)|E-Beam Lithography (Nabity v9)]] |
*[[Focused Ion-Beam Lithography (Raith Velion)]] |
*[[Focused Ion-Beam Lithography (Raith Velion)]] |
||
*[[Maskless Aligner (Heidelberg MLA150)]] |
*[[Maskless Aligner (Heidelberg MLA150)]] |
||
Line 110: | Line 110: | ||
=====ICP-RIE===== |
=====ICP-RIE===== |
||
− | *[[ICP Etch 1 (Panasonic |
+ | *[[ICP Etch 1 (Panasonic E646V)]] |
− | *[[ICP Etch 2 (Panasonic |
+ | *[[ICP Etch 2 (Panasonic E626I)]] |
*[[ICP-Etch (Unaxis VLR)]] |
*[[ICP-Etch (Unaxis VLR)]] |
||
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]] |
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]] |
||
Line 175: | Line 175: | ||
=Packaging= |
=Packaging= |
||
+ | ''Back-end Fabrication Tools'' |
||
{| |
{| |
||
| |
| |
||
Line 180: | Line 181: | ||
*[[Dicing Saw (ADT)]] |
*[[Dicing Saw (ADT)]] |
||
− | *[[Wafer Cleaver (PELCO Flip-Scribe)|Wafer Cleaver (PELCO Flipscribe)]] |
+ | *[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]] |
+ | *[[Automated Wafer Cleaver (Loomis LSD-155LT)]] |
||
====Other Packaging==== |
====Other Packaging==== |
||
Line 194: | Line 196: | ||
|} |
|} |
||
− | = |
+ | =Measurement & Characterization= |
+ | ''[https://en.wikipedia.org/wiki/Metrology Metrology], Electrical/Optical Testing and Thin-Film/Materials [https://en.wikipedia.org/wiki/Characterization_(materials_science) Characterization] tools'' |
||
{| |
{| |
||
|- valign="top" |
|- valign="top" |
||
Line 205: | Line 208: | ||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
||
+ | *[[Suss Aligners (SUSS MJB-3)#Backside Alignment|Near-IR Inspection Scope (MJB-IR)]] |
||
=====Electron Microscopy===== |
=====Electron Microscopy===== |
||
− | *[[ |
+ | *[[SEM 1 (JEOL IT800SHL)]] |
− | *[[Field Emission SEM 2 (JEOL |
+ | *[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]] |
*[[SEM Sample Coater (Hummer)]] |
*[[SEM Sample Coater (Hummer)]] |
||
Line 240: | Line 244: | ||
*[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]] |
*[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]] |
||
*[[Photoluminescence PL Setup (Custom)]] |
*[[Photoluminescence PL Setup (Custom)]] |
||
− | *[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] |
||
− | **''Surface hydrophobicity'' |
||
|- |
|- |
||
|} |
|} |
Latest revision as of 11:52, 1 March 2024
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Direct-Write Lithography
Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)Thermal Evaporation
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and CleaningEtch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Back-end Fabrication Tools
Die Singulation / Down-sizingOther Packaging |
Wafer/Die Bonding |
Measurement & Characterization
Metrology, Electrical/Optical Testing and Thin-Film/Materials Characterization tools
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Electrical Analysis
Other Properties |