User contributions
Jump to navigation
Jump to search
- 10:46, 13 July 2021 diff hist +41 N File:200um square v1.gds TESTING only - please delte current
- 13:47, 12 July 2021 diff hist +48 m Stepper Recipes →DUV-42P-6: updated etching links Tag: Visual edit
- 13:43, 12 July 2021 diff hist +16 m ICP Etching Recipes →Photoresist and ARC Etching (Panasonic 1): fixed URL link Tag: Visual edit
- 14:19, 9 July 2021 diff hist +928 Atomic Layer Deposition Recipes →Atomic Layer Deposition (Oxford FlexAL): Recipe info on Plasma, Ratios Tag: Visual edit
- 11:49, 9 July 2021 diff hist -2 Services →Other U.C. Campuses: corrected broken email link
- 16:50, 8 July 2021 diff hist +40 Autostep 200 Mask Making Guidance added magnification Tag: Visual edit
- 16:48, 8 July 2021 diff hist +5 Autostep 200 Mask Making Guidance corercted dimensions to 5x5x0.090 Tag: Visual edit
- 16:44, 8 July 2021 diff hist +163 Autostep 200 Mask Making Guidance added Plate materials/dimensions Tag: Visual edit
- 11:20, 7 July 2021 diff hist +88 Nanofab Staff Internal Pages →Process Group: added link to Supplies Costs Tag: Visual edit
- 12:55, 2 July 2021 diff hist +91 Process Group - Billing Instructions →Supplies Costs: sotrage location in notes Tag: Visual edit
- 12:53, 2 July 2021 diff hist -2 m Process Group - Billing Instructions →Supplies Charges: --> Supplies Costs Tag: Visual edit
- 12:53, 2 July 2021 diff hist +51 Process Group - Billing Instructions force TOC
- 12:45, 2 July 2021 diff hist +16 Process Group - Billing Instructions →Supplies Charges: updated prices wafers Tag: Visual edit
- 12:44, 2 July 2021 diff hist +238 Process Group - Billing Instructions added wafer costs Tag: Visual edit
- 11:51, 2 July 2021 diff hist +24 m Process Group - Billing Instructions table title row Tag: Visual edit: Switched
- 11:48, 2 July 2021 diff hist +1,068 Process Group - Billing Instructions added shipping supplies table Tag: Visual edit: Switched
- 11:39, 2 July 2021 diff hist +1,637 N Process Group - Billing Instructions added overhead charges, F&A rate etc. Tag: Visual edit
- 11:36, 2 July 2021 diff hist +27 N File:RechargeApp - 02 - F+A auto v2.png current
- 11:27, 2 July 2021 diff hist +25 N File:RechargeApp - 01 - line items for other charges.png current
- 11:21, 2 July 2021 diff hist +17 m Nanofab Staff Internal Pages Tag: Visual edit
- 11:21, 2 July 2021 diff hist +106 Nanofab Staff Internal Pages →Process Group: link to Billing Instructions Tag: Visual edit
- 23:32, 29 June 2021 diff hist +17 m Chemical List BT --> Lab Director Tag: Visual edit
- 23:31, 29 June 2021 diff hist +466 m Wet Etching Recipes KOH: added mention of "low-stress" SiN Tag: Visual edit
- 23:19, 29 June 2021 diff hist +218 Wet Etching Recipes link to Chemicals List Tag: Visual edit
- 23:09, 29 June 2021 diff hist +33 m Mechanical Polisher (Allied) recipes TBD Tag: Visual edit
- 23:04, 29 June 2021 diff hist -51 Flip-Chip Bonder (Finetech) remove incorrect phone/email tags from Tool template
- 20:35, 23 June 2021 diff hist -801 Process Group - Remote Fabrication Jobs deleted Trello, updated OnDema Tag: Visual edit
- 10:22, 23 June 2021 diff hist +904 Plasma Clean (YES EcoClean) added etch method & applications Tag: Visual edit
- 10:16, 23 June 2021 diff hist +742 Ashers (Technics PEII) →About: applicaitons section Tag: Visual edit
- 09:47, 21 June 2021 diff hist +12 Stepper Recipes →DUV-42P: corrected to 2500rpm for 60nm thick, DUV42P-6 formulation Tag: Visual edit
- 11:30, 17 June 2021 diff hist 0 m Vacuum Deposition Recipes changed IBD SiON A --> R Tag: Visual edit
- 13:46, 14 June 2021 diff hist -293 Template:Announcements ISO spray updat,e deleted ASML maint.
- 10:02, 14 June 2021 diff hist -1 m RIE Etching Recipes →Photoresist and ARC (RIE 5) current Tag: Visual edit
- 10:02, 14 June 2021 diff hist +121 Dry Etching Recipes corrected links to PR & ARC etching Tag: Visual edit
- 10:01, 14 June 2021 diff hist +256 RIE Etching Recipes →Photoresist and ARC: added tool name to header title Tag: Visual edit
- 09:59, 14 June 2021 diff hist +28 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I): corrected header titles to include "(Pan 1/2" Tag: Visual edit
- 10:41, 7 June 2021 diff hist +47 m MLA150 - Troubleshooting →Workaround Tag: Visual edit
- 10:40, 7 June 2021 diff hist +58 m MLA150 - Troubleshooting →Workaround: link to reboot prcedure
- 10:38, 7 June 2021 diff hist +1,997 MLA150 - Troubleshooting Out of Focus exposures - problem + solutions Tag: Visual edit
- 12:12, 3 June 2021 diff hist +175 Vacuum Oven (YES) added info from Brian Lingg current Tag: Visual edit
- 12:09, 3 June 2021 diff hist +114 Ovens - Overview of All Lab Ovens added YES info Tag: Visual edit
- 13:32, 2 June 2021 diff hist +25 m Stepper 3 (ASML DUV) added Model field in Tool templ.
- 13:24, 2 June 2021 diff hist +35 m Vacuum Deposition Recipes BG color of "SiN- Low stress"
- 14:13, 28 May 2021 diff hist +96 Atomic Layer Deposition Recipes →Oxford FlexAL Chamber #3: Dielectrics: started historical data seciton Tag: Visual edit
- 08:34, 27 May 2021 diff hist -2 m Editing Tutorials Tag: Visual edit
- 08:34, 27 May 2021 diff hist +831 Editing Tutorials Updating a file version Tag: Visual edit
- 08:32, 27 May 2021 diff hist 0 File:UCSB-Facilities-Use-Agreement.pdf John d uploaded a new version of File:UCSB-Facilities-Use-Agreement.pdf
- 08:32, 27 May 2021 diff hist 0 File:UCSB Service Agreement.pdf John d uploaded a new version of File:UCSB Service Agreement.pdf
- 08:25, 27 May 2021 diff hist +106 m Frequently Asked Questions →How do I get a login to the wiki?: link to Wiki admin contact page Tag: Visual edit
- 08:07, 27 May 2021 diff hist +19 Template:News →SiO2 etching, High-Aspect Ratio
- 08:05, 27 May 2021 diff hist +51 m Template:News added date to SiO2 etch article
- 08:01, 27 May 2021 diff hist +253 ICP Etching Recipes →SiO2 Etching (Fluorine ICP Etcher): link to publication Tag: Visual edit
- 07:58, 27 May 2021 diff hist +36 ICP Etching Recipes →Ru (Ruthenium) Etch (Panasonic 2): link to pub Tag: Visual edit
- 07:56, 27 May 2021 diff hist +905 Template:News Added info about Bill's SiO2 etching paper
- 07:41, 27 May 2021 diff hist +536 Template:Publications link to Bill's Ru-masked SiO2 paper
- 12:35, 26 May 2021 diff hist +149 Direct-Write Lithography Recipes →Maskless Aligner (Heidelberg MLA150): mention that any I-Line PR will work. Tag: Visual edit
- 13:26, 21 May 2021 diff hist +42 m Template:Announcements
- 13:25, 21 May 2021 diff hist +27 m Template:Announcements
- 13:24, 21 May 2021 diff hist -31 m Template:Announcements linked to new policies directly
- 13:22, 21 May 2021 diff hist +24 m COVID-19 User Policies summary at top of annoucnements Tag: Visual edit
- 15:57, 17 May 2021 diff hist 0 File:Nanofabrication Facility Project Description.xlsx John d uploaded a new version of File:Nanofabrication Facility Project Description.xlsx
- 13:06, 17 May 2021 diff hist +155 Stepper Recipes →DUV-42P: link to FL-ICP and Technics for BARC etches Tag: Visual edit
- 13:04, 17 May 2021 diff hist +526 ICP Etching Recipes →PlasmaTherm/SLR Fluorine Etcher: added BARC and PR etches Tag: Visual edit
- 12:55, 17 May 2021 diff hist +8 m Stepper Recipes →DUV-42P-6: comments on corrected spin speed Tag: Visual edit
- 12:53, 17 May 2021 diff hist +4 Stepper Recipes →DUV-42P: aDDED "-6" to the DUV42P part number Tag: Visual edit
- 12:52, 17 May 2021 diff hist +3 Lithography Recipes →Chemicals Stocked + Datasheets: corrected part number for DUV42P (added "-6") Tag: Visual edit
- 06:17, 17 May 2021 diff hist +8 Nanofab Staff Internal Pages →Process Group: moved lab Stocking to "Old" section Tag: Visual edit
- 06:15, 17 May 2021 diff hist +218 Process Group - Remote Fabrication Jobs link to OnDema.io NanoFab Workspace Tag: Visual edit
- 12:09, 11 May 2021 diff hist +4 Template:News →Wafer Polisher available: link to Lingg's page
- 12:08, 11 May 2021 diff hist +57 m Template:News →Wafer Polisher added to tool list: link to polisher wiki page
- 11:38, 11 May 2021 diff hist +34 Tool List →Wet Processing: link to Mechanical_Polisher_(Allied) Tag: Visual edit
- 11:36, 11 May 2021 diff hist +96 N File:AlliedPolisher10-1110.jpg Photo of Allied Polisher model 10-1110 ; Initial photo - cropped and color boosted current
- 11:33, 11 May 2021 diff hist +620 N Mechanical Polisher (Allied) initial Page
- 16:49, 10 May 2021 diff hist +203 Template:News Added allied polisher
- 06:56, 6 May 2021 diff hist +62 Process Group - Remote Fabrication Jobs link to Trello: UCSB Nanofab Tag: Visual edit
- 06:51, 6 May 2021 diff hist +30 m Process Group - Remote Fabrication Jobs Tag: Visual edit
- 06:50, 6 May 2021 diff hist +10 Process Group - Remote Fabrication Jobs Tag: Visual edit
- 06:50, 6 May 2021 diff hist -43 Process Group - Remote Fabrication Jobs Tag: Visual edit
- 21:34, 5 May 2021 diff hist +920 N Process Group - Remote Fabrication Jobs Trello -filter your own jobs Tag: Visual edit
- 21:33, 5 May 2021 diff hist +46 N File:Board - Search Cards - Select User.png current
- 21:30, 5 May 2021 diff hist +46 N File:Trello - Board - Search Cards.png current
- 21:27, 5 May 2021 diff hist +40 N File:Trello - Board - Show Menu.png current
- 21:22, 5 May 2021 diff hist +136 Nanofab Staff Internal Pages →Process Group: link to Remote Job Tracking Tag: Visual edit
- 09:59, 4 May 2021 diff hist +96 Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) →Recipes: mention historical data Tag: Visual edit
- 09:56, 4 May 2021 diff hist +118 ICP Etch 1 (Panasonic E646V) →Recipes: mention historical data Tag: Visual edit
- 09:55, 4 May 2021 diff hist +96 ICP Etch 2 (Panasonic E626I) →Recipes: mentioned historical data Tag: Visual edit
- 06:51, 30 April 2021 diff hist -250 Template:Announcements deleted MLA
- 23:13, 28 April 2021 diff hist -1 m Main Page minor updates
- 23:10, 28 April 2021 diff hist -600 Template:FeaturedArticle current
- 23:06, 28 April 2021 diff hist +23 Editing Tutorials →Editing an Existing Page: link to how to get a login Tag: Visual edit
- 22:56, 28 April 2021 diff hist +443 ASML Stepper 3 Error Recovery, Troubleshooting and Calibration →Common Warnings: updated warnings Tag: Visual edit
- 22:44, 28 April 2021 diff hist -22 Template:Announcements deleted ASML 4/26, added HIMT 4/29
- 12:54, 21 April 2021 diff hist +30 Laser Etch Monitor Simulation in Python author credits. current Tag: Visual edit
- 08:11, 20 April 2021 diff hist -765 Template:Announcements deleted Flu Season notice, shortened Weekly Testing article
- 08:07, 20 April 2021 diff hist +272 Template:Announcements asml service Apr 26th 2021
- 07:32, 20 April 2021 diff hist +390 Template:Announcements ASML May service
- 19:55, 16 April 2021 diff hist +175 Frequently Asked Questions →Authorship on Publications: note on process discusssions Tag: Visual edit
- 18:32, 16 April 2021 diff hist +364 Sputtering Recipes →Sputter 3 (AJA ATC 2000-F): Reduced Heading Levels below "Page Title" Tag: Visual edit
- 15:53, 16 April 2021 diff hist -190 Template:Announcements deleted "lab shutdown"
- 09:36, 16 April 2021 diff hist +84 ICP Etching Recipes →SiO2 Etching (Fluorine ICP Etcher): added ER and Sel for 50W & 200W bias Tag: Visual edit