- 15:10, 20 June 2019 diff hist +59 Stepper 1 (GCA 6300) - Standard Operating Procedure →Loading a wafer into the system Tag: Visual edit
- 14:23, 20 June 2019 diff hist -27 Stepper 2 (AutoStep 200) Operating Procedures →Reticle Loading and Unloading Tag: Visual edit
- 13:46, 20 June 2019 diff hist +4 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences →JOB Programming - FULL Tag: Visual edit
- 13:37, 20 June 2019 diff hist +4,137 N Stepper 2 (Autostep 200) - Table of Chucks, Shims, Target Thicknesses pasted table from excel Tag: Visual edit
- 13:35, 20 June 2019 diff hist +921 N Stepper 2 (Autostep 200) - Chuck Selection pasted table from excel Tag: Visual edit
- 13:28, 20 June 2019 diff hist +182 Stepper 2 (AutoStep 200) Operating Procedures →Loading a wafer into the system: links to table pages Tag: Visual edit
- 08:22, 17 June 2019 diff hist -31 Stepper 1 (GCA 6300) →Operating Procedures Tag: Visual edit
- 08:20, 17 June 2019 diff hist +2,387 GCA 6300 USer Accessible Commands commands Tag: Visual edit
- 08:09, 17 June 2019 diff hist +3 N GCA 6300 USer Accessible Commands Created page with "WIP"
- 08:09, 17 June 2019 diff hist +38 Stepper 1 (GCA 6300) →Operating Procedures Tag: Visual edit
- 08:08, 17 June 2019 diff hist +36 Stepper 1 (GCA 6300) →Operating Procedures Tag: Visual edit
- 08:07, 17 June 2019 diff hist +2,315 Autostep 200 User Accessible Commands commands Tag: Visual edit
- 08:06, 17 June 2019 diff hist +3 N Autostep 200 User Accessible Commands Created page with "WIP"
- 08:06, 17 June 2019 diff hist +4 Stepper 2 (AutoStep 200) →Operating Procedures Tag: Visual edit
- 08:05, 17 June 2019 diff hist -69 Stepper 2 (AutoStep 200) →Operating Procedures Tag: Visual edit
- 08:04, 17 June 2019 diff hist +40 Stepper 2 (AutoStep 200) Commands Tag: Visual edit
- 15:38, 13 June 2019 diff hist +38 Stepper 2 (AutoStep 200) →Operating Procedures Tag: Visual edit
- 15:37, 13 June 2019 diff hist +3 Autostep 200 Troubleshooting and Recovery wip Tag: Visual edit
- 15:36, 13 June 2019 diff hist +3 N Autostep 200 Troubleshooting and Recovery Troubleshooting and Recovery Tag: Visual edit
- 15:36, 13 June 2019 diff hist +42 Stepper 2 (AutoStep 200) Autostep Troubleshooting and Recovery Tag: Visual edit
- 15:34, 13 June 2019 diff hist +35 Stepper 2 (AutoStep 200) Troubleshooting and Recovery Tag: Visual edit
- 15:33, 13 June 2019 diff hist +3 N Troubleshooting and Recovery Troubleshooting and Recovery Tag: Visual edit
- 15:33, 13 June 2019 diff hist +35 Stepper 1 (GCA 6300) Troubleshooting and Recovery Tag: Visual edit
- 15:30, 13 June 2019 diff hist +5,471 GCA 6300 Mask Making Guidance mask layout Tag: Visual edit
- 15:28, 13 June 2019 diff hist +2,023 Autostep 200 Mask Making Guidance mask layout Tag: Visual edit
- 15:24, 13 June 2019 diff hist -75 User Accessible Commands commands current Tag: Visual edit
- 15:15, 13 June 2019 diff hist +3 N Autostep 200 Mask Making Guidance mask making guidance Tag: Visual edit
- 15:15, 13 June 2019 diff hist +71 Stepper 2 (AutoStep 200) new pages Tag: Visual edit
- 15:13, 13 June 2019 diff hist +1 Stepper 1 (GCA 6300) →Operating Procedures Tag: Visual edit
- 15:12, 13 June 2019 diff hist +4,196 GCA 6300 Mask Making Guidance mask making guidance Tag: Visual edit
- 15:10, 13 June 2019 diff hist +2,422 User Accessible Commands commands Tag: Visual edit
- 14:44, 13 June 2019 diff hist +16 N User Accessible Commands WIP Tag: Visual edit
- 14:43, 13 June 2019 diff hist +16 N GCA 6300 Mask Making Guidance WIP Tag: Visual edit
- 14:42, 13 June 2019 diff hist +67 Stepper 1 (GCA 6300) GCA 6300 MAsk MAking Guidance Tag: Visual edit
- 14:35, 13 June 2019 diff hist +114 Stepper 2 (AutoStep 200) Operating Procedures →Running a JOB - Normal Operation Tag: Visual edit
- 14:32, 13 June 2019 diff hist +290 Stepper 2 (AutoStep 200) Operating Procedures →Running a JOB - Normal Operation Tag: Visual edit
- 14:29, 13 June 2019 diff hist +58 Stepper 2 (AutoStep 200) Operating Procedures →Running a JOB - Normal Operation Tag: Visual edit
- 14:27, 13 June 2019 diff hist +7 Stepper 1 (GCA 6300) - Standard Operating Procedure →Spin coating and cleaning the back-side of wafer Tag: Visual edit
- 14:27, 13 June 2019 diff hist +169 Stepper 2 (AutoStep 200) Operating Procedures →Cleaning the back-side of wafer Tag: Visual edit
- 14:25, 13 June 2019 diff hist +161 Stepper 1 (GCA 6300) - Standard Operating Procedure →Cleaning the back-side of wafer Tag: Visual edit
- 14:22, 13 June 2019 diff hist +339 Stepper 1 (GCA 6300) - Standard Operating Procedure →Running a JOB-Normal Operation Tag: Visual edit
- 12:14, 13 June 2019 diff hist +50 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences →JOB Programming - FULL Tag: Visual edit
- 12:04, 13 June 2019 diff hist +5 Programming a Job →JOB Programming - FULL Tag: Visual edit
- 11:59, 13 June 2019 diff hist -856 Programming a Job →JOB Programming - FULL Tag: Visual edit
- 16:01, 11 June 2019 diff hist +1 Programming a Job →JOB Programing - FULL Tag: Visual edit
- 16:01, 11 June 2019 diff hist -63 Stepper 1 (GCA 6300) page Tag: Visual edit
- 16:00, 11 June 2019 diff hist +1 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences programming Tag: Visual edit
- 15:59, 11 June 2019 diff hist +224 Programming a Job programming a job Tag: Visual edit
- 15:20, 11 June 2019 diff hist +13,361 Programming a Job programming Tag: Visual edit
- 15:18, 11 June 2019 diff hist +7 N Programming a Job testing Tag: Visual edit
- 15:17, 11 June 2019 diff hist +24 Stepper 1 (GCA 6300) programing a job page Tag: Visual edit
- 15:35, 10 June 2019 diff hist +40 Stepper 1 (GCA 6300) →Operating Procedures
- 15:34, 10 June 2019 diff hist +2 Stepper 1 (GCA 6300) →Operating Procedures
- 15:33, 10 June 2019 diff hist -25 Stepper 1 (GCA 6300) →Operating Procedures
- 15:33, 10 June 2019 diff hist +46 Stepper 1 (GCA 6300) →Operating Procedures
- 15:31, 10 June 2019 diff hist +59 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences programming Tag: Visual edit
- 15:28, 10 June 2019 diff hist -3,242 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences →JOB Programing - FULL Tag: Visual edit
- 09:30, 10 June 2019 diff hist +4,810 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences →JOB Programing - FULL Tag: Visual edit
- 15:58, 6 June 2019 diff hist +11,757 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences programming Tag: Visual edit
- 15:58, 6 June 2019 diff hist -11,819 Stepper 2 (AutoStep 200) Operating Procedures corr Tag: Visual edit
- 15:56, 6 June 2019 diff hist +11,785 Stepper 2 (AutoStep 200) Operating Procedures →JOB Programing- FULL Tag: Visual edit
- 14:07, 6 June 2019 diff hist +34 Stepper 2 (AutoStep 200) Operating Procedures job programing Tag: Visual edit
- 14:01, 6 June 2019 diff hist +36 Stepper 2 (AutoStep 200) Operating Procedures →Cleaning the back-side of wafer Tag: Visual edit
- 14:00, 6 June 2019 diff hist +18 Stepper 1 (GCA 6300) - Standard Operating Procedure →Wafer Loading Tag: Visual edit
- 13:57, 6 June 2019 diff hist -9 Stepper 2 (AutoStep 200) →Standard Operating Procedures Tag: Visual edit
- 13:57, 6 June 2019 diff hist +9 Stepper 2 (AutoStep 200) →Operating Procedures Tag: Visual edit
- 13:55, 6 June 2019 diff hist +1 Stepper 2 (AutoStep 200) Operating Procedures →Running a JOB- Normal Operation Tag: Visual edit
- 13:53, 6 June 2019 diff hist -80 Stepper 2 (AutoStep 200) Operating Procedures →Running a FOCUS and\or EXPOSURE matrix Tag: Visual edit
- 11:20, 6 June 2019 diff hist +2,729 Stepper 2 (AutoStep 200) Operating Procedures →Running a FOCUS and\or EXPOSURE matrix Tag: Visual edit
- 11:19, 6 June 2019 diff hist +46 Stepper 2 (AutoStep 200) Operating Procedures EXP. matrix Tag: Visual edit
- 11:18, 6 June 2019 diff hist +5,845 Stepper 2 (AutoStep 200) Operating Procedures standard operating procedure Tag: Visual edit
- 10:15, 6 June 2019 diff hist +2,947 Stepper 1 (GCA 6300) - Standard Operating Procedure focus exposure matrix Tag: Visual edit
- 09:51, 6 June 2019 diff hist +119 Stepper 1 (GCA 6300) - Standard Operating Procedure →Running a JOB-Normal Operation Tag: Visual edit
- 09:14, 6 June 2019 diff hist +5,069 Stepper 1 (GCA 6300) - Standard Operating Procedure →Cleaning the back-side of wafer Tag: Visual edit
- 14:50, 31 May 2019 diff hist -572 Stepper 1 (GCA 6300) - Standard Operating Procedure wafer loading Tag: Visual edit
- 14:37, 31 May 2019 diff hist +941 Stepper 2 (AutoStep 200) Operating Procedures Setting up the job Tag: Visual edit
- 14:24, 31 May 2019 diff hist -2 Stepper 2 (AutoStep 200) Operating Procedures →Loading a wafer into the system Tag: Visual edit
- 14:23, 31 May 2019 diff hist +2,111 Stepper 2 (AutoStep 200) Operating Procedures loading the wafer Tag: Visual edit
- 13:42, 31 May 2019 diff hist -1,458 Stepper 2 (AutoStep 200) Operating Procedures →Reticle Loading and Unloading Tag: Visual edit
- 13:08, 31 May 2019 diff hist +1,995 Stepper 1 (GCA 6300) - Standard Operating Procedure wafer loading Tag: Visual edit
- 13:02, 31 May 2019 diff hist -86 Stepper 1 (GCA 6300) - Standard Operating Procedure →Reticle Loading and Unloading Tag: Visual edit
- 13:01, 31 May 2019 diff hist +28 Stepper 1 (GCA 6300) - Standard Operating Procedure →Reticle Loading and Unloading Tag: Visual edit
- 12:58, 31 May 2019 diff hist +3,877 Stepper 1 (GCA 6300) - Standard Operating Procedure gca 6300 cleaning, loading reticle Tag: Visual edit
- 10:58, 31 May 2019 diff hist +7 N Stepper 1 (GCA 6300) - Standard Operating Procedure work in progress icon
- 10:57, 31 May 2019 diff hist +131 Stepper 1 (GCA 6300) →Operating Procedures: link to new SOP in progress Tag: Visual edit
- 10:53, 31 May 2019 diff hist +7 Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences work in progress
- 10:53, 31 May 2019 diff hist +125 Stepper 2 (AutoStep 200) →Operating Procedures: link to SOP Tag: Visual edit
- 10:51, 31 May 2019 diff hist +2,893 Stepper 2 (AutoStep 200) Operating Procedures →Reticle Loading/Unloading: Work In Progress Tag: Visual edit: Switched
- 10:50, 31 May 2019 diff hist 0 N Stepper 2 (Autostep 200) - Piece vs. Wafer Programming Differences blank page Tag: Visual edit
- 10:49, 31 May 2019 diff hist +67 Stepper 2 (AutoStep 200) →Operating Procedures: link to Job Programming Tag: Visual edit
- 10:24, 31 May 2019 diff hist +956 Stepper 2 (AutoStep 200) Operating Procedures initial sections
- 14:40, 26 March 2019 diff hist +2 Surface Analysis (KLA/Tencor Surfscan) Tag: Visual edit
- 14:40, 26 March 2019 diff hist -22 Surface Analysis (KLA/Tencor Surfscan) Tag: Visual edit
- 14:39, 26 March 2019 diff hist -75 Surface Analysis (KLA/Tencor Surfscan) Tag: Visual edit
- 14:38, 26 March 2019 diff hist +276 Surface Analysis (KLA/Tencor Surfscan) standard recipes info Tag: Visual edit
- 14:19, 26 March 2019 diff hist +15 N File:UCSBTEST2 for small particles.png current
- 14:06, 26 March 2019 diff hist +26 N File:UCSBTEST.png current
- 13:40, 26 March 2019 diff hist +72 N File:UCSBTEST2 - gain4 for (0.160-1.60)um particles.png current
- 15:54, 25 March 2019 diff hist -105 Stepper 1 (GCA 6300) practicing editing page Tag: Visual edit
- 15:53, 25 March 2019 diff hist +74 Stepper 1 (GCA 6300) →Operating Procedures: stepper operating procedure Tag: Visual edit