User contributions
Jump to navigation
Jump to search
- 15:08, 12 January 2022 diff hist +441 Frequently Asked Questions →Forcing Calls to use Wifi (not Cellular): additional troubleshooting Tag: Visual edit
- 15:22, 11 January 2022 diff hist -42 Stepper 3 (ASML DUV) →Operating Procedures: merged Troubleshooting into Operating Procedures Tag: Visual edit
- 10:43, 11 January 2022 diff hist +675 ASML Stepper 3 Error Recovery, Troubleshooting and Calibration →IQC (Image Quality Control) Calibration Check: method for adding focus correction to exposure Tag: Visual edit: Switched
- 08:48, 7 January 2022 diff hist +113 Video Training: Uploading to GauchoCast/Panopto (Internal) →Uploading to the Web current Tag: Visual edit: Switched
- 08:45, 7 January 2022 diff hist +13 Nanofab Staff Internal Pages →Video Training procedures Tag: Visual edit
- 08:43, 7 January 2022 diff hist +2,328 N Video Training - Introduction (Internal) general methods - Demis current Tag: Visual edit
- 08:24, 7 January 2022 diff hist +89 Nanofab Staff Internal Pages →NanoFab IT: mentoined where to find instrucitons on Google Drive Tag: Visual edit
- 22:33, 6 January 2022 diff hist +91 Nanofab Staff Internal Pages moved olf pages to bottom Tag: Visual edit
- 22:32, 6 January 2022 diff hist +183 Nanofab Staff Internal Pages added NanoFab IT, and linked to NanoFab-it OnDema filter/page Tag: Visual edit
- 23:08, 4 January 2022 diff hist +6 m Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): credit Demis for the data Tag: Visual edit
- 14:58, 4 January 2022 diff hist +159 UCSB NanoFab Microscope Training →Depth Measurements using focus: added meas. error Tag: Visual edit
- 12:54, 4 January 2022 diff hist +100 m Packaging Recipes →Blade Exposure Calculation Tag: Visual edit
- 12:52, 4 January 2022 diff hist -30 m Packaging Recipes →Blade Exposure Calculation: enlarge img Tag: Visual edit
- 12:51, 4 January 2022 diff hist +191 Packaging Recipes →Calculated Blade Exposures: added blade exposure calc Tag: Visual edit
- 12:50, 4 January 2022 diff hist +37 N File:ADT Dicing - Blade Exposure diagram.png current
- 12:41, 4 January 2022 diff hist +1,753 Packaging Recipes →Dicing Saw Recipes (ADT 7100): added Dicing Tips Tag: Visual edit
- 11:29, 4 January 2022 diff hist +35 Tool List →Inspection, Test and Characterization: rearranged, moved "other properties" to end, renamed "Surfscan" to "particle counts" Tag: Visual edit
- 11:13, 4 January 2022 diff hist +79 Test Data of etching SiO2 with CHF3/CF4 →Alternate Data (not updated since 2019) Tag: Visual edit
- 11:12, 4 January 2022 diff hist +209 Test Data of etching SiO2 with CHF3/CF4 pasted link to alternate etch data Tag: Visual edit
- 11:11, 4 January 2022 diff hist -158 ICP Etching Recipes →Historical Data (SiO2 Etch, Panasonic 2): removed 2nd data table Tag: Visual edit
- 13:36, 3 January 2022 diff hist -693 Template:Announcements Deleted Flu vacc. mandate
- 13:34, 3 January 2022 diff hist +4 Template:Announcements →Jan 2022 UCSB COVID Protocols
- 13:33, 3 January 2022 diff hist +1,993 Template:Announcements pasted useful UCSB Jan COVID policiues
- 16:10, 21 December 2021 diff hist 0 File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png John d uploaded a new version of File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png current
- 16:09, 21 December 2021 diff hist +36 MLA150 - Troubleshooting →Out Of Focus Exposures: "features less than 100µm" Tag: Visual edit
- 11:52, 21 December 2021 diff hist -5 m MLA150 - Troubleshooting →Out Of Focus Exposures Tag: Visual edit
- 11:52, 21 December 2021 diff hist +285 MLA150 - Troubleshooting →Out Of Focus Exposures: inserted image of out-of-focus exposure Tag: Visual edit
- 11:50, 21 December 2021 diff hist +87 N File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png
- 11:39, 21 December 2021 diff hist -3 m MLA150 - Troubleshooting fix bullets
- 11:38, 21 December 2021 diff hist -2 m MLA150 - Troubleshooting →Unexpected Behavior Tag: Visual edit
- 11:34, 21 December 2021 diff hist -38 MLA150 - Troubleshooting rearranged sections, increased heading level to 1 & 2 Tag: Visual edit
- 11:07, 21 December 2021 diff hist +62 MLA150 - Troubleshooting Tag: Visual edit
- 00:26, 16 December 2021 diff hist +182 Nanofab Staff Internal Pages →Old / Defunct Tag: Visual edit
- 00:21, 16 December 2021 diff hist +94 m Ion Beam Deposition (Veeco NEXUS) →Recipes Tag: Visual edit
- 00:19, 16 December 2021 diff hist -424 Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): deleted IBD Cals spreadsheet Tag: Visual edit
- 00:18, 16 December 2021 diff hist +426 Old Deposition Data - 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): added IBD Cals spreadsheet current Tag: Visual edit
- 00:15, 16 December 2021 diff hist -2 Old Deposition Data - 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): promoted to Page Title
- 00:15, 16 December 2021 diff hist +359 Old Deposition Data - 2021-12-15 →SiO2 deposition (IBD): added old IBD data Tag: Visual edit
- 00:12, 16 December 2021 diff hist +6,481 Old Deposition Data - 2021-12-15 pasted Old (2021-12-15) IBD recipe data
- 00:11, 16 December 2021 diff hist -613 Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): pasted Nastazia M's new data
- 00:09, 16 December 2021 diff hist -12,460 PECVD Recipes pasted NastaziaM's new data links
- 00:07, 16 December 2021 diff hist +167 Deposition Data - temporary 2021-12-15 →Standard Cleaning Procedure (IBD): cleaning current Tag: Visual edit
- 00:05, 16 December 2021 diff hist +575 Deposition Data - temporary 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): pasted SiOxNy data
- 00:03, 16 December 2021 diff hist +2,234 Deposition Data - temporary 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): updated IBD Tag: Visual edit
- 23:49, 15 December 2021 diff hist +1,751 Deposition Data - temporary 2021-12-15 New data links Tag: Visual edit
- 07:35, 15 December 2021 diff hist +24,157 N Old Deposition Data - 2021-12-15 Created page with "OLD Data: Copied on 2021-12-14 {{recipes|Vacuum Deposition}} =PECVD 1 (PlasmaTherm 790)= ====Historical Particulate Data==== *[https://docs.google.com/spreadsheets/d..." Tag: Visual edit: Switched
- 07:35, 15 December 2021 diff hist +107 Nanofab Staff Internal Pages →Old / Defunct Tag: Visual edit
- 07:32, 15 December 2021 diff hist -11,328 Deposition Data - temporary 2021-12-15
- 07:31, 15 December 2021 diff hist +26 Deposition Data - temporary 2021-12-15 Tag: Visual edit
- 07:31, 15 December 2021 diff hist +24,158 N Deposition Data - temporary 2021-12-15 pasted old data