User contributions
Jump to navigation
Jump to search
- 13:33, 3 September 2021 diff hist -4 m DSEIII (PlasmaTherm/Deep Silicon Etcher) corrected header level Tag: Visual edit
- 13:14, 3 September 2021 diff hist +359 Laser Etch Monitoring →Specific Procedures: Added Oxford Laser Mon Tag: Visual edit
- 13:13, 3 September 2021 diff hist +40 Tool List →ICP-RIE: link to Oxford ICP new page Tag: Visual edit
- 12:55, 3 September 2021 diff hist 0 File:Annotated PR etch - Om1000 03 - ARC + Cl + PR etch v1.jpg John d uploaded a new version of File:Annotated PR etch - Om1000 03 - ARC + Cl + PR etch v1.jpg current
- 09:35, 30 August 2021 diff hist -729 Template:Announcements deleted aidan's announcements
- 14:47, 27 August 2021 diff hist +299 Microscopes added Filmetrics F40-UV Tag: Visual edit
- 14:43, 27 August 2021 diff hist +139 Microscopes →Procedures & Tools: General-Use vs. Training-Required sections Tag: Visual edit
- 10:25, 26 August 2021 diff hist +1 m Services →Other U.C. Campuses: indent Attachment A
- 10:25, 26 August 2021 diff hist 0 m Services →Other U.C. Campuses: indent Attachment A
- 10:24, 26 August 2021 diff hist -8 m Services →Other U.C> Campuses: removed redlink to questionnaire, →Fabrication Services by NanoFab Staff: minor wording/formatting Tag: Visual edit
- 08:34, 26 August 2021 diff hist +135 Process Group - Remote Fabrication Jobs direct link to Fab Svc wall Tag: Visual edit
- 08:21, 26 August 2021 diff hist +143 Services →Fabrication Services by NanoFab Staff: formatting updates Tag: Visual edit: Switched
- 14:47, 24 August 2021 diff hist +30 PECVD 2 (Advanced Vacuum) moved recipes to bottom (like other pages) Tag: Visual edit
- 14:46, 24 August 2021 diff hist +8 PECVD 1 (PlasmaTherm 790) →Recipes & Process Data: renamed to Recipes and Historical Tag: Visual edit
- 14:45, 24 August 2021 diff hist +40 PECVD 2 (Advanced Vacuum) →Recipes: renamed to Recipes & Historical Tag: Visual edit
- 15:05, 23 August 2021 diff hist +81 Template:Announcements slashes on users
- 15:03, 23 August 2021 diff hist +6 m Template:Announcements changed CDA to Aidan
- 15:03, 23 August 2021 diff hist +365 Template:Announcements CDA repair closures
- 09:20, 7 August 2021 diff hist +157 Contact Aligner (SUSS MA-6) link to recipes Tag: Visual edit
- 14:18, 4 August 2021 diff hist +362 Autostep 200 Mask Making Guidance →Photomask Ordering Info: updated Photomask pordering info, added GDS template file Tag: Visual edit
- 14:15, 4 August 2021 diff hist +194 N File:GCA Stepper MaskPlate Master-DarkField 5x.gds GCA Stepper (Autostep 200 or 6300) Photomask template. Darkfield, at Reticle-scale (5x magnification already applied). Insert your design as Instances with 5x up-scaling applied. current
- 12:16, 3 August 2021 diff hist +263 MLA150 - Troubleshooting →Known Bugs & Workarounds: Stage bot centered - note about Small / OV camera Tag: Visual edit
- 09:50, 3 August 2021 diff hist +38 Test Data of etching SiO2 with CHF3/CF4 Comment on 7/22 check. Tag: Visual edit
- 12:05, 2 August 2021 diff hist +77 Template:Announcements SEM2 update from Aidan
- 12:04, 2 August 2021 diff hist -1 m Template:Announcements corrected timestamp
- 12:03, 2 August 2021 diff hist +39 Template:Announcements corrected timestamp
- 10:31, 30 July 2021 diff hist +113 Template:Announcements Sem 2 down
- 10:58, 27 July 2021 diff hist -10 m Stepper Recipes →DUV-42P-6: updated spin speed / noted mistake Tag: Visual edit
- 10:19, 27 July 2021 diff hist +991 Process Group - Remote Fabrication Jobs Links ot OnDema pages for each employee Tag: Visual edit
- 10:15, 27 July 2021 diff hist -13 Nanofab Staff Internal Pages →Process Group: minor rename Tag: Visual edit
- 11:58, 20 July 2021 diff hist +169 MLA150 - Troubleshooting →Defocus: unable to enter ±25 full range: Added name of recent Resist tempalte "General-Focus" Tag: Visual edit
- 10:50, 15 July 2021 diff hist +583 MLA150 - Design Guidelines →Alignment Marks: comment on mark placement across wafer Tag: Visual edit
- 10:42, 15 July 2021 diff hist +145 MLA150 - Design Guidelines →Automatic Alignment: added Reduced Detection area Tag: Visual edit
- 10:03, 15 July 2021 diff hist +663 MLA150 - Design Guidelines added alignment marks Tag: Visual edit
- 10:53, 14 July 2021 diff hist +65 ICP Etching Recipes →PlasmaTherm/SLR Fluorine Etcher: section header for Cleaning Recipes / TBA Tag: Visual edit
- 10:01, 14 July 2021 diff hist -47 Wet Etching Recipes →The Master Table of Wet Etching (Include All Materials): deleted 2nd "Extra Notes" column, combined date into "Verified by" Tag: Visual edit
- 08:19, 14 July 2021 diff hist +69 Wet Etching Recipes →The Master Table of Wet Etching (Include All Materials): KOH > linked to KOH bath Tag: Visual edit
- 10:46, 13 July 2021 diff hist +41 N File:200um square v1.gds TESTING only - please delte current
- 13:47, 12 July 2021 diff hist +48 m Stepper Recipes →DUV-42P-6: updated etching links Tag: Visual edit
- 13:43, 12 July 2021 diff hist +16 m ICP Etching Recipes →Photoresist and ARC Etching (Panasonic 1): fixed URL link Tag: Visual edit
- 14:19, 9 July 2021 diff hist +928 Atomic Layer Deposition Recipes →Atomic Layer Deposition (Oxford FlexAL): Recipe info on Plasma, Ratios Tag: Visual edit
- 11:49, 9 July 2021 diff hist -2 Services →Other U.C. Campuses: corrected broken email link
- 16:50, 8 July 2021 diff hist +40 Autostep 200 Mask Making Guidance added magnification Tag: Visual edit
- 16:48, 8 July 2021 diff hist +5 Autostep 200 Mask Making Guidance corercted dimensions to 5x5x0.090 Tag: Visual edit
- 16:44, 8 July 2021 diff hist +163 Autostep 200 Mask Making Guidance added Plate materials/dimensions Tag: Visual edit
- 11:20, 7 July 2021 diff hist +88 Nanofab Staff Internal Pages →Process Group: added link to Supplies Costs Tag: Visual edit
- 12:55, 2 July 2021 diff hist +91 Process Group - Billing Instructions →Supplies Costs: sotrage location in notes Tag: Visual edit
- 12:53, 2 July 2021 diff hist -2 m Process Group - Billing Instructions →Supplies Charges: --> Supplies Costs Tag: Visual edit
- 12:53, 2 July 2021 diff hist +51 Process Group - Billing Instructions force TOC
- 12:45, 2 July 2021 diff hist +16 Process Group - Billing Instructions →Supplies Charges: updated prices wafers Tag: Visual edit