Difference between revisions of "Lithography Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(→‎Photolithography Recipes: added MLA150 to PhotoLith recipes table; table color formatting)
m (fixed link)
 
(57 intermediate revisions by 4 users not shown)
Line 1: Line 1:
  +
__NOTOC__
==General Information==
 
 
This page contains information and links to recipes/datasheets spin-coated materials used in the facility.
 
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
Line 8: Line 5:
 
|-
 
|-
 
|
 
|
  +
==='''<big>Photolithography Processes</big>'''===
*'''[[#PositivePR |Photoresists]]'''
 
**[[#Photolithography_Recipes |Photo Lithography Recipe section]]
 
***''Has links to starting recipes (spin, bake, exposure, develop etc.).''
 
***''Substrate, surface materials, pattern size can often affect process parameters. Users may need to run Focus/Exposure Arrays/Matrix (FEA's/FEM's) with these processes to achieve high-resolution.''
 
**[[#PositivePR |Stocked Lithography Chemical + Datasheets]]
 
***''Lists all stocked photolith. chemicals, PRs, strippers, developers, and links to the chemical's application notes/datasheet, which detail the spin curves and nominal processes.''
 
*'''[[#EBLPR |E-beam Lithography Resists]]'''
 
**[[#E-Beam_Lithography_Recipes |E-Beam Lithography Recipes]]
 
***''Has links to starting recipes. Substrates and patterns play a large role in process parameters.''
 
**[[#EBLPR |EBL Photoresist Datasheets]]
 
***''Provided for reference, also showing starting recipes and usage info.''
 
*'''[[#NanoImprinting |Nanoimprinting Resists]]'''
 
**''Datasheets are provided with starting recipes and usage info.''
 
**''Recipes provided are for use in the [[Nano-Imprint_(Nanonex_NX2000) |Nano-Imprint (Nanonex NX2000)]] system only.''
 
   
  +
#'''UV Optical Lithography'''
*'''[[#Underlayers |Underlayers]]'''
 
  +
#*[[#PositivePR |'''Stocked Lithography Chemical + Datasheets''']]
**''These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.''
 
  +
#**''Lists all stocked photolith. chemicals, PRs, strippers, developers, and links to the chemical's application notes/datasheet, which detail the spin curves and nominal processes.''
**''Datasheets are provided.''
 
*[[#Lift-Off_Techniques |'''Lift-Off Techniques''']]
+
#*[[#Photolithography_Recipes |'''Photo Lithography Recipe section''']]
**''Verified Recipes for lift-off using various photolith. tools''
+
#**''Starting recipes (spin, bake, exposure, develop etc.) for all photolith. tools.''
  +
#**''Substrate/surface materials/pattern size can affect process parameters. Users may need to run Focus/Exposure Arrays/Matrix (FEA's/FEM's) with these processes to achieve high-resolution.''
**''General educational description of this technique and it's limitations/considerations.''
 
  +
#**[[Contact Alignment Recipes|<u>Contact Aligner Recipes</u>]]
*'''[[Lithography Recipes#Holography Recipes|Holography]]'''
 
  +
#***[[Contact Alignment Recipes#Suss Aligners .28SUSS MJB-3.29|Suss MJB Aligners]]
**''For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square.''
 
  +
#***[[Contact Alignment Recipes#Contact Aligner .28SUSS MA-6.29|Suss MA6]]
**''Recipes for silicon substrates are provided, and have been translated to other substrates by users.''
 
  +
#**[[Stepper Recipes|<u>Stepper Recipes</u>]]
*'''[[#AntiReflectionCoatings |Anti-Reflection Coatings]]''':
 
  +
#***[[Stepper Recipes#Stepper 1 .28GCA 6300.29|Stepper #1: GCA 6300]] (I-Line)
**[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials.
 
  +
#***[[Stepper Recipes#Stepper 2 .28AutoStep 200.29|Stepper #2: GCA Autostep 200]] (I-Line)
**''Bottom Anti-Reflection Coatings (BARC) are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes.''
 
  +
#***[[Stepper Recipes#Stepper 3 .28ASML DUV.29|Stepper #3: ASML PAS 5500/300]] (DUV)
**''Datasheets are provided for reference on use of the materials.''
 
  +
#**[[Direct-Write Lithography Recipes|<u>Direct-Write Recipes</u>]]
*'''[[#ContrastEnhancement |Contrast Enhancement Materials (CEM)]]'''
 
  +
#***[[Direct-Write Lithography Recipes#Maskless Aligner .28Heidelberg MLA150.29|Heidelberg MLA150]]
**[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials.
 
  +
#***[[Lithography Recipes#E-Beam Lithography Recipes|JEOL JBX-6300FS EBL]]
**''Used for resolution enhancement. Not for use in contact aligners, typically used on I-Line Steppers.''
 
  +
#***[[Lithography Recipes#FIB Lithography Recipes .28Raith Velion.29|Raith Velion FIB]]
**''Datasheets provided with usage info.''
 
  +
#**[[Lithography Recipes#Automated Coat.2FDevelop System Recipes .28S-Cubed Flexi.29|Automated Coater Recipes (S-Cubed Flexi)]]
*'''[[#AdhesionPromoters |Adhesion Promoters]]'''
 
  +
#[[Lithography Recipes#General Photolithography Techniques|'''General Photolithography Techniques''']]
**''These are used to improve wetting of photoresists to your substrate.''
 
  +
#*''Techniques for improving litho. or solving common photolith. problems.''
**''Datasheets are provided on use of these materials.''
 
  +
#'''[[Lithography Recipes#Lift-Off Recipes|Lift-Off Recipes]]'''
  +
#*''Verified Recipes for lift-off using various photolith. tools''
  +
#*''General educational description of this technique and it's limitations/considerations.''
  +
#'''E-beam Lithography'''
  +
#*[[#E-Beam_Lithography_Recipes |E-Beam Lithography Recipes]]
  +
#**''Has links to starting recipes. Substrates and patterns play a large role in process parameters.''
  +
#*[[#EBLPR |EBL Photoresist Datasheets]]
  +
#**''Provided for reference, also showing starting recipes and usage info.''
  +
#'''[[Lithography Recipes#Holography Recipes|Holography]]'''
  +
#*''For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square.''
  +
#*''Recipes for silicon substrates are provided, and have been translated to other substrates by users.''
  +
#*''Datasheets are provided with starting recipes and usage info.''
  +
#'''[[Lithography Recipes#Edge-Bead Removal Techniques|Edge-Bead Removal]]'''
  +
#*''Edge photoresist removal methods needed for clamp-based etchers''
  +
#*''Improves resolution for contact lithography''
  +
|-
  +
|
  +
  +
==='''<big>Photolithography Chemicals/Materials</big>'''===
   
*'''[[#SpinOnDielectrics |Low-K Spin-on Dielectrics]]'''
+
#'''[[#Underlayers |Underlayers]]'''
  +
#*''These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.''
**[[Lithography Recipes#SpinOnDielectrics|Spin-On Dielectrics]]
 
***''Datasheets for BCB, Photo-BCB, and SOG (spin-on-glass) for reference on use.''
+
#*''Datasheets are provided.''
  +
#'''[[#AntiReflectionCoatings |Anti-Reflection Coatings]]''':
**[[#Low-K_Spin-On_Dielectric_Recipes |Low-K Spin-On Dielectric Recipes]]
 
  +
#*[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials.
***''Recipes for usage of some spin-on dielectrics.''
 
  +
#*''Bottom Anti-Reflection Coatings (BARC) are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes.''
*'''[[#Developers |Developers and Removers]]'''
 
**''Datasheets provided for reference.''
+
#*''Datasheets are provided for reference on use of the materials.''
  +
#'''[[#ContrastEnhancement |Contrast Enhancement Materials (CEM)]]'''
**''Remover and Photoresist Strippers are used to dissolve PR during lift-off or after etching.''
 
  +
#*[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials.
  +
#*''Used for resolution enhancement. Not for use in contact aligners, typically used on I-Line Steppers.''
  +
#*''Datasheets provided with usage info.''
  +
#'''[[#AdhesionPromoters |Adhesion Promoters]]'''
  +
#*''These are used to improve wetting of photoresists to your substrate.''
  +
#*''Datasheets are provided on use of these materials.''
  +
#'''[[#SpinOnDielectrics |Low-K Spin-on Dielectrics]]'''
  +
#*[[Lithography Recipes#SpinOnDielectrics|Spin-On Dielectrics]]
  +
#**''Datasheets for BCB, Photo-BCB, and SOG (spin-on-glass) for reference on use.''
  +
#*[[#Low-K_Spin-On_Dielectric_Recipes |Low-K Spin-On Dielectric Recipes]]
  +
#**''Recipes for usage of some spin-on dielectrics.''
  +
#'''[[#Developers |Developers and Removers]]'''
  +
#*''Datasheets provided for reference.''
  +
#*''Remover and Photoresist Strippers are used to dissolve PR during lift-off or after etching.''
 
|}
 
|}
  +
  +
==General Photolithography Techniques==
  +
  +
====[[Photolithography - Improving Adhesion Photoresist Adhesion|'''HMDS Process for Improving Adhesion''']]====
  +
  +
*''Use these procedures if you are finding poor adhesion PR lifting-off), or for chemicals (like BHF) that attack the PR adhesion interface strongly.''
  +
  +
====[[Photolithography - Manual Edge-Bead Removal Techniques|'''Edge-Bead Removal Techniques''']]====
  +
  +
*''These techniques are required for loading full-wafers into etchers that use top-side clamps, to prevent photoresist from sticking to the clamp (and potentially destroying your wafer).''
  +
*''For contact lithography, this improves the proximity of the mask plate and sample, improving resolution. For some projection systems, such as the [[Maskless Aligner (Heidelberg MLA150)|Maskless Aligner]], EBR can help with autofocus issues.''
  +
  +
====[https://www.microchemicals.com/technical_information/reflow_photoresist.pdf '''Photoresist reflow (MicroChem)''']====
  +
  +
*''To create slanted sidewalls or curved surfaces.''
   
 
==Photolithography Recipes==
 
==Photolithography Recipes==
   
  +
*<small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small>
{{Recipe Table Explanation}}
 
  +
*<small>'''A''': ''Material is available for use, but no recipes are provided.''</small>
   
  +
''Click the tool title to go to recipes for that tool.''
  +
  +
''Click the photoresist title to get the datasheet, also found in [[Lithography Recipes#Chemicals Stocked .2B Datasheets|Stocked Chemicals + Datasheets]].''
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1"
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1"
  +
|-
|- bgcolor="#D0E7FF"
 
! colspan="10" height="45" |<div style="font-size: 150%;">Photolithography Recipes</div>
+
! colspan="7" height="45" |<div style="font-size: 150%;">Photolithography Recipes</div>
   
  +
|-
|- bgcolor="#D0E7FF"
 
|<!-- INTENTIONALLY BLANK --><br>
+
| bgcolor="#EAECF0" |<!-- INTENTIONALLY BLANK -->
! colspan="2" bgcolor="#D0E7FF" align="center" |'''[[Contact Alignment Recipes|<big>Contact Aligner Recipes</big>]]'''
+
! colspan="2" align="center" |'''[[Contact Alignment Recipes|<big>Contact Aligner Recipes</big>]]'''
! colspan="3" bgcolor="#D0E7FF" align="center" |'''[[Stepper Recipes|<big>Stepper Recipes</big>]]'''
+
! colspan="3" align="center" |'''[[Stepper Recipes|<big>Stepper Recipes</big>]]'''
  +
! align="center" |[[Direct-Write Lithography Recipes|Direct-Write Litho. Recipes]]
! colspan="3" bgcolor="#D0E7FF" align="center" |Other
 
 
|-
 
|-
 
! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists'''
 
! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists'''
 
{{LithRecipe Table}}
 
{{LithRecipe Table}}
  +
|- bgcolor="EEFFFF"<!-- This is the Row color: lightblue -->
! width="150" bgcolor="#D0E7FF" align="center" |'''[[MLA150 Recipes|<big>MLA150</big>]]'''
 
  +
| bgcolor="#D0E7FF" align="center" |[[:File:AXP4000pb-Datasheet.pdf|AZ4110]]
|-
 
  +
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
| bgcolor="#D0E7FF" align="center" |AZ4110
 
| bgcolor="EEFFFF" |{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
+
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
  +
|A
| bgcolor="EEFFFF" |{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
  +
|A
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |
 
 
|
 
|
  +
|{{rl|MLA_Recipes|Positive Resist (MLA 150)}}
|-
 
  +
|-<!-- This is a White row color -->
| bgcolor="#D0E7FF" align="center" |AZ4210
 
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/f/fc/AXP4000pb-Datasheet.pdf AZ4210]
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
|A
 
|A
 
|A
 
|A
|<br>
 
 
|
 
|
|-
+
|A
| bgcolor="#D0E7FF" align="center" |AZ4330RS
+
|- bgcolor="EEFFFF"
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/f/fc/AXP4000pb-Datasheet.pdf AZ4330RS]
| bgcolor="EEFFFF" |{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
| bgcolor="EEFFFF" |{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
+
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
  +
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
| bgcolor="EEFFFF" |A
 
  +
|A
| bgcolor="EEFFFF" |A
 
  +
|A
| bgcolor="EEFFFF" |
 
 
|
 
|
  +
|{{rl|MLA_Recipes|Positive Resist (MLA 150)}}
 
|-
 
|-
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/a/a2/Az_p4620_photoresist_data_package.pdf AZ4620]
|AZ4620
 
|
+
|A
|
+
|A
|
+
|A
|
+
|A
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="EEFFFF"
|-
 
| bgcolor="#D0E7FF" align="center" |OCG 825-35CS
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/8/8b/OCG825-Positive-Resist-Datasheet.pdf OCG 825-35CS]
 
|A
 
|A
 
|A
 
|A
 
|A
 
|A
 
|A
 
|A
|<br>
 
 
|
 
|
|-
+
|A
| bgcolor="#D0E7FF" align="center" |SPR 950-0.8
+
|- bgcolor="EEFFFF"
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/2/29/SPR955-Positive-Resist-Datasheet.pdf SPR 955 CM-0.9]
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |
 
|
 
|-
 
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-0.9
 
 
|A
 
|A
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
|{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
 
|{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
|<br>
 
 
|
 
|
  +
|{{rl|MLA Recipes|Positive Resist (MLA 150)}}
 
|-
 
|-
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-1.8
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/2/29/SPR955-Positive-Resist-Datasheet.pdf SPR 955 CM-1.8]
  +
|A
| bgcolor="EEFFFF" |A
 
  +
|A
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
+
|{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
+
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
| bgcolor="EEFFFF" |
 
 
|
 
|
|-
+
|A
| bgcolor="#D0E7FF" align="center" |SPR 220-3.0
+
|- bgcolor="EEFFFF"
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/3/3f/SPR220-Positive-Resist-Datasheet.pdf SPR 220-3.0]
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
|{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
 
|{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
|<br>
 
 
|
 
|
  +
|{{rl|MLA Recipes|Positive Resist (MLA 150)}}
 
|-
 
|-
| bgcolor="#D0E7FF" align="center" |SPR 220-7.0
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/3/3f/SPR220-Positive-Resist-Datasheet.pdf SPR 220-7.0]
| bgcolor="EEFFFF" |{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
+
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
| bgcolor="EEFFFF" |{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
+
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
+
|{{rl|Stepper Recipes|Positive Resist (GCA 6300)}}
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
+
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
| bgcolor="EEFFFF" |
 
 
|
 
|
|-
 
| bgcolor="#D0E7FF" align="center" |THMR-IP3600 HP D
 
|<br>
 
|<br>
 
 
|A
 
|A
  +
|- bgcolor="EEFFFF"
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/b/be/3600_D%2C_D2v_Spin_Speed_Curve.pdf THMR-IP3600 HP D]
  +
|
  +
|
 
|A
 
|A
|<br>
 
 
|A
 
|A
|-
 
| bgcolor="#D0E7FF" align="center" |UV6-0.8
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (ASML DUV)}}
 
 
|
 
|
  +
|{{rl|MLA Recipes|Positive Resist (MLA 150)}}
 
|-
 
|-
| bgcolor="#D0E7FF" align="center" |UV210-0.3
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/3/38/UV6-Positive-Resist-Datasheet.pdf UV6-0.8]
 
|
 
|
 
|
 
|
Line 175: Line 194:
 
|{{rl|Stepper Recipes|Positive Resist (ASML DUV)}}
 
|{{rl|Stepper Recipes|Positive Resist (ASML DUV)}}
 
|
 
|
  +
|- bgcolor="EEFFFF"
|-
 
| bgcolor="#D0E7FF" align="center" |UV26-2.5
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/f/ff/UV210-Positive-Resist-Datasheet.pdf UV210-0.3]
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|{{rl|Stepper Recipes|Positive Resist (ASML DUV)}}
| bgcolor="EEFFFF" |A
 
 
|
 
|
 
|-
 
|-
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/0/07/UV26-Positive-Resist-Datasheet.pdf UV26-2.5]
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|
  +
|- bgcolor="EEFFFF"
 
! bgcolor="#D0E7FF" align="center" |'''Negative Resists'''
 
! bgcolor="#D0E7FF" align="center" |'''Negative Resists'''
 
{{LithRecipe Table}}
 
{{LithRecipe Table}}
  +
|-
|MLA150
 
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/b/b0/AZ5214-Negative-Resist-Datasheet.pdf AZ5214-EIR]
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |AZ5214-EIR
 
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
Line 194: Line 220:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
  +
|{{rl|MLA Recipes|Negative Resist (MLA 150)}}
|
 
  +
|- bgcolor="EEFFFF"
|-
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2020
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/5/5e/AZnLOF2020-Negative-Resist-Datasheet.pdf AZnLOF 2020]
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
Line 202: Line 228:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
  +
|{{rl|MLA Recipes|Negative Resist (MLA 150)}}
|
 
  +
|-
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/5/5e/AZnLOF2020-Negative-Resist-Datasheet.pdf AZnLOF 2035]
  +
| bgcolor="EEFFFF" |A
  +
| bgcolor="EEFFFF" |A
  +
| bgcolor="EEFFFF" |A
  +
| bgcolor="EEFFFF" |A
  +
| bgcolor="EEFFFF" |
  +
| bgcolor="EEFFFF" |A
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |AZnLOF 2035
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/5/5e/AZnLOF2020-Negative-Resist-Datasheet.pdf AZnLOF 2070]
 
|A
 
|A
 
|A
 
|A
Line 210: Line 244:
 
|A
 
|A
 
|
 
|
|
 
|-
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2070
 
 
|A
 
|A
|A
+
|-
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/8/82/AZnLOF5510-Negative-Resist-Datasheet.pdf AZnLOF 5510]
|A
 
|A
 
|
 
|
 
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 5510
 
 
|A
 
|A
 
|A
 
|A
Line 226: Line 252:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
|
+
|A
  +
|- bgcolor="EEFFFF"
|-
 
| bgcolor="#D0E7FF" align="center" |UVN30-0.8
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/c/c9/UVN-30_-_Negative-Resist-Datasheet_-_Apr_2004.pdf UVN30-0.8]
 
|
 
|
 
|
 
|
Line 235: Line 261:
 
|{{rl|Stepper Recipes|Negative Resist (ASML DUV)}}
 
|{{rl|Stepper Recipes|Negative Resist (ASML DUV)}}
 
|
 
|
  +
|-
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |SU-8 2005,2010, 2015
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/7/78/SU-8-2015-revA.pdf SU-8 2005,2010,2015]
 
|A
 
|A
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
 
|{{rl|Contact_Alignment_Recipes|Negative Resist (MA-6)}}
Line 242: Line 268:
 
|A
 
|A
 
|
 
|
|
+
|A
  +
|- bgcolor="EEFFFF"
|-
 
| bgcolor="#D0E7FF" align="center" |SU-8 2075
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/2/2c/SU-8-2075-revA.pdf SU-8 2075]
 
|A
 
|A
 
|A
 
|A
Line 250: Line 276:
 
|A
 
|A
 
|
 
|
  +
|{{rl|MLA Recipes|Negative Resist (MLA 150)}}
|
 
  +
|-
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |NR9-1000,3000,6000PY
+
| bgcolor="#D0E7FF" align="center" |NR9-[//wiki.nanotech.ucsb.edu/w/images/8/8f/NR9-1000PY-revA.pdf 1000],[//wiki.nanotech.ucsb.edu/w/images/7/71/NR9-3000PY-revA.pdf 3000],[//wiki.nanotech.ucsb.edu/w/images/f/f9/NR9-6000PY-revA.pdf 6000]PY
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
 
|{{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}
Line 258: Line 284:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
|
+
|A
  +
|- bgcolor="EEFFFF"
|-
 
! bgcolor="#D0E7FF" align="center" | '''Anti-Reflection Coatings'''
+
! bgcolor="#D0E7FF" align="center" |'''Anti-Reflection Coatings'''
 
{{LithRecipe Table}}
 
{{LithRecipe Table}}
  +
|-
|MLA150
 
  +
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/3/33/XHRiC-Anti-Reflective-Coating.pdf XHRiC-11]
  +
|
  +
|
  +
|A
  +
|A
  +
|
  +
|A
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" |DUV42-P
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/0/07/DUV42P-Anti-Reflective-Coating.pdf DUV42-P]
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
|{{rl|Stepper Recipes|DUV-42P}}
+
|{{rl|Stepper Recipes|DUV-42P-6}}
  +
|
 
|
 
|
 
|-
 
|-
| bgcolor="#D0E7FF" align="center" |DS-K101-304
+
| bgcolor="#D0E7FF" align="center" |[//wiki.nanotech.ucsb.edu/w/images/a/af/DS-K101-304-Anti-Reflective-Coating.pdf DS-K101-304]
 
|
 
|
 
|
 
|
Line 282: Line 316:
 
! bgcolor="#D0E7FF" align="center" |
 
! bgcolor="#D0E7FF" align="center" |
 
{{LithRecipe Table}}
 
{{LithRecipe Table}}
|MLA150
 
 
|}
 
|}
 
<!-- end Litho Recipes table -->
 
<!-- end Litho Recipes table -->
  +
  +
==Lift-Off Recipes==
  +
  +
*{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}}
  +
**How it works, process limits and considerations for designing your process
  +
*[[Lift-Off with I-Line Imaging Resist + LOL2000 Underlayer|I-Line Lift-Off: Bi-Layer Process with LOL2000 Underlayer]]
  +
**''Single Expose/Develop process for simplicity''
  +
**''Up to ~130nm metal thickness & ≥500nm-1000nm gap between metal.''
  +
**''Can use any I-Line litho tool (GCA Stepper, Contact aligner, MLA)''
  +
*{{fl|Bi-LayerContactprocesswithPMGI.pdf|I-Line Lift-Off: Bi-Layer Process with PMGI Underlayer and Contact Aligner}}
  +
**''Multiple processes for Metal thicknesses ~800nm to ~2.5µm''
  +
**''Uses multiple DUV Flood exposure/develop cycles to create undercut.''
  +
**''Can be transferred to other I-Line litho tools (Stepper, MLA etc.)''
  +
*[[Lift-Off with DUV Imaging + PMGI Underlayer|DUV Lift-Off: UV6 Imaging Resist + PMGI Underlayer]]
  +
**''Single-expose/develop process''
  +
**''Up to ~65nm metal thickness & ~350nm gap between metal''
  +
**''Use thicker PMGI for thicker metals''
   
 
==[[E-Beam Lithography System (JEOL JBX-6300FS)|E-Beam Lithography Recipes (JEOL JBX-6300FS)]]==
 
==[[E-Beam Lithography System (JEOL JBX-6300FS)|E-Beam Lithography Recipes (JEOL JBX-6300FS)]]==
Line 290: Line 340:
 
*Under Development.
 
*Under Development.
   
== [[Focused Ion-Beam Lithography (Raith Velion)|FIB Lithography Recipes (Raith Velion)]] ==
+
==[[Focused Ion-Beam Lithography (Raith Velion)|FIB Lithography Recipes (Raith Velion)]]==
 
''To Be Added''
 
''To Be Added''
   
 
==[[Automated Coat/Develop System (S-Cubed Flexi)|Automated Coat/Develop System Recipes (S-Cubed Flexi)]]==
 
==[[Automated Coat/Develop System (S-Cubed Flexi)|Automated Coat/Develop System Recipes (S-Cubed Flexi)]]==
 
Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.
 
Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.
  +
{| class="wikitable"
  +
|+''Ask [[Tony Bosch|Staff]] if you need a new recipe.''
  +
|'''''<u>Coating Material</u>'''''
  +
|'''''<u>Route/Chain</u>'''''
  +
|'''''<u>Name</u>''': User: "UCSB Users"''
  +
|'''''<u>Spin Speed (krpm)</u>'''''
  +
|'''''<u>Bake Temp</u>'''''
  +
|'''''<u>Notes</u>'''''
  +
|-
  +
|'''''DS-K101'''''
  +
|''Route''
  +
| colspan="4" |''DSK101's Develop Rate depends on Bake temp - you can use this to control undercut.''
   
  +
''See: [[DS-K101-304 Bake Temp. versus Develop Rate|DSK Bake vs. Dev rate]]''
''To Be Added''
 
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-220C
  +
|5.0
  +
|220°C
  +
|''Requires: HP4=220°C''
  +
This is essentailly equivalent to [[Stepper Recipes#DUV-42P-6|DUV42P @ 220°C]], must be dry etched.
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-210C
  +
|5.0
  +
|210°C
  +
|''Requires: HP4=210°C''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-200C
  +
|5.0
  +
|200°C
  +
|''Requires: HP4=200°C''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-185C
  +
|5.0
  +
|185°C
  +
|''Requires: HP4=185°C''
  +
|-
  +
|'''''UV6-0.8'''''
  +
|''Route''
  +
|Coat-UV6[2K]-135C
  +
|2.0
  +
|135°C
  +
|''Requires: HP1=135°C''
  +
|-
  +
|
  +
|
  +
|Coat-UV6[2.5K]-135C
  +
|2.5
  +
|135°C
  +
|
  +
|-
  +
|
  +
|
  +
|Coat-UV6[3K]-135C
  +
|3.0
  +
|135°C
  +
|
  +
|-
  +
|
  +
|
  +
|Coat-UV6[3.5K]-135C
  +
|3.5
  +
|135°C
  +
|
  +
|-
  +
|
  +
|
  +
|Coat-UV6[4K]-135C
  +
|4.0
  +
|135°C
  +
|
  +
|-
  +
|
  +
|
  +
|Coat-UV6[5K]-135C
  +
|5.0
  +
|135°C
  +
|
  +
|-
  +
|
  +
|
  +
|Coat-UV6[6K]-135C
  +
|6.0
  +
|135°C
  +
|
  +
|-
  +
|'''''DS-K101 @ 220°C'''''
  +
'''''+ UV6'''''
  +
|''Chain''
  +
|Coat-DSK101[5K]-220C-UV6[2K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 2.0krpm''
  +
|DSK: 220°C
  +
UV6: 135°C
  +
|''Requires:''
  +
''– HP4=220°C''
   
  +
''– HP1=135°C''
==[[Nano-Imprint (Nanonex NX2000)|Nanoimprinting Recipes]]==
 
   
  +
''Plan for ~10-15 min per wafer.''
*{{fl|Thermal-Nanoimprint-Process-Tutorial-revA.pdf|Thermal Nanoimprint Process and Tutorial}}
 
  +
|-
*{{fl|Nanoinprint-Lithopgraphy-UV-Low-Pressure-Temperature-Ormostamp-PDMS-RevA.docx|UV-Cure Low Temp, Low Pressure, Soft-Stamp Nanoimprint Process}}
 
  +
|
  +
|
  +
|Coat-DSK101[5K]-220C-UV6[2.5K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 2.5krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-220C-UV6[3K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 3.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-220C-UV6[3.5K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 3.5krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-220C-UV6[4K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 4.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-220C-UV6[5K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 5.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-220C-UV6[6K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 6.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|'''''DS-K101 @ 185°C'''''
  +
'''''+ UV6'''''
  +
|''Chain''
  +
|Coat-DSK101[5K]-185C-UV6[2K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 2.0krpm''
  +
|DSK: 185°C
  +
UV6: 135°C
  +
|''Requires:''
  +
''– HP4=185°C''
   
  +
''– HP1=135°C''
  +
  +
''Plan for ~10-15 min per wafer.''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-185C-UV6[2.5K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 2.5krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-185C-UV6[3K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 3.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-185C-UV6[3.5K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 3.5krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-185C-UV6[4K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 4.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-185C-UV6[5K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 5.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|
  +
|
  +
|Coat-DSK101[5K]-185C-UV6[6K]-135C
  +
|''DSK: 5krpm''
  +
''UV6: 6.0krpm''
  +
|''same as above''
  +
|''same as above''
  +
|-
  +
|'''''Hotplate Set'''''
  +
|''Route''
  +
|''SET-HP4-220C''
  +
|
  +
|220°C
  +
|''Hotplate 4 (top) between 218-222°C when done.''
  +
|-
  +
|
  +
|
  +
|''SET-HP4-210C''
  +
|
  +
|210°C
  +
|
  +
|-
  +
|
  +
|
  +
|''SET-HP4-200C''
  +
|
  +
|200°C
  +
|
  +
|-
  +
|
  +
|
  +
|''SET-HP4-185C''
  +
|
  +
|185*C
  +
|
  +
|}
 
==[[Holographic Lith/PL Setup (Custom)|Holography Recipes]]==
 
==[[Holographic Lith/PL Setup (Custom)|Holography Recipes]]==
  +
''The Holography recipes here use the BARC layer XHRiC-11 & the high-res. I-Line photoresist THMR-IP3600HP-D.''
   
*{{fl|Holography_Process_for_1D-lines_and_2D-dots_(ARC-11_%26_THMR-IP3600HP-D)-updated-8-13-2018-A.pdf|Standard Holography Process - on SiO2 on Si}}
+
*{{fl|Holography_Process_for_1D-lines_and_2D-dots_%28ARC-11_%26_THMR-IP3600HP-D%29-updated-4-8-2021.pdf|Standard Holography Process - on SiO2 on Si}}
 
*{{fl|Holography-Process-Variation-revA.pdf|Holography Process Variations - Set-up Angle - Etching into SiO2 and Si}}
 
*{{fl|Holography-Process-Variation-revA.pdf|Holography Process Variations - Set-up Angle - Etching into SiO2 and Si}}
 
*{{fl|05-SiO2_Nano-structure_Etch.pdf|Etch SiO2 Nano-structure - Changing Side-wall Angle - Etching into Si with a different line-width}}
 
*{{fl|05-SiO2_Nano-structure_Etch.pdf|Etch SiO2 Nano-structure - Changing Side-wall Angle - Etching into Si with a different line-width}}
Line 315: Line 605:
 
*{{fl|BCB-cyclotene-3000-revA.pdf|Standard BCB (3022-46)}}
 
*{{fl|BCB-cyclotene-3000-revA.pdf|Standard BCB (3022-46)}}
 
*{{fl|512B-Application-Data-Bake-revA.pdf|SOG (T512B)}}
 
*{{fl|512B-Application-Data-Bake-revA.pdf|SOG (T512B)}}
 
==Lift-Off Techniques==
 
 
*{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}}
 
**How it works, process limits and considerations for designing your process
 
*{{fl|Bi-LayerContactprocesswithPMGI.pdf|I-Line Lift-Off: Bi-Layer Process with PMGI Underlayer and Contact Aligner}}
 
*[[Lift-Off with DUV Imaging + PMGI Underlayer|DUV Lift-Off: UV6 Imaging Resist + PMGI Underlayer]]
 
   
 
==Chemicals Stocked + Datasheets==
 
==Chemicals Stocked + Datasheets==
Line 333: Line 616:
   
 
*{{fl|AXP4000pb-Datasheet.pdf|AZP4000 (AZ4110, AZ4210, AZ4330)}}
 
*{{fl|AXP4000pb-Datasheet.pdf|AZP4000 (AZ4110, AZ4210, AZ4330)}}
  +
*{{Fl|Az_p4620_photoresist_data_package.pdf|AZ P4620}}
 
*{{fl|OCG825-Positive-Resist-Datasheet.pdf|OCG825}}
 
*{{fl|OCG825-Positive-Resist-Datasheet.pdf|OCG825}}
 
*{{fl|SPR220-Positive-Resist-Datasheet.pdf|SPR220 (SPR220-3, SPR220-7)}}
 
*{{fl|SPR220-Positive-Resist-Datasheet.pdf|SPR220 (SPR220-3, SPR220-7)}}
Line 388: Line 672:
 
;<div id="AntiReflectionCoatings"><big>Anti-Reflection Coatings</big></div>
 
;<div id="AntiReflectionCoatings"><big>Anti-Reflection Coatings</big></div>
   
*{{fl|XHRiC-Anti-Reflective-Coating.pdf|XHRiC (i-line)}}
+
*{{fl|XHRiC-Anti-Reflective-Coating.pdf|XHRiC-11 (i-line)}}
*{{fl|DUV42P-Anti-Reflective-Coating.pdf|DUV42P (DUV) (For AR2 replacement)}}
+
*{{fl|DUV42P-Anti-Reflective-Coating.pdf|DUV42P-6 (DUV) (For AR2 replacement)}}
 
*{{fl|DS-K101-304-Anti-Reflective-Coating.pdf|DS-K101-304 (DUV developable BARC)}}
 
*{{fl|DS-K101-304-Anti-Reflective-Coating.pdf|DS-K101-304 (DUV developable BARC)}}
   
Line 428: Line 712:
 
|}
 
|}
   
[[Category:Processing]]
+
[[Category: Processing]]
  +
[[category: Lithography]]
  +
[[category: Recipes]]

Latest revision as of 21:43, 16 February 2023

Table of Contents

Photolithography Processes

  1. UV Optical Lithography
  2. General Photolithography Techniques
    • Techniques for improving litho. or solving common photolith. problems.
  3. Lift-Off Recipes
    • Verified Recipes for lift-off using various photolith. tools
    • General educational description of this technique and it's limitations/considerations.
  4. E-beam Lithography
  5. Holography
    • For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square.
    • Recipes for silicon substrates are provided, and have been translated to other substrates by users.
    • Datasheets are provided with starting recipes and usage info.
  6. Edge-Bead Removal
    • Edge photoresist removal methods needed for clamp-based etchers
    • Improves resolution for contact lithography

Photolithography Chemicals/Materials

  1. Underlayers
    • These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.
    • Datasheets are provided.
  2. Anti-Reflection Coatings:
    • The Photoresist Recipes section contains recipes using these materials.
    • Bottom Anti-Reflection Coatings (BARC) are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes.
    • Datasheets are provided for reference on use of the materials.
  3. Contrast Enhancement Materials (CEM)
    • The Photoresist Recipes section contains recipes using these materials.
    • Used for resolution enhancement. Not for use in contact aligners, typically used on I-Line Steppers.
    • Datasheets provided with usage info.
  4. Adhesion Promoters
    • These are used to improve wetting of photoresists to your substrate.
    • Datasheets are provided on use of these materials.
  5. Low-K Spin-on Dielectrics
  6. Developers and Removers
    • Datasheets provided for reference.
    • Remover and Photoresist Strippers are used to dissolve PR during lift-off or after etching.

General Photolithography Techniques

HMDS Process for Improving Adhesion

  • Use these procedures if you are finding poor adhesion PR lifting-off), or for chemicals (like BHF) that attack the PR adhesion interface strongly.

Edge-Bead Removal Techniques

  • These techniques are required for loading full-wafers into etchers that use top-side clamps, to prevent photoresist from sticking to the clamp (and potentially destroying your wafer).
  • For contact lithography, this improves the proximity of the mask plate and sample, improving resolution. For some projection systems, such as the Maskless Aligner, EBR can help with autofocus issues.

Photoresist reflow (MicroChem)

  • To create slanted sidewalls or curved surfaces.

Photolithography Recipes

  • R: Recipe is available. Clicking this link will take you to the recipe.
  • A: Material is available for use, but no recipes are provided.

Click the tool title to go to recipes for that tool.

Click the photoresist title to get the datasheet, also found in Stocked Chemicals + Datasheets.

Photolithography Recipes
Contact Aligner Recipes Stepper Recipes Direct-Write Litho. Recipes
Positive Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ4110 R R A A R
AZ4210 R R A A A
AZ4330RS R R A A R
AZ4620 A A A A A
OCG 825-35CS A A A A A
SPR 955 CM-0.9 A R R R R
SPR 955 CM-1.8 A A R R A
SPR 220-3.0 R R R R R
SPR 220-7.0 R R R R A
THMR-IP3600 HP D A A R
UV6-0.8 R
UV210-0.3 R
UV26-2.5 A
Negative Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
AZ5214-EIR R R R R R
AZnLOF 2020 R R R R R
AZnLOF 2035 A A A A A
AZnLOF 2070 A A A A A
AZnLOF 5510 A A R R A
UVN30-0.8 R
SU-8 2005,2010,2015 A R A A A
SU-8 2075 A A A A R
NR9-1000,3000,6000PY R R A R A
Anti-Reflection Coatings SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)
XHRiC-11 A A A
DUV42-P R
DS-K101-304 R
SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)

Lift-Off Recipes

E-Beam Lithography Recipes (JEOL JBX-6300FS)

  • Under Development.

FIB Lithography Recipes (Raith Velion)

To Be Added

Automated Coat/Develop System Recipes (S-Cubed Flexi)

Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.

Ask Staff if you need a new recipe.
Coating Material Route/Chain Name: User: "UCSB Users" Spin Speed (krpm) Bake Temp Notes
DS-K101 Route DSK101's Develop Rate depends on Bake temp - you can use this to control undercut.

See: DSK Bake vs. Dev rate

Coat-DSK101[5K]-220C 5.0 220°C Requires: HP4=220°C

This is essentailly equivalent to DUV42P @ 220°C, must be dry etched.

Coat-DSK101[5K]-210C 5.0 210°C Requires: HP4=210°C
Coat-DSK101[5K]-200C 5.0 200°C Requires: HP4=200°C
Coat-DSK101[5K]-185C 5.0 185°C Requires: HP4=185°C
UV6-0.8 Route Coat-UV6[2K]-135C 2.0 135°C Requires: HP1=135°C
Coat-UV6[2.5K]-135C 2.5 135°C
Coat-UV6[3K]-135C 3.0 135°C
Coat-UV6[3.5K]-135C 3.5 135°C
Coat-UV6[4K]-135C 4.0 135°C
Coat-UV6[5K]-135C 5.0 135°C
Coat-UV6[6K]-135C 6.0 135°C
DS-K101 @ 220°C

+ UV6

Chain Coat-DSK101[5K]-220C-UV6[2K]-135C DSK: 5krpm

UV6: 2.0krpm

DSK: 220°C

UV6: 135°C

Requires:

– HP4=220°C

– HP1=135°C

Plan for ~10-15 min per wafer.

Coat-DSK101[5K]-220C-UV6[2.5K]-135C DSK: 5krpm

UV6: 2.5krpm

same as above same as above
Coat-DSK101[5K]-220C-UV6[3K]-135C DSK: 5krpm

UV6: 3.0krpm

same as above same as above
Coat-DSK101[5K]-220C-UV6[3.5K]-135C DSK: 5krpm

UV6: 3.5krpm

same as above same as above
Coat-DSK101[5K]-220C-UV6[4K]-135C DSK: 5krpm

UV6: 4.0krpm

same as above same as above
Coat-DSK101[5K]-220C-UV6[5K]-135C DSK: 5krpm

UV6: 5.0krpm

same as above same as above
Coat-DSK101[5K]-220C-UV6[6K]-135C DSK: 5krpm

UV6: 6.0krpm

same as above same as above
DS-K101 @ 185°C

+ UV6

Chain Coat-DSK101[5K]-185C-UV6[2K]-135C DSK: 5krpm

UV6: 2.0krpm

DSK: 185°C

UV6: 135°C

Requires:

– HP4=185°C

– HP1=135°C

Plan for ~10-15 min per wafer.

Coat-DSK101[5K]-185C-UV6[2.5K]-135C DSK: 5krpm

UV6: 2.5krpm

same as above same as above
Coat-DSK101[5K]-185C-UV6[3K]-135C DSK: 5krpm

UV6: 3.0krpm

same as above same as above
Coat-DSK101[5K]-185C-UV6[3.5K]-135C DSK: 5krpm

UV6: 3.5krpm

same as above same as above
Coat-DSK101[5K]-185C-UV6[4K]-135C DSK: 5krpm

UV6: 4.0krpm

same as above same as above
Coat-DSK101[5K]-185C-UV6[5K]-135C DSK: 5krpm

UV6: 5.0krpm

same as above same as above
Coat-DSK101[5K]-185C-UV6[6K]-135C DSK: 5krpm

UV6: 6.0krpm

same as above same as above
Hotplate Set Route SET-HP4-220C 220°C Hotplate 4 (top) between 218-222°C when done.
SET-HP4-210C 210°C
SET-HP4-200C 200°C
SET-HP4-185C 185*C

Holography Recipes

The Holography recipes here use the BARC layer XHRiC-11 & the high-res. I-Line photoresist THMR-IP3600HP-D.

Low-K Spin-On Dielectric Recipes

Chemicals Stocked + Datasheets

The following is a list of the lithography chemicals we stock in the lab, with links to the datasheets for each. The datasheets will often have important processing info such as spin-speed vs. thickness curves, typical process parameters, bake temps/times etc.

Positive Photoresists

i-line and broadband

DUV-248nm

Negative Photoresists

i-line and broadband

DUV-248nm

Underlayers
E-beam resists
Nanoimprinting
Contrast Enhancement Materials
Anti-Reflection Coatings
Adhesion Promoters
Spin-On Dielectrics

Low-K Spin-On Dielectrics such as Benzocyclobutane and Spin-on Glass

Developers
Photoresist Removers