Difference between revisions of "Chemical List - OLD 2018-09-05"
Jump to navigation
Jump to search
(Testing link to MSDS folder) |
(added link to Google drive #2 from DJ's MyDrive) |
||
Line 392: | Line 392: | ||
*[[media:Nitrogen MSDS.pdf|Nitrogen MSDS]] |
*[[media:Nitrogen MSDS.pdf|Nitrogen MSDS]] |
||
*[https://drive.google.com/drive/folders/1-_lvW6iv3456I0iQsbGtws_jQypEhOxa?usp=sharing MSDS Drive] |
*[https://drive.google.com/drive/folders/1-_lvW6iv3456I0iQsbGtws_jQypEhOxa?usp=sharing MSDS Drive] |
||
+ | *[https://drive.google.com/drive/folders/11U-rGNkEBThPeNd1Repr9eZtb1PMku0n?usp=sharing MSDS Drive #2 (DJ)] |
||
|- |
|- |
||
|} |
|} |
Revision as of 17:33, 4 September 2018
Below is a list of all chemicals authorized for use in the lab & links to the corresponding Material Safety Data Sheets (MSDS).
Only the chemicals that appear in bold are stocked by the lab for general use. All other listed chemicals have been authorized for individual users/companies to bring in for their own use.
MSDS sheets can be used to determine the concentrations and constituents of a particular chemical, in addition to safety, handling and emergency/exposure information. Please take time to look at the MSDS of the chemicals you use!
Acids
Bases
Lithography Chemicals
Please see the Recipes > Lithography > Chemical Datasheetspage for the datasheets, which include starting parameters for your fabrication processes.
Chemical | MSDS | Datasheet |
---|---|---|
1165 Stripper | 1165 Stripper MSDS | 1165 Stripper Datasheet |
Accuglass T-12B | Accuglass T-12B MSDS | |
AP 3000 Adhesion Promoter | AP 3000 Adhesion Promoter | |
AZ 300 MIF Developer | ||
AZ 300T Stripper | ||
AZ 400K Developer | ||
AZ 726 MIF Developer | ||
AZ EBR Edge Bead Remover | ||
AZ LOL 2000 Photoresist | ||
AZ nLOF 2020 Photoresist | ||
AZ nLOF 5510 Photoresist | ||
AZ NMP Stripper | AZ NMP RINSE | NMP Docs on MicroChem |
AZ P4110 Photoresist | ||
AZ P4210 Photoresist | ||
AZ P4330 RS Photoresist | ||
AZ P5214 EIR Photoresist | ||
CEM 365 IS | ||
Cyclotene 4024-40 BCB | ||
DS 2100 VCS Developer | ||
HMDS | ||
ma-N 2403 Photoresist | ||
mr-l-7000 Imprint Polymer | mr-l-7000 Datasheet | |
MCC-101 Developer | ||
Nano MMA Photoresist | ||
NR7-1500PY Photoresist | ||
NXR-1010 Imprint Resist | ||
NXR-1020 Imprint Resist | NXR-1020 Datasheet | |
OCG 825 Photoresist | ||
PMGI SF-series Photoresist | ||
PRX-127 Stripper | ||
RD6 Developer | ||
S1805 Photoresist | ||
SPR 220 Photoresist | ||
SPR 510A Photoresist | ||
SPR 518A Photoresist | ||
SPR 950-0.8 Photoresist | ||
SPR 955 CM | ||
SVC-14 Stripper | ||
Thinner P |