Recent changes

Jump to navigation Jump to search

Track the most recent changes to the wiki on this page.

Recent changes options Show last 50 | 100 | 250 | 500 changes in last 1 | 3 | 7 | 14 | 30 days
Hide registered users | Hide anonymous users | Hide my edits | Show bots | Show minor edits
Show new changes starting from 14:05, 5 June 2024
   
List of abbreviations:
N
This edit created a new page (also see list of new pages)
m
This is a minor edit
b
This edit was performed by a bot
(±123)
The page size changed by this number of bytes

5 June 2024

     10:59  MLA150 - Troubleshooting diffhist +3 John d talk contribs →‎Solutions for small substrates: --> sols for ALL substrate types Tag: Visual edit

4 June 2024

     15:59  Template:Announcements diffhist +408 Mehalana v talk contribs
     15:27  PECVD Recipes‎‎ 6 changes history +960 [Biljana‎ (6×)]
     
15:27 (cur | prev) +249 Biljana talk contribs →‎Low Stress Si3N4 [ICP-PECVD]
     
15:25 (cur | prev) +229 Biljana talk contribs →‎Si3N4 [ICP-PECVD]
     
15:24 (cur | prev) -1 Biljana talk contribs →‎High Deposition Rate SiO2 [ICP-PECVD]
     
15:24 (cur | prev) +241 Biljana talk contribs →‎High Deposition Rate SiO2 [ICP-PECVD]
     
15:22 (cur | prev) +31 Biljana talk contribs →‎Low Deposition Rate SiO2 [ICP-PECVD]
     
15:21 (cur | prev) +211 Biljana talk contribs →‎Low Deposition Rate SiO2 [ICP-PECVD]
     12:32  E-Beam 1 (Sharon)‎‎ 2 changes history -321 [Barreraz‎ (2×)]
     
12:32 (cur | prev) +4 Barreraz talk contribs →‎Documentation Tag: Visual edit
     
10:19 (cur | prev) -325 Barreraz talk contribs →‎About Tag: Visual edit
     12:31  (Upload log) [Barreraz‎ (3×)]
     
12:31 Barreraz talk contribs uploaded File:EB1 Rotation Fixture SOP 6-4-24.pdf
     
10:26 Barreraz talk contribs uploaded a new version of File:E-beam1.jpg
     
10:22 Barreraz talk contribs uploaded File:IMG 5450.jpg
     10:26  File:IMG 5450.jpg diffhist +3 Barreraz talk contribs Tag: Visual edit

3 June 2024

     14:44  (Upload log) [Barreraz‎ (2×)]
     
14:44 Barreraz talk contribs uploaded a new version of File:EB-3 operation instructions 5-22-24 V45.47.pdf
     
14:43 Barreraz talk contribs uploaded File:EB-1 operation instructions 6-3-24.pdf
     14:44  E-Beam 1 (Sharon) diffhist -1 Barreraz talk contribs →‎Documentation Tag: Visual edit

1 June 2024

     13:32  Template:Announcements‎‎ 2 changes history +440 [Mehalana v‎ (2×)]
     
13:32 (cur | prev) -77 Mehalana v talk contribs
     
13:29 (cur | prev) +517 Mehalana v talk contribs

31 May 2024

     15:53  Template:Tool2 diffhist -3 John d talk contribs Remove "N/A" when "recipes" section is not shown
     15:48  (Upload log) [John d‎ (2×)]
     
15:48 John d talk contribs uploaded a new version of File:DSEiii Example Bosch Etch 02.jpg(Added UCSB NanoFab watermark)
     
15:44 John d talk contribs uploaded File:DSEiii Example Bosch Etch 02.jpg
     15:46  DSEIII (PlasmaTherm/Deep Silicon Etcher) diffhist +615 John d talk contribs added beter Bosch example showing striations Tag: Visual edit

30 May 2024

     10:36  Template:Announcements diffhist +940 Mehalana v talk contribs

29 May 2024

     10:22  Template:Announcements diffhist -435 John d talk contribs removed old ASML annc, fixed sig on new ASMl annc

28 May 2024

     08:54  Plasma Clean (YES EcoClean) diffhist -1 Sawyer l talk contribs SOP Rev Tag: Visual edit
     08:53 Upload log Sawyer l talk contribs uploaded File:YES SOP Rev F.pdf(Revised)

24 May 2024

     11:17  Template:Announcements diffhist +254 Mehalana v talk contribs
     10:56  MLA Recipes‎‎ 15 changes history +370 [Biljana‎ (15×)]
     
10:56 (cur | prev) +194 Biljana talk contribs →‎Positive Resist (MLA150)
     
10:42 (cur | prev) -1 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:32 (cur | prev) +67 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:29 (cur | prev) +17 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:29 (cur | prev) +3 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:28 (cur | prev) +5 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:28 (cur | prev) +20 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:27 (cur | prev) -2 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:27 (cur | prev) +17 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:23 (cur | prev) +75 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:21 (cur | prev) +4 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:18 (cur | prev) +3 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:18 (cur | prev) +90 Biljana talk contribs →‎Greyscale Lithography (MLA150)
     
10:13 (cur | prev) -158 Biljana talk contribs →‎Positive Resist (MLA150)
     
10:10 (cur | prev) +36 Biljana talk contribs →‎Positive Resist (MLA150)

23 May 2024

     10:55  Template:Announcements‎‎ 2 changes history -216 [Mehalana v‎ (2×)]
     
10:55 (cur | prev) +2 Mehalana v talk contribs →‎Lab Access Changes: Symmetry App
     
10:54 (cur | prev) -218 Mehalana v talk contribs →‎Lab Access Changes: Symmetry App

22 May 2024

     16:59 User creation log User account Manojkumar talk contribs was created ‎
     16:30  E-Beam 3 (Temescal) diffhist +7 Barreraz talk contribs →‎Documentation Tag: Visual edit
     16:30  (Upload log) [Barreraz‎ (3×)]
     
16:30 Barreraz talk contribs uploaded File:EB-3 operation instructions 5-22-24 V45.47.pdf
     
16:28 Barreraz talk contribs uploaded a new version of File:EB-3 operation instructions 5-22-24.pdf
     
16:26 Barreraz talk contribs uploaded a new version of File:EB-3 operation instructions 5-22-24.pdf