Difference between revisions of "Surface Analysis (KLA/Tencor Surfscan)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(→‎Documentation: added info, and inof on LPC wafers)
Line 30: Line 30:
 
**''You must provide your own 2/3-inch Cassette.''
 
**''You must provide your own 2/3-inch Cassette.''
 
*[https://wiki.nanofab.ucsb.edu/w/images/4/4e/SURFSCAN_6200_Small_substrates.pdf Surfscan 6200 Small samples] *
 
*[https://wiki.nanofab.ucsb.edu/w/images/4/4e/SURFSCAN_6200_Small_substrates.pdf Surfscan 6200 Small samples] *
  +
*[https://wiki.nanofab.ucsb.edu/w/images/a/a7/SURFSCAN_6200_122123_small_substrates.pdf Surfscan 6200 Small samples, and 2inch and 3inch wafers] *
  +
  +
  +
 
**''You must water-mount your pieces to a 4-inch wafer.''
 
**''You must water-mount your pieces to a 4-inch wafer.''
 
*[[Wafer scanning process traveler|Wafer Particle Count - Process Traveler]]
 
*[[Wafer scanning process traveler|Wafer Particle Count - Process Traveler]]
 
**''This is the procedure Staff uses to calibrate particle counts on our deposition tools.''
 
**''This is the procedure Staff uses to calibrate particle counts on our deposition tools.''
  +
  +
https://wiki.nanofab.ucsb.edu/w/images/a/a7/SURFSCAN_6200_122123_small_substrates.pdf
   
 
===Other Documentation===
 
===Other Documentation===

Revision as of 17:41, 4 January 2024

Surface Analysis (KLA/Tencor Surfscan)
KLA.jpg
Location Bay 5
Tool Type Inspection, Test and Characterization
Manufacturer Tencor
Description Surface Analysis
KLA/Tencor Surfscan

Primary Supervisor Biljana Stamenic
(805) 893-4002
biljana@ece.ucsb.edu

Secondary Supervisor

Don Freeborn


Recipes N/A


About

This system uses a laser-based scattering method to count size and distribution of particles (or other scattering defects) on a flat wafer surface.

It can scan wafers in size from 4 to 8 inches. Piece-parts are more difficult but can be scanned with a custom recipe.

4-inch wafers are the most standard size to measure.

For measuring very low particle counts accurately, purchase "low particle count" (LPC) wafers from a Silicon wafer vendor, and keep the wafers in the case and clean at all times until use.

Documentation

Operating Procedures


https://wiki.nanofab.ucsb.edu/w/images/a/a7/SURFSCAN_6200_122123_small_substrates.pdf

Other Documentation

  • Operations Manual
    • For detailed measurement info, it is highly recommended that you read the manual.

Examples

A low-particle 4-inch wafer example:
Gain 4: Small Particles

(0.160µm – 1.60µm)

Gain 2: Large Particles

(1.60µm – 28.0µm)

Surfscan Low-Particle Example - G4.png Surfscan Low-Particle Example - G2.png
A high-particle 4-inch wafer example:
Gain 4: Small Particles

(0.160µm – 1.60µm)

Gain 2: Large Particles

(1.60µm – 28.0µm)

Surfscan - 230113A7 Gain4 high particles.jpg Surfscan 230113A7G2 after low particles.jpg