Difference between revisions of "Sputtering Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Line 12: Line 12:
   
 
=[[Sputter 3 (AJA ATC 2000-F)]]=
 
=[[Sputter 3 (AJA ATC 2000-F)]]=
=[[Sputter 4 (AJA ATC 2200-V)]]=
+
=[[Sputter 4 (AJA ATC 2200-V)]]=
  +
== W Deposition (Sputter 4) ==
  +
*[[media:|W Deposition Recipe]]
  +
 
=[[Sputter 5 (Lesker AXXIS)]]=
 
=[[Sputter 5 (Lesker AXXIS)]]=
 
=[[Ion Beam Deposition (Veeco NEXUS)]]=
 
=[[Ion Beam Deposition (Veeco NEXUS)]]=

Revision as of 16:09, 4 November 2013

Back to Vacuum Deposition Recipes.

Sputter 1 (Custom)

Sputter 2 (SFI Endeavor)

Al Deposition (Sputter 2)

AlNx Deposition (Sputter 2)

Au Deposition (Sputter 2)

TiO2 Deposition (Sputter 2)

Sputter 3 (AJA ATC 2000-F)

Sputter 4 (AJA ATC 2200-V)

W Deposition (Sputter 4)

  • [[media:|W Deposition Recipe]]

Sputter 5 (Lesker AXXIS)

Ion Beam Deposition (Veeco NEXUS)

IBD Calibrations Spreadsheet - Records of historical film depositions (rates, indices), Uniformity etc.

All users are required to enter their calibration deps (simple test deps only)


SiO2 deposition (IBD)

  • Refractive Index: ≈1.485
  • Rate: ≈6.1nm/min (users must calibrate this prior to critical deps)
  • Stress ≈ -320MPa (compressive)

Si3N4 deposition (IBD)

  • Refractive Index ≈ 2.01
  • Rate ≈ 4.5nm/min (users must calibrate this prior to critical deps)
  • Stress ≈ -1756MPa (compressive)

Ta2O5 deposition (IBD)

  • Refractive Index ≈ 2.10
  • Rate ≈7.8nm/min (users must calibrate this prior to critical deps)
  • Stress ≈ -140MPa (compressive)

TiO2 deposition (IBD)