User contributions
Jump to navigation
Jump to search
- 10:34, 26 January 2024 diff hist +128 Maskless Aligner (Heidelberg MLA150) Added quick start guide link current Tag: Visual edit
- 10:32, 26 January 2024 diff hist 0 N File:MLA150 Quick Start Rev A.pdf current
- 14:44, 9 January 2024 diff hist 0 File:DUV Flood Expose SOP Rev C.pdf Sawyer l uploaded a new version of File:DUV Flood Expose SOP Rev C.pdf current
- 15:40, 4 January 2024 diff hist -1 DUV Flood Expose SOP Rev current Tag: Visual edit
- 15:39, 4 January 2024 diff hist 0 N File:DUV Flood Expose SOP Rev C.pdf
- 14:57, 30 October 2023 diff hist 0 File:ADT SOP Rev J.pdf Sawyer l uploaded a new version of File:ADT SOP Rev J.pdf current
- 14:56, 30 October 2023 diff hist 0 File:ADT SOP Rev J.pdf Sawyer l uploaded a new version of File:ADT SOP Rev J.pdf
- 11:06, 30 October 2023 diff hist -1 Plasma Activation (EVG 810) SOP rev current Tag: Visual edit
- 11:06, 30 October 2023 diff hist 0 N File:EVG Plasma Activation SOP Rev E.pdf current
- 15:11, 17 October 2023 diff hist 0 Dicing Saw (ADT) New SOP rev current Tag: Visual edit
- 15:10, 17 October 2023 diff hist 0 N File:ADT SOP Rev J.pdf
- 14:26, 28 September 2023 diff hist 0 File:RIE 2 SOP Rev D.pdf Sawyer l uploaded a new version of File:RIE 2 SOP Rev D.pdf current
- 08:24, 13 September 2023 diff hist +74 Dicing Saw (ADT) Added UV tape TDS link Tag: Visual edit
- 08:23, 13 September 2023 diff hist 0 N File:Ultron 1042R Film specs.pdf current
- 08:23, 13 September 2023 diff hist +165 Dicing Saw (ADT) Updated About section Tag: Visual edit
- 09:17, 29 August 2023 diff hist +53 UV Ozone Reactor Added an SOP current Tag: Visual edit
- 09:16, 29 August 2023 diff hist 0 File:UV Ozone SOP Rev A.pdf Sawyer l uploaded a new version of File:UV Ozone SOP Rev A.pdf current
- 08:42, 29 August 2023 diff hist 0 N File:UV Ozone SOP Rev A.pdf
- 11:31, 25 August 2023 diff hist -1 E-Beam 2 (Custom) SOP rev (minor) current Tag: Visual edit
- 11:31, 25 August 2023 diff hist 0 N File:EB2 SOP Rev H.pdf current
- 10:35, 24 August 2023 diff hist +55 Packaging Recipes →Recommended Dicing Parameters: Updated material table with 2C blades, other minor edits Tag: Visual edit
- 10:52, 22 August 2023 diff hist 0 File:ICP -1 Standard Etch Recipes.pdf Sawyer l uploaded a new version of File:ICP -1 Standard Etch Recipes.pdf current
- 11:11, 17 August 2023 diff hist -5 ICP Etch 1 (Panasonic E646V) Tag: Visual edit
- 11:10, 17 August 2023 diff hist +109 ICP Etch 1 (Panasonic E646V) Added standard etch recipes to documentation section Tag: Visual edit
- 11:09, 17 August 2023 diff hist 0 N File:ICP -1 Standard Etch Recipes.pdf
- 06:33, 3 August 2023 diff hist -1 Dicing Saw (ADT) SOP rev Tag: Visual edit
- 06:32, 3 August 2023 diff hist 0 N File:ADT SOP Rev I.pdf current
- 09:34, 2 August 2023 diff hist -1 Contact Aligner (SUSS MA-6) Minor SOP edit (typo) Tag: Visual edit
- 09:33, 2 August 2023 diff hist 0 File:MA-6 SOP Rev D.pdf Sawyer l uploaded a new version of File:MA-6 SOP Rev D.pdf current
- 07:55, 21 July 2023 diff hist -1 RIE 2 (MRC) Updated SOP current Tag: Visual edit
- 07:54, 21 July 2023 diff hist 0 N File:RIE 2 SOP Rev D.pdf
- 09:41, 26 May 2023 diff hist +122 Suss Aligners (SUSS MJB-3) Add IR Alignment Mode Conversion SOP Tag: Visual edit
- 09:38, 26 May 2023 diff hist +104 Suss Aligners (SUSS MJB-3) Added IR Camera SOP Tag: Visual edit
- 09:36, 26 May 2023 diff hist 0 File:MJB 3 IR Camera SOP Rev B.pdf Sawyer l uploaded a new version of File:MJB 3 IR Camera SOP Rev B.pdf current
- 10:35, 10 May 2023 diff hist 0 E-Beam 2 (Custom) SOP rev Tag: Visual edit
- 10:34, 10 May 2023 diff hist 0 N File:EB2 SOP Rev G.pdf current
- 08:46, 28 March 2023 diff hist 0 Dicing Saw (ADT) Updated tool location
- 11:54, 21 March 2023 diff hist -5 ICP Etch 1 (Panasonic E646V) Gas change SOP, minor rev Tag: Visual edit
- 11:52, 21 March 2023 diff hist 0 File:ICP -1 Gas Change N2-He-N2.pdf Sawyer l uploaded a new version of File:ICP -1 Gas Change N2-He-N2.pdf current
- 11:51, 21 March 2023 diff hist 0 N File:ICP -1 Gas Change CHF3-Ar.pdf current
- 11:50, 21 March 2023 diff hist 0 File:ICP -1 Gas Change CF4-SF6-CF4.pdf Sawyer l uploaded a new version of File:ICP -1 Gas Change CF4-SF6-CF4.pdf current
- 14:03, 16 March 2023 diff hist -310 Template:Announcements
- 14:00, 16 March 2023 diff hist 0 Dicing Saw (ADT) SOP Rev Tag: Visual edit
- 13:59, 16 March 2023 diff hist 0 N File:ADT SOP Rev H.pdf current
- 08:36, 10 March 2023 diff hist -1 RIE 2 (MRC) SOP rev Tag: Visual edit
- 08:32, 10 March 2023 diff hist 0 N File:RIE 2 SOP Rev C.pdf current
- 14:57, 8 March 2023 diff hist +20 CAIBE (Oxford Ion Mill) Update SOP rev Tag: Visual edit
- 14:56, 8 March 2023 diff hist +21 Atomic Layer Deposition (Oxford FlexAL) Update SOP rev current Tag: Visual edit
- 14:55, 8 March 2023 diff hist 0 N File:Oxford Cluster Tool Operating Instructions Rev B.pdf current
- 10:26, 2 March 2023 diff hist 0 File:EB2 SOP Rev F.pdf Sawyer l uploaded a new version of File:EB2 SOP Rev F.pdf current
- 14:38, 15 February 2023 diff hist -2 E-Beam 2 (Custom) SOP updated Tag: Visual edit
- 14:37, 15 February 2023 diff hist 0 N File:EB2 SOP Rev F.pdf
- 11:31, 8 February 2023 diff hist -6 Plasma Clean (YES EcoClean) SOP rev (minor) Tag: Visual edit
- 11:30, 8 February 2023 diff hist 0 N File:YES SOP Rev E.pdf current
- 12:30, 23 November 2022 diff hist 0 Dicing Saw (ADT) Updated SOP Tag: Visual edit
- 12:29, 23 November 2022 diff hist 0 N File:ADT SOP Rev G.pdf current
- 07:22, 18 October 2022 diff hist +183 Contact Aligner (SUSS MA-6) Added additional tool specs, including BSA objective spacing Tag: Visual edit
- 10:38, 7 October 2022 diff hist +5 Maskless Aligner (Heidelberg MLA150) Updated SOP Tag: Visual edit
- 10:37, 7 October 2022 diff hist 0 N File:MLA150 SOP Rev L (LS).docx.pdf current
- 12:06, 15 September 2022 diff hist 0 Plasma Activation (EVG 810) Updated SOP Tag: Visual edit
- 12:06, 15 September 2022 diff hist 0 N File:EVG Plasma Activation SOP Rev D.pdf current
- 14:35, 8 September 2022 diff hist 0 E-Beam 2 (Custom) Updated photo Tag: Visual edit
- 14:11, 8 September 2022 diff hist 0 N File:IMG 5388.jpg current
- 10:09, 8 September 2022 diff hist -2 UV Ozone Reactor Updated tool template Tag: Visual edit
- 10:07, 8 September 2022 diff hist +404 UV Ozone Reactor About section updated Tag: Visual edit
- 08:42, 6 September 2022 diff hist +270 E-Beam 2 (Custom) Tool description/specs Tag: Visual edit
- 13:32, 31 August 2022 diff hist +224 Template:Announcements Add MLA service info
- 13:28, 25 August 2022 diff hist -9 ICP Etch 1 (Panasonic E646V) Tag: Visual edit
- 13:28, 25 August 2022 diff hist 0 N File:ICP -1 Wafer Type Change.pdf current
- 11:21, 25 August 2022 diff hist +121 ICP Etch 1 (Panasonic E646V) Add wafer type change SOP Tag: Visual edit
- 09:06, 7 July 2022 diff hist 0 Dicing Saw (ADT) updated SOP Tag: Visual edit
- 09:05, 7 July 2022 diff hist 0 N File:ADT SOP Rev F.pdf current
- 11:02, 26 April 2022 diff hist +117 Dicing Saw (ADT) Add tape station SOP Tag: Visual edit
- 11:01, 26 April 2022 diff hist 0 N File:Tape Station SOP Rev A.pdf current
- 11:29, 22 March 2022 diff hist 0 E-Beam 2 (Custom) SOP rev Tag: Visual edit
- 11:28, 22 March 2022 diff hist 0 N File:EB2 SOP Rev D.pdf current
- 13:48, 21 March 2022 diff hist -5 Dicing Saw (ADT) SOP rev Tag: Visual edit
- 13:48, 21 March 2022 diff hist 0 N File:ADT SOP Rev E.pdf current
- 08:45, 1 March 2022 diff hist +347 Contact Aligner (SUSS MA-6) Added chuck and mask sizes Tag: Visual edit
- 14:10, 2 February 2022 diff hist -5 Maskless Aligner (Heidelberg MLA150) SOP update Tag: Visual edit
- 14:09, 2 February 2022 diff hist 0 N File:MLA150 SOP Rev K (LS).pdf current
- 11:16, 5 January 2022 diff hist +4 Maskless Aligner (Heidelberg MLA150) SOP update Tag: Visual edit
- 11:15, 5 January 2022 diff hist 0 N File:MLA150 SOP Rev J (LS).docx.pdf current
- 10:59, 3 January 2022 diff hist -3 E-Beam 2 (Custom) Updated SOP Tag: Visual edit
- 10:58, 3 January 2022 diff hist 0 N File:EB2 SOP Rev C.pdf current