User contributions
Jump to navigation
Jump to search
- 17:03, 21 March 2024 diff hist +58 Stepper Recipes →Negative Resist (ASML DUV): UVN dev time current Tag: Visual edit
- 15:05, 20 March 2024 diff hist +149 MLA150 - Troubleshooting →Causes: added OAF driving off wafer current Tag: Visual edit
- 15:04, 20 March 2024 diff hist +172 Direct-Write Lithography Recipes →Maskless Aligner (Heidelberg MLA150): link to Troubleshooting/OOFocus section Tag: Visual edit
- 17:27, 14 March 2024 diff hist +429 Direct-Write Lithography Recipes →Maskless Aligner (Heidelberg MLA150): added FEM comment Tag: Visual edit
- 17:17, 14 March 2024 diff hist -29 Direct-Write Lithography Recipes →Greyscale Lithography (MLA150): deleted Flood Expose column Tag: Visual edit
- 03:27, 13 March 2024 diff hist -1,261 Stepper 3 (ASML DUV) removed Wiki-hosted ASML procedures, linked to gDrive procedures (access restricted) Tag: Visual edit
- 16:16, 12 March 2024 diff hist +62 Nanofab Job Postings →Process/Wafer Fab Engineer Level 3 (Staff position): not reviewing apps Tag: Visual edit
- 16:13, 12 March 2024 diff hist +48 Main Page link to Job Postings current Tag: Visual edit
- 15:47, 12 March 2024 diff hist -1,402 Template:Announcements deleted duplicates and old >2wk old annc
- 09:54, 11 March 2024 diff hist +271 ICP Etching Recipes →Through Silicon Via (TSV) etch (DSEiii): added note on TSV rocess - discuss with staff before running Tag: Visual edit
- 09:42, 11 March 2024 diff hist +9 m Staff List →Process Group current Tag: Visual edit
- 09:42, 11 March 2024 diff hist +75 Staff List →Process Group: added mission statement Tag: Visual edit
- 10:19, 9 March 2024 diff hist -1 IBD: Calibrating Optical Thickness Corrected 1050/1100 FP correction current Tag: Visual edit
- 12:54, 7 March 2024 diff hist +861 Nanofab Job Postings added R&D2 pos Tag: Visual edit
- 11:15, 7 March 2024 diff hist +526 Tube Furnace (Tystar 8300) process limits added current Tag: Visual edit
- 18:43, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Ridge Etch using Oxford PlasmaPro 100 Cobra - 2021-09-08.pdf John d uploaded a new version of File:Oxford Etcher - InP Ridge Etch using Oxford PlasmaPro 100 Cobra - 2021-09-08.pdf current
- 18:35, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf John d uploaded a new version of File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf current
- 18:33, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf John d uploaded a new version of File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf
- 18:22, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf John d uploaded a new version of File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf
- 16:25, 4 March 2024 diff hist +47 m Packaging Recipes →Dicing Saw Recipes (ADT 7100)
- 13:55, 1 March 2024 diff hist +148 Oxygen Plasma System Recipes →N2/O2 Recipes: note that wafers get hotter than recipe name indicates. Tag: Visual edit
- 12:07, 1 March 2024 diff hist +3 Suss Aligners (SUSS MJB-3) →IR Aligner: removed hammamatsu current Tag: Visual edit
- 12:06, 1 March 2024 diff hist +285 Suss Aligners (SUSS MJB-3) →IR Aligner: added photo of front-to-back IR camera alignment inspection Tag: Visual edit
- 12:04, 1 March 2024 diff hist +81 N File:IR Alignment check 01 - crop.png current
- 11:52, 1 March 2024 diff hist +85 Tool List →Optical Microscopy: link to MJB-IR IR scope current Tag: Visual edit
- 11:30, 1 March 2024 diff hist +51 N File:OlympusDSX1000.jpg New photo with non-proprietary image. current
- 21:08, 29 February 2024 diff hist +19 m Field Emission SEM 2 (JEOL IT800SHL) current Tag: Visual edit
- 21:07, 29 February 2024 diff hist +419 SEM 1 (JEOL IT800SHL) →Operating Procedures: linked to CalTech stuf correction vid with tops Tag: Visual edit
- 13:46, 29 February 2024 diff hist +132 Oxygen Plasma System Recipes →N2/O2 effect on Gold contacts & Substrate Temperature: minor additions to clarify gold optical absorption Tag: Visual edit
- 12:29, 27 February 2024 diff hist +135 Direct-Write Lithography Recipes →Greyscale Lithography (MLA150): added link to GS page Tag: Visual edit
- 17:24, 23 February 2024 diff hist +14 Template:Announcements re-added "startfeed" <startfeed />
- 12:20, 23 February 2024 diff hist -23 Template:Announcements moved RIE5 below DSE and ICP1
- 12:18, 23 February 2024 diff hist -589 Template:Announcements deleted EB4, other tools up. Updated ICP1 and DSE from emails.
- 12:16, 23 February 2024 diff hist +15 m Critical Point Dryer current Tag: Visual edit
- 12:15, 23 February 2024 diff hist +182 Critical Point Dryer mention tool removed, link to QSF CPD Tag: Visual edit
- 12:13, 23 February 2024 diff hist -93 Tool List →Measurement & Characterization: deleted goniometer Tag: Visual edit
- 12:12, 23 February 2024 diff hist +189 Plasma Clean (Gasonics 2000) mention tool removed, link to YES and Pan1 Ashing current Tag: Visual edit
- 12:10, 23 February 2024 diff hist +95 SEM 1 (JEOL IT800SHL) mentioned nabity litho Tag: Visual edit
- 12:08, 23 February 2024 diff hist -19 Tool List →Direct-Write Lithography: link to SEM 1 Tag: Visual edit
- 12:08, 23 February 2024 diff hist -4 Tool List →Lithography: removed "FEI" text Tag: Visual edit
- 12:50, 16 February 2024 diff hist +69 Calculators + Utilities →Python Scripts: made scripts into header 2 Tag: Visual edit
- 15:17, 15 February 2024 diff hist +12 m DSEIII (PlasmaTherm/Deep Silicon Etcher) added model number current
- 15:15, 15 February 2024 diff hist +191 DSEIII (PlasmaTherm/Deep Silicon Etcher) added example SEM Tag: Visual edit
- 15:12, 15 February 2024 diff hist -5 Category:Inspection, Test and Characterization fixed link current Tag: Redirect target changed
- 15:10, 15 February 2024 diff hist +1 Main Page fixed Metro/Test link Tag: Visual edit
- 15:06, 15 February 2024 diff hist -6 m ICP Etching Recipes →High Rate Bosch Etch (DSEIII) Tag: Visual edit: Switched
- 15:05, 15 February 2024 diff hist +291 ICP Etching Recipes →High Rate Bosch Etch (DSEIII): added SEM of Bosch etched posts Tag: Visual edit
- 15:00, 15 February 2024 diff hist +77 N File:DSEiii Bosch Ecth SEM Example 01.png current
- 14:58, 14 February 2024 diff hist +1 m Template:Announcements →E-Beam #4 (CHA) - UP
- 14:58, 14 February 2024 diff hist -149 Template:Announcements EB4 up