Difference between revisions of "Nanofab Staff Internal Pages"
Jump to navigation
Jump to search
(added NanoFab IT, and linked to NanoFab-it OnDema filter/page) |
Mehalana v (talk | contribs) |
||
(27 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | This page is intended for NanoFab Staff, internal. |
|
+ | ==Equipment Group== |
||
− | ==Video Training procedures== |
||
+ | *[[Equipment Group - Video Training Procedures|Video Training Procedures]] - How to record, edit and publish a video training. |
||
− | *[[Video Training - Introduction (Internal)|Intro]]: general overview of the recording and online training methods. |
||
− | *Recording your Training Video: |
||
− | **Synchronized recording for minimal-effort recordings. |
||
− | **[[GoPro Hero8 Black (Internal)|GoPro Hero8 Black]] - used for first-person recording. |
||
− | **[[Sony Handycam - Record your Training (Internal)|Sony Handycam]] - used for recording computer screens |
||
− | **[[Video Training: Recording a Windows 10 Computer Screen|Windows Screen-Recording]] - for wide-screen monitors |
||
− | *[[Video Training: Editing on the Video Training Workstation|Upload/Edit your files on the Video Editing workstation]] |
||
− | *[[Video Training: Uploading to GauchoCast/Panopto (Internal)|Uploading your files to GauchoCast/Panopto]] |
||
− | *[[Video Training: Hosting with Zoom and GacuhoCast/Panopto|Hosting a Video Training with Zoom and GacuhoCast/Panopto]] |
||
==Process Group== |
==Process Group== |
||
Line 19: | Line 11: | ||
**''Includes [[Process Group - Billing Instructions#Supplies Costs|Supplies Costs]].'' |
**''Includes [[Process Group - Billing Instructions#Supplies Costs|Supplies Costs]].'' |
||
*[[ASML Stepper 3 Dicing Guide Programming|ASML Dicing Guide Programming]] - how to print dicing guides on a wafer |
*[[ASML Stepper 3 Dicing Guide Programming|ASML Dicing Guide Programming]] - how to print dicing guides on a wafer |
||
+ | *[[Process Group - Process Control Data|Process Control Data]] - all the links to process calibration/repeatability data in one place. |
||
− | == |
+ | ==NanoFab IT== |
+ | ''Computers, Networks, FTP/File-Sync etc.'' |
||
+ | |||
+ | *Instructions+Procedures can be found in ''gDrive > Facilities Group > Computer Systems'' |
||
+ | *'''Unifi Network SDN''' |
||
+ | *#Network Hardware Maintenance |
||
+ | *##Add/Remover User for Unifi Network Controller |
||
+ | *#Switch Maintenance |
||
+ | *##Restart |
||
+ | *##Reset |
||
+ | *#Add/Replace new Switch visit [https://store.ui.com/us/en store.ui.com/us/en] we are using follow switch below |
||
+ | *##switching-standard 48/24/16 ports |
||
+ | *##switching-aggregation 8 Ports |
||
+ | *##Flex Mini 5 Ports |
||
+ | *#Add/ Replace Fail SFP Receiver When searching in the Maintenance Shop, locate the bin labeled SFP Receiver & look for 1000 BASE-LX 1310-nm SFP Receiver |
||
+ | *#Add/ Replace Fail Fiber Cable When searching in the Maintenance Shop, locate the bin labeled Fiber LC to SC and search for the Optical Fiber Patch Cable. |
||
+ | *#Add/Replace the Ethernet patch We have four length of the patch cable 3/5/10/15 ft located in the Tel/Data RM#1117 In both case please update the [https://docs.google.com/spreadsheets/d/1iPc4Sxh8ge2mc0hhXlqS6ofckT8nzfrw9QcWefoLMa8/edit?usp=sharing IT Hardware Log] Sheet: '''Eth Ports''', '''Endpoints''' |
||
+ | *##Patch Pannel to Switch Label format : <<sw-name>>-<<port-number>> |
||
+ | *##System to Wall Port Lable format : Nanofile-Network 10.1.1.1/16 |
||
+ | *'''Synology''' |
||
+ | *#Active Backup for Business |
||
+ | *##Add new device |
||
+ | *##Add new server |
||
+ | *##Restore a device |
||
+ | *#Create a new Network Share Folder |
||
+ | *#Add a Device to Apple Time Machine |
||
+ | *#Server Maintenance |
||
+ | *'''Nanofiles''' |
||
+ | *#Failover (CARP) |
||
+ | *#Restart |
||
+ | *#Restore |
||
+ | *#[[Nanofab-IT - Add Device to Network|Add Device to Network]] |
||
+ | *#Nanofile Sync |
||
+ | *##Add a new Device |
||
+ | *###Make sure Device is connected to Nanofiles |
||
+ | *###Connect the Network drive \\nanofiles\staff |
||
+ | *###Copy '''grsync''' directory from the network and paste it to '''c:\''' drive |
||
+ | *###Run the '''Init.bat''' in the grsync directory, press enter twice (make sure do not enter any password) besides remember the part of the stored SSH key |
||
+ | *###open the sync.bat in notepad change |
||
+ | *####'''<code>SET MACHINE=[host-name]</code>''' |
||
+ | *####create a nanofiles - userdata directory in public folder Note : In case of Drive change use this syntax '''<code>/cygdrive/[drive-letter]/</code>''' |
||
+ | *##Replace a Device |
||
+ | *#Generating New WireGard VPN Credentials |
||
+ | *##Server-Side |
||
+ | *###Commend for generating the keys: <code>cd /etc/wiregard</code> <code>wg genkey | tee privatekey_<<replace it with username>> | wg pubkey > publickey_<<replace it with username>></code> |
||
+ | *###Add a new line in /etc/hostname.wg0: <code>wgpeer <<public_key_of_new_user>> wgaip 10.1.10.XXX/32</code> |
||
+ | *###Service Restart: <code>sh /etc/netstart wg0</code> |
||
+ | *##Client-Side |
||
+ | *###'''Generate the a new file with .conf extension''' <code>[Interface]</code> <code>PrivateKey = <<privatekey_of_new_user>></code> <code>Address = 10.1.10.XXX/32</code> <code>DNS = 10.1.1.1</code> <code>[Peer]</code> <code>PublicKey = hHngYmJZUxRfLAmCxhC00m80hjsNDKl4LKV4iDYN+TY= </code> <code>AllowedIPs = 10.1.0.0/16</code> <code>Endpoint = nanofiles1.ece.ucsb.edu:5900</code> <code>PersistentKeepalive = 25</code> |
||
+ | |||
+ | *'''Signupmonkey''' |
||
+ | **Failover |
||
+ | **Restart |
||
+ | **Restore |
||
+ | *'''RechargeApp''' |
||
+ | **Failover |
||
+ | **Restart |
||
+ | **Restore |
||
+ | *'''Nanofabserver2''' |
||
+ | **Restart |
||
+ | **Restore |
||
+ | *'''DataGrove''' |
||
+ | **Restore Backup |
||
+ | **#Login to nanofiles2 |
||
+ | **#Get the list of the Snapshots: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup snapshots</code> |
||
+ | **#To view files within a snapshot: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup ls -l [snapshort-id] | grep "[dir-path-to-search]"</code> |
||
+ | **#To restore a single directory: <code>restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup restore [snapshort-id] --target [dir-path-save-restore-data] --include [dir-path-to-restore]</code> |
||
+ | **Note: Please replace all value in [square-bracket] as mention |
||
+ | *'''NanoFab Wiki''' |
||
+ | **Restart |
||
+ | **Restore |
||
+ | *'''NanoFab Server UPS''' |
||
+ | **Battery Test |
||
+ | *'''Utilities Software''' |
||
+ | *#LogMeIn |
||
+ | *##Add a new Device |
||
+ | *##Add a new user |
||
+ | *##Remove a External/Internal User <br /> |
||
+ | |||
+ | ==Administration== |
||
+ | |||
+ | *[[Nanofab New User Onboarding|Nanofab New User Onboarding - UCSB Users]] - To-do list for new internal-UCSB users |
||
+ | *[[Nanofab New User Onboarding - External Users]] - To-do list for new External users traveling from elsewhere |
||
+ | |||
+ | ==Useful UCSB Pages== |
||
+ | |||
+ | *[https://www.dfss.ucsb.edu/facilities-management/work-request Facilities Work Requests] - Here's where you report facilities repair requests, like replacing light bulbs, building problems (doors, elevators) etc. |
||
+ | |||
+ | ==Old / Defunct== |
||
+ | ''Old pages we don't use on the Wiki anymore, but are kept for possible utility later on.'' |
||
*[[Process Group - Lab Stocking/Supplies Tasks|Lab Stocking/Supplies Tasks]] - Not needed anymore 2021-02 |
*[[Process Group - Lab Stocking/Supplies Tasks|Lab Stocking/Supplies Tasks]] - Not needed anymore 2021-02 |
||
Line 26: | Line 108: | ||
**New [[Old Deposition Data - NastaziaM 2021-11-22|Deposition Data - NastaziaM 2021-11-22]] - combo of old & new links. Can probably be safely deleted. |
**New [[Old Deposition Data - NastaziaM 2021-11-22|Deposition Data - NastaziaM 2021-11-22]] - combo of old & new links. Can probably be safely deleted. |
||
**[[Deposition Data - temporary 2021-12-15|Deposition Data - temporary 2021-12-15]] - staging for new links, copied to PECVD/Sputter Recipes pages on 2021-12-15. This can probably be safely deleted. |
**[[Deposition Data - temporary 2021-12-15|Deposition Data - temporary 2021-12-15]] - staging for new links, copied to PECVD/Sputter Recipes pages on 2021-12-15. This can probably be safely deleted. |
||
− | |||
− | == NanoFab IT == |
||
− | Computers, Networks, FTP/File-Sync etc. |
||
− | |||
− | * [https://ucsbnanofab.app.ondema.tech/jobs/wall/opportunities?kw=NanoFab-it '''Jobs List for NanoFab-IT tasks (OnDema)'''] |
Revision as of 13:14, 31 January 2024
This page is intended for NanoFab Staff, internal.
Equipment Group
- Video Training Procedures - How to record, edit and publish a video training.
Process Group
- Job Tracking - pages to organize and track our remote 'fab service jobs
- Billing Instructions (RechargeApp) - info on entering billing into RechargeApp.
- Includes Supplies Costs.
- ASML Dicing Guide Programming - how to print dicing guides on a wafer
- Process Control Data - all the links to process calibration/repeatability data in one place.
NanoFab IT
Computers, Networks, FTP/File-Sync etc.
- Instructions+Procedures can be found in gDrive > Facilities Group > Computer Systems
- Unifi Network SDN
- Network Hardware Maintenance
- Add/Remover User for Unifi Network Controller
- Switch Maintenance
- Restart
- Reset
- Add/Replace new Switch visit store.ui.com/us/en we are using follow switch below
- switching-standard 48/24/16 ports
- switching-aggregation 8 Ports
- Flex Mini 5 Ports
- Add/ Replace Fail SFP Receiver When searching in the Maintenance Shop, locate the bin labeled SFP Receiver & look for 1000 BASE-LX 1310-nm SFP Receiver
- Add/ Replace Fail Fiber Cable When searching in the Maintenance Shop, locate the bin labeled Fiber LC to SC and search for the Optical Fiber Patch Cable.
- Add/Replace the Ethernet patch We have four length of the patch cable 3/5/10/15 ft located in the Tel/Data RM#1117 In both case please update the IT Hardware Log Sheet: Eth Ports, Endpoints
- Patch Pannel to Switch Label format : <<sw-name>>-<<port-number>>
- System to Wall Port Lable format : Nanofile-Network 10.1.1.1/16
- Network Hardware Maintenance
- Synology
- Active Backup for Business
- Add new device
- Add new server
- Restore a device
- Create a new Network Share Folder
- Add a Device to Apple Time Machine
- Server Maintenance
- Active Backup for Business
- Nanofiles
- Failover (CARP)
- Restart
- Restore
- Add Device to Network
- Nanofile Sync
- Add a new Device
- Make sure Device is connected to Nanofiles
- Connect the Network drive \\nanofiles\staff
- Copy grsync directory from the network and paste it to c:\ drive
- Run the Init.bat in the grsync directory, press enter twice (make sure do not enter any password) besides remember the part of the stored SSH key
- open the sync.bat in notepad change
SET MACHINE=[host-name]
- create a nanofiles - userdata directory in public folder Note : In case of Drive change use this syntax
/cygdrive/[drive-letter]/
- Replace a Device
- Add a new Device
- Generating New WireGard VPN Credentials
- Server-Side
- Commend for generating the keys:
cd /etc/wiregard
wg genkey | tee privatekey_<<replace it with username>> | wg pubkey > publickey_<<replace it with username>>
- Add a new line in /etc/hostname.wg0:
wgpeer <<public_key_of_new_user>> wgaip 10.1.10.XXX/32
- Service Restart:
sh /etc/netstart wg0
- Commend for generating the keys:
- Client-Side
- Generate the a new file with .conf extension
[Interface]
PrivateKey = <<privatekey_of_new_user>>
Address = 10.1.10.XXX/32
DNS = 10.1.1.1
[Peer]
PublicKey = hHngYmJZUxRfLAmCxhC00m80hjsNDKl4LKV4iDYN+TY=
AllowedIPs = 10.1.0.0/16
Endpoint = nanofiles1.ece.ucsb.edu:5900
PersistentKeepalive = 25
- Generate the a new file with .conf extension
- Server-Side
- Signupmonkey
- Failover
- Restart
- Restore
- RechargeApp
- Failover
- Restart
- Restore
- Nanofabserver2
- Restart
- Restore
- DataGrove
- Restore Backup
- Login to nanofiles2
- Get the list of the Snapshots:
restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup snapshots
- To view files within a snapshot:
restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup ls -l [snapshort-id] | grep "[dir-path-to-search]"
- To restore a single directory:
restic -p /etc/restic-pwd --repo sftp:restic@datagrove:/srv/backup restore [snapshort-id] --target [dir-path-save-restore-data] --include [dir-path-to-restore]
- Note: Please replace all value in [square-bracket] as mention
- Restore Backup
- NanoFab Wiki
- Restart
- Restore
- NanoFab Server UPS
- Battery Test
- Utilities Software
- LogMeIn
- Add a new Device
- Add a new user
- Remove a External/Internal User
- LogMeIn
Administration
- Nanofab New User Onboarding - UCSB Users - To-do list for new internal-UCSB users
- Nanofab New User Onboarding - External Users - To-do list for new External users traveling from elsewhere
Useful UCSB Pages
- Facilities Work Requests - Here's where you report facilities repair requests, like replacing light bulbs, building problems (doors, elevators) etc.
Old / Defunct
Old pages we don't use on the Wiki anymore, but are kept for possible utility later on.
- Lab Stocking/Supplies Tasks - Not needed anymore 2021-02
- Old Deposition Data - 2021-12-15 - removed from main Dep pages
- New Deposition Data - NastaziaM 2021-11-22 - combo of old & new links. Can probably be safely deleted.
- Deposition Data - temporary 2021-12-15 - staging for new links, copied to PECVD/Sputter Recipes pages on 2021-12-15. This can probably be safely deleted.