User contributions
Jump to navigation
Jump to search
- 12:51, 4 January 2022 diff hist +191 Packaging Recipes →Calculated Blade Exposures: added blade exposure calc Tag: Visual edit
- 12:50, 4 January 2022 diff hist +37 N File:ADT Dicing - Blade Exposure diagram.png current
- 12:41, 4 January 2022 diff hist +1,753 Packaging Recipes →Dicing Saw Recipes (ADT 7100): added Dicing Tips Tag: Visual edit
- 11:29, 4 January 2022 diff hist +35 Tool List →Inspection, Test and Characterization: rearranged, moved "other properties" to end, renamed "Surfscan" to "particle counts" Tag: Visual edit
- 11:13, 4 January 2022 diff hist +79 Test Data of etching SiO2 with CHF3/CF4 →Alternate Data (not updated since 2019) Tag: Visual edit
- 11:12, 4 January 2022 diff hist +209 Test Data of etching SiO2 with CHF3/CF4 pasted link to alternate etch data Tag: Visual edit
- 11:11, 4 January 2022 diff hist -158 ICP Etching Recipes →Historical Data (SiO2 Etch, Panasonic 2): removed 2nd data table Tag: Visual edit
- 13:36, 3 January 2022 diff hist -693 Template:Announcements Deleted Flu vacc. mandate
- 13:34, 3 January 2022 diff hist +4 Template:Announcements →Jan 2022 UCSB COVID Protocols
- 13:33, 3 January 2022 diff hist +1,993 Template:Announcements pasted useful UCSB Jan COVID policiues
- 16:10, 21 December 2021 diff hist 0 File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png John d uploaded a new version of File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png current
- 16:09, 21 December 2021 diff hist +36 MLA150 - Troubleshooting →Out Of Focus Exposures: "features less than 100µm" Tag: Visual edit
- 11:52, 21 December 2021 diff hist -5 m MLA150 - Troubleshooting →Out Of Focus Exposures Tag: Visual edit
- 11:52, 21 December 2021 diff hist +285 MLA150 - Troubleshooting →Out Of Focus Exposures: inserted image of out-of-focus exposure Tag: Visual edit
- 11:50, 21 December 2021 diff hist +87 N File:Out of Focus Exposures - Carl Peterson (Krisnamoorthy Group, 2021-12).png
- 11:39, 21 December 2021 diff hist -3 m MLA150 - Troubleshooting fix bullets
- 11:38, 21 December 2021 diff hist -2 m MLA150 - Troubleshooting →Unexpected Behavior Tag: Visual edit
- 11:34, 21 December 2021 diff hist -38 MLA150 - Troubleshooting rearranged sections, increased heading level to 1 & 2 Tag: Visual edit
- 11:07, 21 December 2021 diff hist +62 MLA150 - Troubleshooting Tag: Visual edit
- 00:26, 16 December 2021 diff hist +182 Nanofab Staff Internal Pages →Old / Defunct Tag: Visual edit
- 00:21, 16 December 2021 diff hist +94 m Ion Beam Deposition (Veeco NEXUS) →Recipes Tag: Visual edit
- 00:19, 16 December 2021 diff hist -424 Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): deleted IBD Cals spreadsheet Tag: Visual edit
- 00:18, 16 December 2021 diff hist +426 Old Deposition Data - 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): added IBD Cals spreadsheet current Tag: Visual edit
- 00:15, 16 December 2021 diff hist -2 Old Deposition Data - 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): promoted to Page Title
- 00:15, 16 December 2021 diff hist +359 Old Deposition Data - 2021-12-15 →SiO2 deposition (IBD): added old IBD data Tag: Visual edit
- 00:12, 16 December 2021 diff hist +6,481 Old Deposition Data - 2021-12-15 pasted Old (2021-12-15) IBD recipe data
- 00:11, 16 December 2021 diff hist -613 Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS): pasted Nastazia M's new data
- 00:09, 16 December 2021 diff hist -12,460 PECVD Recipes pasted NastaziaM's new data links
- 00:07, 16 December 2021 diff hist +167 Deposition Data - temporary 2021-12-15 →Standard Cleaning Procedure (IBD): cleaning current Tag: Visual edit
- 00:05, 16 December 2021 diff hist +575 Deposition Data - temporary 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): pasted SiOxNy data
- 00:03, 16 December 2021 diff hist +2,234 Deposition Data - temporary 2021-12-15 →Ion Beam Deposition (Veeco NEXUS): updated IBD Tag: Visual edit
- 23:49, 15 December 2021 diff hist +1,751 Deposition Data - temporary 2021-12-15 New data links Tag: Visual edit
- 07:35, 15 December 2021 diff hist +24,157 N Old Deposition Data - 2021-12-15 Created page with "OLD Data: Copied on 2021-12-14 {{recipes|Vacuum Deposition}} =PECVD 1 (PlasmaTherm 790)= ====Historical Particulate Data==== *[https://docs.google.com/spreadsheets/d..." Tag: Visual edit: Switched
- 07:35, 15 December 2021 diff hist +107 Nanofab Staff Internal Pages →Old / Defunct Tag: Visual edit
- 07:32, 15 December 2021 diff hist -11,328 Deposition Data - temporary 2021-12-15
- 07:31, 15 December 2021 diff hist +26 Deposition Data - temporary 2021-12-15 Tag: Visual edit
- 07:31, 15 December 2021 diff hist +24,158 N Deposition Data - temporary 2021-12-15 pasted old data
- 07:30, 15 December 2021 diff hist +83 Nanofab Staff Internal Pages →Old / Defunct: temp. link to dep data Tag: Visual edit
- 06:10, 15 December 2021 diff hist +1,908 MLA150 - Troubleshooting →Out Of Focus Exposures: Debugging section Tag: Visual edit
- 09:31, 14 December 2021 diff hist +598 Old Deposition Data - NastaziaM 2021-11-22 modified PECVD1 and PECVD 1 for same titles as old data current Tag: Visual edit
- 09:20, 14 December 2021 diff hist +24,230 Old Deposition Data - NastaziaM 2021-11-22 pasted all old data from https://wiki.nanotech.ucsb.edu/wiki/PECVD_Recipes Tag: Visual edit
- 09:02, 14 December 2021 diff hist +10 m Nanofab Staff Internal Pages Tag: Visual edit
- 09:21, 11 December 2021 diff hist +115 m ICP Etching Recipes →Si Deep RIE (PlasmaTherm/Bosch Etch): linnks to new DSE & FL_ICP recipes Tag: Visual edit
- 09:20, 11 December 2021 diff hist +331 ICP Etching Recipes →Oxford ICP Etcher (PlasmaPro 100 Cobra): links for GaAs, GaSb Tag: Visual edit
- 12:16, 8 December 2021 diff hist +504 N MA6 Backside Alignment - Allowed Mark Locations 100-mm BSA chuck with cutouts measurements current Tag: Visual edit
- 12:15, 8 December 2021 diff hist +67 N File:MA-6 4-inch BSA chuck - 2631 - measurements.jpg current
- 12:12, 8 December 2021 diff hist +53 Contact Aligner (SUSS MA-6) →Documentation: link to "backside alignment - allowed mark locations" Tag: Visual edit
- 12:10, 8 December 2021 diff hist +2 m Contact Aligner (SUSS MA-6) minor wording Tag: Visual edit
- 12:11, 7 December 2021 diff hist 0 m Template:Announcements →New COVID Protocols: minor formatting
- 12:10, 7 December 2021 diff hist -1,191 Template:Announcements delete old Weekly-Testing & COVID-Protocols & OxfordICP messages