Difference between revisions of "Dry Etching Recipes"
Jump to navigation
Jump to search
Line 2: | Line 2: | ||
{| border="1" class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" |
{| border="1" class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" |
||
|- bgcolor="#D0E7FF" |
|- bgcolor="#D0E7FF" |
||
− | ! width="725" height="45" colspan=" |
+ | ! width="725" height="45" colspan="16" | <div style="font-size: 150%;">Dry Etching Recipes</div> |
|- bgcolor="#D0E7FF" |
|- bgcolor="#D0E7FF" |
||
| <!-- INTENTIONALLY LEFT BLANK --> |
| <!-- INTENTIONALLY LEFT BLANK --> |
||
Line 8: | Line 8: | ||
! width="300" bgcolor="#D0E7FF" align="center" colspan="4" | '''[[ICP Etching Recipes|ICP Etching]]''' |
! width="300" bgcolor="#D0E7FF" align="center" colspan="4" | '''[[ICP Etching Recipes|ICP Etching]]''' |
||
! bgcolor="#D0E7FF" align="center" colspan="4"|'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
! bgcolor="#D0E7FF" align="center" colspan="4"|'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
||
− | ! bgcolor="#D0E7FF" align="center" colspan=" |
+ | ! bgcolor="#D0E7FF" align="center" colspan="3" |'''[[Other Dry Etcher Recipes|Other Dry Etchers]]''' |
|- |
|- |
||
! width="65" bgcolor="#D0E7FF" align="center" | '''Material''' |
! width="65" bgcolor="#D0E7FF" align="center" | '''Material''' |
||
Line 15: | Line 15: | ||
| width="65" bgcolor="#DAF1FF" | [[RIE 3 (MRC)|RIE 3<br> (MRC)]] |
| width="65" bgcolor="#DAF1FF" | [[RIE 3 (MRC)|RIE 3<br> (MRC)]] |
||
| width="100" bgcolor="#DAF1FF" | [[RIE 5 (PlasmaTherm)|RIE 5<br>(PlasmaTherm)]] |
| width="100" bgcolor="#DAF1FF" | [[RIE 5 (PlasmaTherm)|RIE 5<br>(PlasmaTherm)]] |
||
− | | width=" |
+ | | width="100" bgcolor="#DAF1FF" | [[Si Deep RIE (PlasmaTherm/Bosch Etch)|Si Deep RIE<br>(PTI/Bosch)]] |
− | | width="120" bgcolor="#DAF1FF" | [[ICP Etch 1 (Panasonic E626I)|ICP Etch 1<br>(Panasonic |
+ | | width="120" bgcolor="#DAF1FF" | [[ICP Etch 1 (Panasonic E626I)|ICP Etch 1<br>(Panasonic 1)]] |
− | | width="120" bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic |
+ | | width="120" bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic 2)]] |
| width="85" bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]] |
| width="85" bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]] |
||
| width="85" bgcolor="#DAF1FF" | [[Ashers (Technics PEII)|Ashers<br>(Technics PEII)]] |
| width="85" bgcolor="#DAF1FF" | [[Ashers (Technics PEII)|Ashers<br>(Technics PEII)]] |
||
Line 25: | Line 25: | ||
| width="85" bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]] |
| width="85" bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]] |
||
| width="85" bgcolor="#DAF1FF" | [[Vapor HF Etch|Vapor HF Etch<br>(uETCH)]] |
| width="85" bgcolor="#DAF1FF" | [[Vapor HF Etch|Vapor HF Etch<br>(uETCH)]] |
||
+ | | width="85" bgcolor="#DAF1FF" | [[Vapor HF Etch|CAIBE<br>(Oxford)]] |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | Al |
! bgcolor="#D0E7FF" align="center" | Al |
||
Line 40: | Line 41: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|- |
|- |
||
Line 57: | Line 59: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | Cr |
! bgcolor="#D0E7FF" align="center" | Cr |
||
Line 72: | Line 75: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|- |
|- |
||
Line 88: | Line 92: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
Line 104: | Line 109: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|- |
|- |
||
Line 120: | Line 126: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
Line 136: | Line 143: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|- |
|- |
||
Line 152: | Line 160: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
Line 168: | Line 177: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|- |
|- |
||
Line 184: | Line 194: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
Line 200: | Line 211: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|- |
|- |
||
Line 215: | Line 227: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 233: | Line 246: | ||
| |
| |
||
| {{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}} |
| {{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}} |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | SiN |
! bgcolor="#D0E7FF" align="center" | SiN |
||
Line 249: | Line 263: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | SiOxNy |
! bgcolor="#D0E7FF" align="center" | SiOxNy |
||
Line 265: | Line 280: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | Ta<sub>2</sub>O<sub>5</sub> |
! bgcolor="#D0E7FF" align="center" | Ta<sub>2</sub>O<sub>5</sub> |
||
Line 280: | Line 296: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
Line 297: | Line 314: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | TiN |
! bgcolor="#D0E7FF" align="center" | TiN |
||
Line 313: | Line 331: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | ZnO<sub>2</sub> |
! bgcolor="#D0E7FF" align="center" | ZnO<sub>2</sub> |
||
Line 329: | Line 348: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | ZrO<sub>2</sub> |
! bgcolor="#D0E7FF" align="center" | ZrO<sub>2</sub> |
||
Line 345: | Line 365: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | GaAs |
! bgcolor="#D0E7FF" align="center" | GaAs |
||
Line 361: | Line 382: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | AlGaAs |
! bgcolor="#D0E7FF" align="center" | AlGaAs |
||
Line 375: | Line 397: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 393: | Line 416: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | InGaAsP |
! bgcolor="#D0E7FF" align="center" | InGaAsP |
||
Line 409: | Line 433: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | InP |
! bgcolor="#D0E7FF" align="center" | InP |
||
Line 425: | Line 450: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | GaN |
! bgcolor="#D0E7FF" align="center" | GaN |
||
Line 441: | Line 467: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | AlGaN |
! bgcolor="#D0E7FF" align="center" | AlGaN |
||
Line 457: | Line 484: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | AlN |
! bgcolor="#D0E7FF" align="center" | AlN |
||
Line 471: | Line 499: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 487: | Line 516: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 503: | Line 533: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 521: | Line 552: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | GaSb |
! bgcolor="#D0E7FF" align="center" | GaSb |
||
Line 535: | Line 567: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 551: | Line 584: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 567: | Line 601: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 584: | Line 619: | ||
| |
| |
||
| {{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
| {{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
||
+ | | |
||
| |
| |
||
|- |
|- |
||
Line 601: | Line 637: | ||
| |
| |
||
| |
| |
||
+ | | |
||
|-bgcolor ="#EEFFFF" |
|-bgcolor ="#EEFFFF" |
||
! bgcolor="#D0E7FF" align="center" | Sapphire |
! bgcolor="#D0E7FF" align="center" | Sapphire |
||
Line 615: | Line 652: | ||
| |
| |
||
| |
| |
||
+ | | |
||
| |
| |
||
| |
| |
||
Line 633: | Line 671: | ||
| bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]] |
| bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]] |
||
| bgcolor="#DAF1FF" | [[Vapor HF Etch|Vapor HF Etch<br>(uETCH)]] |
| bgcolor="#DAF1FF" | [[Vapor HF Etch|Vapor HF Etch<br>(uETCH)]] |
||
+ | | bgcolor="#DAF1FF" | [[Vapor HF Etch|CAIBE<br>(Oxford)]] |
||
|} |
|} |
||
Revision as of 14:57, 9 July 2015
- R = Recipe is available. Clicking this link will take you to the recipe.
- A = Material is available for use, but no recipes are provided.
Dry Etching Recipes
| |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RIE Etching | ICP Etching | Oxygen Plasma Systems | Other Dry Etchers | ||||||||||||
Material | RIE 1 (Custom) |
RIE 2 (MRC) |
RIE 3 (MRC) |
RIE 5 (PlasmaTherm) |
Si Deep RIE (PTI/Bosch) |
ICP Etch 1 (Panasonic 1) |
ICP Etch 2 (Panasonic 2) |
ICP-Etch (Unaxis VLR) |
Ashers (Technics PEII) |
Plasma Clean (Gasonics 2000) |
UV Ozone Reactor | Plasma Activation (EVG 810) |
XeF2 Etch (Xetch) |
Vapor HF Etch (uETCH) |
CAIBE (Oxford) |
Al | R | R | |||||||||||||
Ti | R | A | |||||||||||||
Cr | A | R | A | ||||||||||||
Ge | |||||||||||||||
Ag | |||||||||||||||
Ru | |||||||||||||||
Mo | |||||||||||||||
Ta | |||||||||||||||
W-TiW | R | A | |||||||||||||
Al2O3 | |||||||||||||||
HfO2 | |||||||||||||||
ITO | R | ||||||||||||||
SiO2 | R | R | R | ||||||||||||
SiN | R | R | |||||||||||||
SiOxNy | |||||||||||||||
Ta2O5 | |||||||||||||||
TiO2 | |||||||||||||||
TiN | |||||||||||||||
ZnO2 | |||||||||||||||
ZrO2 | |||||||||||||||
GaAs | R | R | R | R | |||||||||||
AlGaAs | R | R | R | ||||||||||||
InGaAlAs | R | R | |||||||||||||
InGaAsP | R | ||||||||||||||
InP | R | R | |||||||||||||
GaN | R | R | R | ||||||||||||
AlGaN | |||||||||||||||
AlN | |||||||||||||||
GaN | |||||||||||||||
AlGaN | |||||||||||||||
AlN | |||||||||||||||
GaSb | |||||||||||||||
CdZnTe | R | ||||||||||||||
ZnSe | |||||||||||||||
Si | R | R | |||||||||||||
SiC | R | A | |||||||||||||
Sapphire | R | A | |||||||||||||
Material | RIE 1 (Custom) |
RIE 2 (MRC) |
RIE 3 (MRC) |
RIE 5 (PlasmaTherm) |
Si Deep RIE (PlasmaTherm/Bosch Etch) |
ICP Etch 1 (Panasonic E626I) |
ICP Etch 2 (Panasonic E640) |
ICP-Etch (Unaxis VLR) |
Ashers (Technics PEII) |
Plasma Clean (Gasonics 2000) |
UV Ozone Reactor | Plasma Activation (EVG 810) |
XeF2 Etch (Xetch) |
Vapor HF Etch (uETCH) |
CAIBE (Oxford) |