Search results
Jump to navigation
Jump to search
Page title matches
- |type = Dry Etch |description = ICP Etching and Ashing Multi-Chamber Tool4 KB (697 words) - 15:18, 7 February 2024
- #REDIRECT [[ICP Etch 1 (Panasonic E646V)]]42 bytes (6 words) - 15:18, 7 February 2024
Page text matches
- #REDIRECT [[ICP Etch 1 (Panasonic E646V)]]42 bytes (6 words) - 15:18, 7 February 2024
- | colspan="5" |Florine ICP: 3.8mT, 50/800W, CHF3/CF4=10/30sccm, and Time=90 sec |Etch Rate (nm/min)264 bytes (34 words) - 18:33, 2 February 2021
- | colspan="6" |Florine ICP: 3.8mT, 50/800W, CHF3/CF4=10/30sccm, and Time=90 sec |Etch Rate (nm/min)322 bytes (44 words) - 18:30, 2 February 2021
- | colspan="6" |Florine ICP: 3.8mT, 50/800W, CHF3/CF4=10/30sccm, and Time=90 sec |Etch Rate (nm/min)322 bytes (44 words) - 18:37, 2 February 2021
- ...E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" ! colspan="6" |'''[[ICP Etching Recipes|ICP Etching]]'''14 KB (1,875 words) - 15:31, 7 February 2024
- | colspan="5" |ICP#2: 0.5Pa, 50/500W, CHF3/CF4/O2=35/5/10sccm, time=210 sec |Etch Rate (nm/min)707 bytes (100 words) - 18:26, 6 April 2020
- ==Sample Size Effect on Etch Rate (Oxford ICP Etcher)== ...affect the etch profile - ie. '''etches are still smooth and vertical, but etch rate varies with sample area.'''2 KB (256 words) - 16:05, 20 March 2023
- |type = Dry Etch ...EcoClean)|YES EcoClean]] and [[ICP Etch 1 (Panasonic E646V)|Panasonic ICP #1 Ashing]] are the process replacements.''' ''-- DJ 2023''1 KB (159 words) - 12:12, 23 February 2024
- |type = Dry Etch |location=Bay 12 KB (313 words) - 16:31, 29 September 2022
- |type = Dry Etch |description = ICP Etching and Ashing Multi-Chamber Tool4 KB (697 words) - 15:18, 7 February 2024
- ==[[PECVD Recipes#PECVD 1 .28PlasmaTherm 790.29|PECVD #1 (PlasmaTherm 790)]]== ...s/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=1270764394 PECVD#1: Plots of all data]10 KB (1,497 words) - 12:03, 24 April 2024
- | colspan="7" |Fluorine ICP: 3.8mT, 50/'''900W''', CHF3/CF4=10/30sccm, time='''90 sec''' |Etch Rate (nm/min)5 KB (758 words) - 15:03, 9 January 2023
- |+'''ICP#1 Recipe:''' |'''Etch Rate (nm/min)'''7 KB (936 words) - 09:54, 12 January 2023
- ...Indium Phosphide Etch Verification procedure|Unaxis PM1: Indium Phosphide Etch Verification Procedure]] *[[ProcessGroup: ICP|ICP#1/2: SiO2 Etch Verification Procedure]]2 KB (297 words) - 16:46, 11 September 2023
- ==Process Control Data - InP Ridge Etch (Oxford ICP Etcher)== ...tepper #2 (AutoStep 200)]] & [[ICP Etch 1 (Panasonic E626I)|Panasonic ICP #1]]8 KB (1,214 words) - 15:38, 12 January 2023
- ==Data - InP Ridge Etch (Unaxis VLR)== ...tepper #2 (AutoStep 200)]] & [[ICP Etch 1 (Panasonic E626I)|Panasonic ICP #1]]5 KB (717 words) - 18:41, 21 November 2022
- |location=Bay 1 |description = High Density ICP PECVD3 KB (454 words) - 10:35, 23 May 2023
- ...cedure for performing an etch with laser monitor endpoint on the Panasonic ICP etchers.'' ## The locations on ICP#1 and ICP#2 are different.6 KB (876 words) - 14:23, 13 June 2019
- | colspan="5" |'''ICP#2''': 0.5Pa, 50/900W, CHF3/CF4=10/30 sccm, time=210 sec !Etch Rate (nm/min)7 KB (976 words) - 13:15, 11 January 2023
- * [[ICP Etch 1 (Panasonic E626I)]]716 bytes (86 words) - 09:59, 28 October 2021