Difference between revisions of "Wafer Cleaver (PELCO Flip-Scribe)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(new tool page)
 
(changed room --> ESB 1111)
 
(4 intermediate revisions by 2 users not shown)
Line 3: Line 3:
 
|type = Packaging
 
|type = Packaging
 
|super= Brian Thibeault
 
|super= Brian Thibeault
|location=ESB 1106?
+
|location=ESB 1111
 
|description = Manual Cleaving
 
|description = Manual Cleaving
  +
|model = [https://www.tedpella.com/Material-Sciences_html/PELCO-FlipScribe.aspx PELCO Flip-Scribe]
|model = LatticeAx
 
|manufacturer = PELCO
+
|manufacturer = [https://www.tedpella.com TedPella Inc.]
 
|materials =
 
|materials =
 
|toolid=
 
|toolid=
 
}}
 
}}
 
==About==
 
==About==
The LatticeAx is a manual cleaving system, with a diamond tip that scribes along the underside of the part/wafer. The user manually drags the part across the diamond scribe, using the guides and stops to push the part in a controlled, straight line.
+
The Flip-Scribe is a manual scribe+break cleaving system, with a diamond tip that scribes along the underside of the part/wafer. The user manually drags the part across the diamond scribe, using the guides and stops to push the part in a controlled, straight line.
 
Manual breaking tools are provided to perform the break after scribing.
 
Manual breaking tools are provided to perform the break after scribing.
  +
  +
Can scribe/break ~350µm thick sapphire wafers. Thicker/more difficult to cleave parts should be thinned down on the [[Mechanical Polisher (Allied)|Allied Polisher]] before cleaving.
   
 
==Detailed Specifications==
 
==Detailed Specifications==
   
* Wafer/Parts Sizes: 4" down to ~10mm
+
*Wafer/Parts Sizes: 4" down to ~10mm
  +
*Digital microscope w/ laptop for finer alignment
  +
*~100µm alignment accuracy
   
 
==Operating Procedures==
 
==Operating Procedures==
   
* [[LatticeAx SOP]] - To be added
+
*Flipscribe [[LatticeAx SOP|SOP]] - To be added
   
   
 
==Recipes==
 
==Recipes==
   
*Recipes > Packaging > '''[[Packaging Recipes#LatticeAx|To Be Added]]'''
+
*Recipes > Packaging > '''[[Packaging Recipes#LatticeAx|''To Be Added'']]'''
   
Be sure to also see the recipes for protecting your sample from dicing dust on the [[Packaging Recipes]] page.
+
Be sure to also see the recipes for protecting your sample from dicing dust on the [[Packaging Recipes|'''Packaging Recipes''']] page.

Latest revision as of 07:57, 13 December 2022

Wafer Cleaver (PELCO Flip-Scribe)
LatticeAx.jpg
Tool Type Packaging
Location ESB 1111
Supervisor Brian Thibeault
Supervisor Phone (805) 893-2268
Supervisor E-Mail thibeault@ece.ucsb.edu
Description Manual Cleaving
Manufacturer TedPella Inc.
Model PELCO Flip-Scribe


About

The Flip-Scribe is a manual scribe+break cleaving system, with a diamond tip that scribes along the underside of the part/wafer. The user manually drags the part across the diamond scribe, using the guides and stops to push the part in a controlled, straight line. Manual breaking tools are provided to perform the break after scribing.

Can scribe/break ~350µm thick sapphire wafers. Thicker/more difficult to cleave parts should be thinned down on the Allied Polisher before cleaving.

Detailed Specifications

  • Wafer/Parts Sizes: 4" down to ~10mm
  • Digital microscope w/ laptop for finer alignment
  • ~100µm alignment accuracy

Operating Procedures

  • Flipscribe SOP - To be added


Recipes

Be sure to also see the recipes for protecting your sample from dicing dust on the Packaging Recipes page.