Difference between revisions of "Vacuum Deposition Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
m (→‎Process Control Data: smaller font)
 
(171 intermediate revisions by 8 users not shown)
Line 1: Line 1:
  +
===[[Process Group - Process Control Data#Deposition .28Process Control Data.29|<u>Process Control Data</u>]]===
{| border="1" class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;"
 
  +
<small>''See [[Process Group - Process Control Data#Deposition .28Process Control Data.29|linked page]] for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.''</small>
|- bgcolor="#D0E7FF"
 
  +
! width="1675" height="45" colspan="18" | <div style="font-size: 150%;">Vacuum Deposition Recipes</div>
 
  +
===Deposition Tools/Materials Table===
|- bgcolor="#D0E7FF"
 
  +
| <!-- INTENTIONALLY LEFT BLANK --> <br>
 
  +
*<small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small>
! bgcolor="#D0E7FF" align="center" colspan="4" | '''[[E-Beam Evaporation Recipes|E-Beam Evaporation]]'''
 
  +
*<small>'''A''': ''Material is available for use, but no recipes are provided.''</small>
! bgcolor="#D0E7FF" align="center" colspan="5" | '''[[Sputtering Recipes|Sputtering]]'''
 
  +
! bgcolor="#D0E7FF" align="center" colspan="2" | '''[[Thermal Evaporation Recipes|Thermal Evaporation]]'''
 
  +
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1"
! bgcolor="#D0E7FF" align="center" colspan="3" | '''[[PECVD Recipes|Plasma Enhanced Chemical<br>Vapor Deposition (PECVD)]]'''
 
  +
|- bgcolor="#d0e7ff"
! width="90" bgcolor="#D0E7FF" align="center" | '''[[Atomic Layer Deposition Recipes|Atomic Layer Deposition]]'''
 
! width="100" bgcolor="#D0E7FF" align="center" | '''[[Ion Beam Deposition Recipes|Ion Beam Deposition (IBD)]]'''
+
! colspan="16" width="1675" height="45" |<div style="font-size: 150%;">Vacuum Deposition Recipes</div>
  +
|- bgcolor="#d0e7ff"
! width="100" bgcolor="#D0E7FF" align="center" | '''[[Molecular Vapor Deposition Recipes|Molecular Vapor Deposition]]'''
 
  +
|<!-- INTENTIONALLY LEFT BLANK --><br>
  +
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[E-Beam Evaporation Recipes|E-Beam Evaporation]]'''
  +
! colspan="4" |'''[[Sputtering Recipes|Sputtering]]'''
  +
! colspan="2" bgcolor="#d0e7ff" align="center" |'''[[Thermal Evaporation Recipes|Thermal Evaporation]]'''
  +
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[PECVD Recipes|Plasma Enhanced Chemical<br>Vapor Deposition (PECVD)]]'''
  +
! width="90" bgcolor="#d0e7ff" align="center" |'''[[Atomic Layer Deposition Recipes|Atomic Layer Deposition]]'''
  +
! width="80" bgcolor="#d0e7ff" align="center" |'''[[Molecular Vapor Deposition Recipes|Molecular Vapor Deposition]]'''
 
|-
 
|-
! width="20" bgcolor="#D0E7FF" align="center" | '''Material'''
+
! width="20" bgcolor="#d0e7ff" align="center" |'''Material'''
| width="65" bgcolor="#DAF1FF" | [[E-Beam_Evaporation_Recipes#E-Beam_1 (Sharon)|E-Beam 1 (Sharon)]]
+
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]]
| width="65" bgcolor="#DAF1FF" | [[E-Beam_Evaporation_Recipes#E-Beam 2 (Custom)|E-Beam 2 (Custom)]]
+
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]]
| width="65" bgcolor="#DAF1FF" | [[E-Beam_Evaporation_Recipes#E-Beam 3 (Temescal)|E-Beam 3 (Temescal)]]
+
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]]
| width="65" bgcolor="#DAF1FF" | [[E-Beam_Evaporation_Recipes#E-Beam 4 (CHA)|E-Beam 4 (CHA)]]
+
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter 1 (Custom)|Sputter 1 (Custom)]]
+
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29|Sputter 3<br>(AJA ATC 2000-F)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter 2 (SFI Endeavor)|Sputter 2<br>(SFI Endeavor)]]
+
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(AJA ATC 2200-V)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter 3 (ATC 2000-F)|Sputter 3<br>(ATC 2000-F)]]
+
| width="65" bgcolor="#daf1ff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_5_.28AJA_ATC_2200-V.29 Sputter 5 (AJA ATC 2200-V)]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter 4 (ATC 2200-V)|Sputter 4<br>(ATC 2200-V)]]
+
| width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]]
| width="65" bgcolor="#DAF1FF" | [[Sputtering Recipes#Sputter 5 (Lesker AXXIS)|Sputter 5 (Lesker AXXIS)]]
+
| width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]]
| width="65" bgcolor="#DAF1FF" | [[Thermal Evaporation Recipes#Thermal Evap 1|Thermal Evap 1]]
+
| width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]]
| width="65" bgcolor="#DAF1FF" | [[Thermal Evaporation Recipes#Thermal Evap 2 (Solder)|Thermal Evap 2 (Solder)]]
+
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]]
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#PECVD 1 (PlasmaTherm 790)|PECVD 1<br>(PlasmaTherm 790)]]
+
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]]
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#PECVD 2 (Advanced Vacuum)|PECVD 2<br>(Advanced Vacuum)]]
+
| width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]]
| width="65" bgcolor="#DAF1FF" | [[PECVD Recipes#Unaxis VLR ICP-PECVD|Unaxis VLR ICP-PECVD]]
+
| width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAL)]]
| width="65" bgcolor="#DAF1FF" | [[Atomic Layer Deposition (Oxford FlexAL)|Atomic Layer Deposition (Tool)]]
+
| width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
| width="65" bgcolor="#DAF1FF" | [[Ion Beam Deposition (Veeco NEXUS)|Ion Beam<br>Deposition (Tool)]]
 
| width="65" bgcolor="#DAF1FF" | [[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ag
+
! bgcolor="#d0e7ff" align="center" |Ag
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E3}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E4}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Al
+
! bgcolor="#d0e7ff" align="center" |Al
  +
|{{Al/E1}}
| <br>
 
| <br>
+
|<br>
  +
|{{Al/E3}}
| <br>
 
  +
|{{Al/E4}}
| <br>
 
  +
|[[Sputtering Recipes|A]]
| <br>
 
  +
|{{rl|Sputtering Recipes|Al Deposition (Sputter 4)}}
| <br>
 
| <br>
+
|<br>
  +
|<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]]
| <br>
 
  +
|[[Thermal Evaporation Recipes|A]]
| <br>
 
  +
|[[Thermal Evaporation Recipes|A]]
| <br>
 
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
 
| <br>
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Al<sub>2</sub>O<sub>3</sub>
+
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E2}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Al2O3 Deposition (Sputter 4)}}
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Al2O3_deposition_.28IBD.29 R]
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|Al2O3 deposition (ALD CHAMBER 3)}}
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | AlN
+
! bgcolor="#d0e7ff" align="center" |AlN
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
  +
|[[Sputtering Recipes|A]]
| <br>
 
  +
|[[Sputtering Recipes|A]]
| <br>
 
| <br>
+
|<br>
  +
|[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]]
| <br>
 
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
  +
|{{rl|Atomic Layer Deposition Recipes|AlN deposition (ALD CHAMBER 3)}}
| <br>
 
| <br>
+
|<br>
| <br>
 
| <br>
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Au
+
! bgcolor="#d0e7ff" align="center" |Au
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E3}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E4}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}}
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | B
+
! bgcolor="#d0e7ff" align="center" |B
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
 
| <br>
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Co
+
! bgcolor="#d0e7ff" align="center" |C
  +
| bgcolor="#eeffff" align="center" |{{rl|E-Beam Evaporation Recipes|Materials Table (E-Beam #1)}}
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" align="center" |
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Cr
+
! bgcolor="#d0e7ff" align="center" |CeO<sub>2</sub>
| <br>
+
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |{{rl|E-Beam Evaporation Recipes|E-Beam 2 (Custom)|CeO<sub>2</sub> deposition (E-Beam 2)}}
| <br>
 
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
+
| bgcolor="#eeffff" |<br>
| <br>
 
| <br>
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Cu
+
! bgcolor="#d0e7ff" align="center" |Co
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E4}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|R]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Fe
+
! bgcolor="#d0e7ff" align="center" |Cr
  +
|{{Al/E1}}
| <br>
 
| <br>
+
|<br>
| <br>
+
|<br>
  +
|{{Al/E4}}
| <br>
 
  +
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29 R]
| <br>
 
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
  +
|[[Thermal Evaporation Recipes|A]]
| <br>
 
  +
|[[Thermal Evaporation Recipes|A]]
| <br>
 
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
 
| <br>
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ge
+
! bgcolor="#d0e7ff" align="center" |Cu
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Hf
+
! bgcolor="#d0e7ff" align="center" |Fe
  +
|{{Al/E1}}
| <br>
 
| <br>
+
|<br>
| <br>
+
|<br>
  +
|{{Al/E4}}
| <br>
 
  +
|[[Sputtering Recipes|R]]
| <br>
 
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
+
|<br>
| <br>
 
| <br>
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | HfO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |Ge
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E3}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E4}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | In
+
! bgcolor="#d0e7ff" align="center" |GeO<sub>2</sub>
  +
|
| <br>
 
  +
|{{Al/E2}}
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
  +
|
| <br>
 
| <br>
 
| <br>
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ir
+
! bgcolor="#d0e7ff" align="center" |Gd
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E4}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | ITO
+
! bgcolor="#d0e7ff" align="center" |Hf
  +
| bgcolor="#eeffff" |{{Al/E1}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Mo
+
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub>
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|{{rl|Atomic Layer Deposition Recipes|HfO2 deposition (ALD CHAMBER 3)}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Nb
+
! bgcolor="#d0e7ff" align="center" |In
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ni
+
! bgcolor="#d0e7ff" align="center" |Ir
  +
|{{Al/E1}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Pd
+
! bgcolor="#d0e7ff" align="center" |ITO
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |{{rl|E-Beam Evaporation Recipes|E-Beam 2 (Custom)|ITO deposition (E-Beam 2)}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]]
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Pt
+
! bgcolor="#d0e7ff" align="center" |MgF2
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ru
+
! bgcolor="#d0e7ff" align="center" |MgO
|
+
|
  +
|{{Al/E2}}
|
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Si
+
! bgcolor="#d0e7ff" align="center" |Mo
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|R]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | SiN
+
! bgcolor="#d0e7ff" align="center" |Nb
  +
|{{Al/E1}}
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|[[Sputtering Recipes|R]]
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
| {{rl|PECVD Recipes|SiN deposition (PECVD #1)}}
 
  +
|<br>
| {{rl|PECVD Recipes|SiN deposition (PECVD #2)}}
 
  +
|<br>
| {{rl|PECVD Recipes|SiN deposition (Unaxis VLR)}}
 
  +
|<br>
| {{rl|PECVD Recipes|SiO2 deposition (ALD)}}
 
| {{rl|PECVD Recipes|SiO2 deposition (IBD)}}
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | SiO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |Nd
  +
|
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (PECVD #1)}}
 
  +
|<br>
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (PECVD #2)}}
 
  +
|<br>
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (Unaxis VLR)}}
 
  +
|<br>
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (ALD)}}
 
| bgcolor="EEFFFF" | {{rl|PECVD Recipes|SiO2 deposition (IBD)}}
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | SiO<sub>x</sub>N<sub>y</sub>
+
! bgcolor="#d0e7ff" align="center" |Ni
  +
| bgcolor="#eeffff" |{{Al/E1}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |{{Al/E3}}
|
 
  +
| bgcolor="#eeffff" |{{Al/E4}}
|
 
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Sn
+
! bgcolor="#d0e7ff" align="center" |NiCr
  +
|{{Al/E1}}
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|{{Al/E4}}
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
  +
|
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | SrF<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |NiFe
  +
| bgcolor="#eeffff" |{{Al/E1}}
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |{{Al/E4}}
|
 
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ta
+
! bgcolor="#d0e7ff" align="center" |Pd
  +
|{{Al/E1}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|{{Al/E3}}
| bgcolor="EEFFFF" |
 
  +
|{{Al/E4}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|[[Thermal Evaporation Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|[[Thermal Evaporation Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ta<sub>2</sub>O<sub>5</sub>
+
! bgcolor="#d0e7ff" align="center" |Pt
  +
| bgcolor="#eeffff" |{{Al/E1}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |{{Al/E3}}
|
 
  +
| bgcolor="#eeffff" |{{Al/E4}}
|
 
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}}
|
 
  +
| bcolor="EEFFFF" |{{rl|Sputtering Recipes|Sputter 5 (AJA ATC 2200-V)}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|Pt deposition (ALD CHAMBER 1)}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Ti
+
! bgcolor="#d0e7ff" align="center" |Ru
  +
|{{Al/E1}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|{{Al/E4}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering Recipes#Ru Deposition .28Sputter 4.29|R]]
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|{{rl|Atomic Layer Deposition Recipes|Ru deposition (ALD CHAMBER 1)}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | TiN
+
! bgcolor="#d0e7ff" align="center" |Si
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |{{Al/E2}}
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|R]]
|
 
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]]
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=PECVD_Recipes#Amorphous-Si_deposition_.28PECVD_.232.29 R]
|
 
  +
| bgcolor="#eeffff" |
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
  +
| bgcolor="#eeffff" |<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | TiO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |SiN
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|{{rl|Sputtering Recipes|SiN deposition (Sputter 3)}}
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|[[Sputtering_Recipes#Si3N4_deposition_.28IBD.29|R]]
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|{{rl|PECVD Recipes|SiN deposition (PECVD #1)}}
| bgcolor="EEFFFF" |
 
  +
|{{rl|PECVD Recipes|SiN deposition (PECVD #2)}}
| bgcolor="EEFFFF" |
 
  +
|{{rl|PECVD Recipes|SiN 250C deposition (Unaxis VLR)}}
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
  +
|<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | V
+
! bgcolor="#d0e7ff" align="center" |SiN - Low Stress
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
  +
|{{rl|PECVD Recipes|Low-Stress SiN - LS-SiN (PECVD#1)}}
|
 
  +
|{{rl|PECVD Recipes|Low-Stress SiN deposition (PECVD #2)}}
|
 
  +
|{{rl|PECVD Recipes|SiN LS 250C Deposition (Unaxis VLR)}}
|
 
|
+
|
|
+
|
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | W
+
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E2}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|SiO2 deposition (Sputter 3)}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
  +
| bgcolor="#eeffff" |[[Sputtering_Recipes#SiO2_deposition_.28IBD.29|R]]
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 deposition (PECVD #1)}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 deposition (PECVD #2)}}
  +
| bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 LDR 250C Deposition (Unaxis VLR)}}
| bgcolor="EEFFFF" |
 
  +
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|SiO2 deposition (ALD CHAMBER 3)}}
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Zn
+
! bgcolor="#d0e7ff" align="center" |SiO<sub>x</sub>N<sub>y</sub>
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#SiOxNy_deposition_.28IBD.29 R]
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|[[PECVD_Recipes#PECVD_1_.28PlasmaTherm_790.29|R]]
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | ZnO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |Sn
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | Zr
+
! bgcolor="#d0e7ff" align="center" |SrF<sub>2</sub>
  +
|<br>
|
 
  +
|{{Al/E2}}
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
  +
|<br>
|
 
|
 
|
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | ZrO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |Ta
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{Al/E1}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ta deposition (Sputter 3)}}
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]]
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
+
| bgcolor="#eeffff" |<br>
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
 
|-
 
|-
! bgcolor="#D0E7FF" align="center" | '''Material'''
+
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
  +
|<br>
| bgcolor="#DAF1FF" | [[E-Beam 1 (Sharon)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[E-Beam 2 (Custom)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[E-Beam 3 (Temescal)]]
 
  +
|{{Al/E2}}
| bgcolor="#DAF1FF" | [[E-Beam 4 (CHA)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Sputter 1 (Custom)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Sputter 2 (SFI Endeavor)|Sputter 2<br>(SFI Endeavor)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Sputter 3 (ATC 2000-F)|Sputter 3<br>(ATC 2000-F)]]
 
  +
|[[Sputtering_Recipes#Ta2O5_deposition_.28IBD.29|R]]
| bgcolor="#DAF1FF" | [[Sputter 4 (ATC 2200-V)|Sputter 4<br>(ATC 2200-V)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Sputter 5 (Lesker AXXIS)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Thermal Evap 1]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Thermal Evap 2 (Solder)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[PECVD 1 (PlasmaTherm 790)|PECVD 1<br>(PlasmaTherm 790)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[PECVD 2 (Advanced Vacuum)|PECVD 2<br>(Advanced Vacuum)]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Unaxis VLR ICP-PECVD]]
 
  +
|<br>
| bgcolor="#DAF1FF" | [[Atomic Layer Deposition (Oxford FlexAL)|Atomic Layer Deposition (Tool)]]
 
  +
|-
| bgcolor="#DAF1FF" | [[Ion Beam Deposition (Veeco NEXUS)|Ion Beam<br>Deposition (Tool)]]
 
  +
! bgcolor="#d0e7ff" align="center" |Ti
| bgcolor="#DAF1FF" | [[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
 
  +
| bgcolor="#eeffff" |{{Al/E1}}
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |{{Al/E3}}
  +
| bgcolor="#eeffff" |{{Al/E4}}
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}}
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}}
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 5 (AJA ATC 2200-V)}}
  +
| bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]]
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |TiN
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29 R]
  +
|<br>
  +
|[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]]
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|{{rl|Atomic Layer Deposition Recipes|TiN deposition (ALD CHAMBER 3)}}
  +
|<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |TiW
  +
| bgcolor="#eeffff" |{{Al/E1}}
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|W-TiW Deposition (Sputter 4)}}
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |{{Al/E2}}
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}}
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |[[Sputtering_Recipes#TiO2_deposition_.28IBD.29|R]]
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|TiO2 deposition (ALD CHAMBER 3)}}
  +
| bgcolor="#eeffff" |<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |V
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|[[Sputtering Recipes|A]]
  +
|[[Sputtering Recipes|A]]
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |W
  +
| bgcolor="#eeffff" |{{Al/E1}}
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |[[Sputtering Recipes|A]]
  +
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|W deposition (Sputter 4)}}
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |Zn
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|[[Thermal Evaporation Recipes|A]]
  +
|[[Thermal Evaporation Recipes|A]]
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |ZnO
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZnO:Al deposition (ALD CHAMBER 1)}}
  +
| bgcolor="#eeffff" |<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |Zr
  +
|{{Al/E1}}
  +
|<br>
  +
|<br>
  +
|{{Al/E4}}
  +
|[[Sputtering Recipes|A]]
  +
|[[Sputtering Recipes|A]]
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|<br>
  +
|-
  +
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |<br>
  +
| bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZrO2 deposition (ALD CHAMBER 3)}}
  +
| bgcolor="#eeffff" |<br>
  +
|-
  +
! width="20" bgcolor="#d0e7ff" align="center" |'''Material'''
  +
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]]
  +
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]]
  +
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]]
  +
| width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]]
  +
| width="65" bgcolor="#daf1ff" |[[Sputtering Recipes#Sputter_3_.28ATC_2000-F.29|Sputter 3<br>(ATC 2000-F)]]
  +
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(ATC 2200-V)]]
  +
| width="65" bgcolor="#daf1ff" |[[Sputtering Recipes|Sputter 5 (ATC 2200-V)]]
  +
| width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]]
  +
| width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]]
  +
| width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]]
  +
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]]
  +
| width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]]
  +
| width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]]
  +
| width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAl)]]
  +
| width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]]
 
|}
 
|}
  +
  +
[[Category:Processing]]

Latest revision as of 15:44, 7 July 2022

Process Control Data

See linked page for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.

Deposition Tools/Materials Table

  • R: Recipe is available. Clicking this link will take you to the recipe.
  • A: Material is available for use, but no recipes are provided.
Vacuum Deposition Recipes

E-Beam Evaporation Sputtering Thermal Evaporation Plasma Enhanced Chemical
Vapor Deposition (PECVD)
Atomic Layer Deposition Molecular Vapor Deposition
Material E-Beam 1 (Sharon) E-Beam 2 (Custom) E-Beam 3 (Temescal) E-Beam 4 (CHA) Sputter 3
(AJA ATC 2000-F)
Sputter 4
(AJA ATC 2200-V)
Sputter 5 (AJA ATC 2200-V) Ion Beam
Deposition (Veeco Nexus)
Thermal
Evap 1
Thermal Evap 2 (Solder) PECVD 1
(PlasmaTherm 790)
PECVD 2
(Advanced Vacuum)
Unaxis VLR ICP-PECVD Atomic Layer Deposition (Oxford FlexAL) Molecular Vapor Deposition (Tool)
Ag A
A A A A








Al A
A A A R

A
A A




Al2O3 A A

A R
R




R
AlN



A A
A




R
Au A
A A A R

A A




B














C R
CeO2
R












Co A

A R









Cr A

A R


A A




Cu A


R A








Fe A

A R









Ge A
A A A A








GeO2 A
Gd A

A










Hf A













HfO2



A A






R
In








A




Ir A













ITO
R

A A
A






MgF2 A A
MgO A
Mo A


R A








Nb A



R








Nd



A








Ni A
A A R


A A




NiCr A A
NiFe A A A
Pd A
A A



A A




Pt A
A A A R R





R
Ru A

A
R






R
Si
A

R A

A



R

SiN



R A
R

R R R

SiN - Low Stress R R R
SiO2 A A

R A A R

R R R R
SiOxNy






R

R



Sn








A




SrF2
A












Ta A


R A

A







Ta2O5


A


R






Ti A
A A R R R
A







TiN




R
A




R
TiW A


A R








TiO2
A

A R
R




R
V



A A








W A


A R








Zn







A A




ZnO












R
Zr A

A A A








ZrO2












R
Material E-Beam 1 (Sharon) E-Beam 2 (Custom) E-Beam 3 (Temescal) E-Beam 4 (CHA) Sputter 3
(ATC 2000-F)
Sputter 4
(ATC 2200-V)
Sputter 5 (ATC 2200-V) Ion Beam
Deposition (Veeco Nexus)
Thermal
Evap 1
Thermal Evap 2 (Solder) PECVD 1
(PlasmaTherm 790)
PECVD 2
(Advanced Vacuum)
Unaxis VLR ICP-PECVD Atomic Layer Deposition (Oxford FlexAl) Molecular Vapor Deposition (Tool)