Difference between revisions of "Test Data of etching SiO2 with CHF3/CF4/O2 (using this recipe only for Fluorine etch of the underneath layer)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(add data)
Line 13: Line 13:
 
|0.74
 
|0.74
 
|77.9
 
|77.9
  +
|-
  +
|1/28/19
  +
|I21902
  +
|92.1
  +
|0.77
  +
|
 
|}
 
|}
 
https://www.nanotech.ucsb.edu/wiki/images/f/f1/SiO2_Etch_using_ICP2_with_O2.pdf
 
https://www.nanotech.ucsb.edu/wiki/images/f/f1/SiO2_Etch_using_ICP2_with_O2.pdf

Revision as of 10:37, 29 January 2019

ICP#2: 0.5Pa, 50/500W, CHF3/CF4/O2=35/5/10sccm, time=210 sec
Date Sample# Etch Rate (nm/min) Etch Selectivity (SiO2/PR) Averaged Sidewall Angle (o)
10/5/2018 SiO2#01 95.2 0.74 77.9
1/28/19 I21902 92.1 0.77

https://www.nanotech.ucsb.edu/wiki/images/f/f1/SiO2_Etch_using_ICP2_with_O2.pdf