| colspan="6" |1/13 rate is low by ~20%, so chamber was wet-cleaned on 1/21/2020.  Data below for 1/23 shows rate returned to "normal".
 
|-
 
|-
 
|1/23/2020
 
|1/23/2020

Revision as of 18:00, 23 January 2020

ICP#1: 0.5Pa, 50/900W, CHF3/CF4=10/30 sccm, time=210 sec
Date Sample# Etch Rate (nm/min) Etch Selectivity (SiO2/PR) Averaged Sidewall Angle (o) SEM Images
1/28/2019 I11901 110 1.35 [1]
5/29/2019 I11903 105 1.41 [2]
1/13/2020 I12001 78.0 1.06 [3]
1/13 rate is low by ~20%, so chamber was wet-cleaned on 1/21/2020. Data below for 1/23 shows rate returned to "normal".
1/23/2020 I12002 109 1.16 [4]