Difference between revisions of "Template:Recipe"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(1st attempt, using definition list)
 
(added headings, Charact section)
Line 1: Line 1:
  +
==Recipe==
 
<includeonly>[[category:Recipes]]</includeonly>
 
<includeonly>[[category:Recipes]]</includeonly>
 
;Recipe Name
 
;Recipe Name
Line 20: Line 21:
 
: This recipe usually doesn't work.
 
: This recipe usually doesn't work.
 
: Film will etch in HF
 
: Film will etch in HF
  +
  +
-----
  +
  +
==Characterization==
  +
[[File:Al-thickness-variation-with-rate.jpg]]

Revision as of 14:43, 3 August 2017

Recipe

Recipe Name
SiOVert_MadeUp
Description
This recipe is made up, and deposits glass with lots of holes in it.
Recipe Parameters
Ar = 20 sccm
O2 = 10 sccm
Pressure = 50 mT
RF = 200 W
Temperature = 200°C
Dep Rate
200 nm/min or 12,000 nm/sec
Notes
Make sure sample is inside out before loading into tool.
This recipe usually doesn't work.
Film will etch in HF

Characterization

Al-thickness-variation-with-rate.jpg