Search results
Jump to navigation
Jump to search
- |type = Vacuum Deposition |description = Molecular Vapor Deposition System1 KB (182 words) - 10:34, 30 August 2022
- ...50C in PECVD#1. Instructions bellow explain how to run process (seasoning, deposition, cleaning). === Standard Si3N4 (Silicon-Nitride) Deposition ===2 KB (270 words) - 13:16, 10 December 2020
- ===PECVD1 deposition - 300nm SiN film @250°C=== ...easoning, deposition, and cleaning). You can '''ONLY''' change the time in recipes.2 KB (325 words) - 16:38, 30 March 2020
- ...C. Instructions bellow explain how to run each of the recipes ( seasoning, deposition, cleaning) === Standard Oxide Deposition ===3 KB (416 words) - 16:54, 22 April 2020
- |type = Vacuum Deposition *'''Size''': The sample electrode has a 270mm diameter useable area, allowing for multiple 4” wafer depositions in a single run.2 KB (284 words) - 10:30, 30 August 2022
- === '''Unaxis deposition - 300nm SiO2 LDR film @250°C''' === * for seasoning (regular Si wafer ~500nm thick)4 KB (711 words) - 13:32, 30 March 2020
- |type = Vacuum Deposition ...p to ~ 5" diameter can be placed into this system for evaporation. Typical deposition rates are several Angstroms/second.2 KB (297 words) - 11:31, 25 August 2023
- * Maximum 0.5µm of deposition prior to chamber cleaning, in order to maintain low particle counts. ...Unaxis Recipes''' page]] for thin-film properties of each of the following recipes.5 KB (801 words) - 21:29, 12 August 2020
- The wafers for process calibration are ordered from SVM (<nowiki>https://www.svmi.com/</no === Scan Before Deposition ===3 KB (515 words) - 13:41, 20 April 2020
- |type = Vacuum Deposition |description = PECVD Plasma Therm 790 For Oxides And Nitrides3 KB (387 words) - 22:15, 23 August 2021
- |type = Vacuum Deposition |description = PECVD Plasma Therm 790 For Oxides And Nitrides3 KB (388 words) - 10:30, 30 August 2022
- {{recipes|Vacuum Deposition}} ==SiO<sub>2</sub> deposition (PECVD #1)==14 KB (2,130 words) - 10:28, 20 December 2023
- |type = Vacuum Deposition ...ith very narrow source shutter gaps. Uniformity better than 2% is achieved for various sample heights.3 KB (507 words) - 10:37, 30 August 2022
- |type = Vacuum Deposition |description = Ion Beam Deposition Tool4 KB (522 words) - 11:04, 11 January 2024
- <big>Back to [[Vacuum Deposition Recipes]]</big> ==SiO<sub>2</sub> deposition (PECVD #1)==36 KB (5,386 words) - 09:31, 14 December 2021
- |type = Vacuum Deposition ...variety of materials. The system is recipe driven and computer controlled for reproducible results.3 KB (413 words) - 15:50, 16 September 2022
- <big>Back to [[Vacuum Deposition Recipes]]</big> ==SiO<sub>2</sub> deposition (PECVD #1)==17 KB (2,624 words) - 00:07, 16 December 2021
- {{recipes|Vacuum Deposition}} =[[Atomic Layer Deposition (Oxford FlexAL)]]=7 KB (1,104 words) - 10:27, 15 June 2023
- From [[PECVD Recipes]] page: {{recipes|Vacuum Deposition}}31 KB (4,516 words) - 00:18, 16 December 2021
- |type = Vacuum Deposition ...rces. The sources are contained in tiltable sputter gun modules that allow for maintaining uniformity control at various sample heights. Cross contaminati3 KB (479 words) - 10:36, 30 August 2022
- .../sub>N<sub>4</sub> films. The systems are both equipped with O<sub>2</sub> for organic removal / surface activation. One system also has CF<sub>4</sub>/O<sub>2</sub> 88% / 12% for etching Si<sub>3</sub>N<sub>4</sub>. These systems are operated manually an2 KB (347 words) - 13:06, 11 November 2022
- ''The following are positions we are currently hiring for:'' *This position is for current UCSB Undergraduate students. Ideally in a technical field, optional4 KB (607 words) - 11:48, 24 April 2024
- {{recipes|Vacuum Deposition}} {{rl|Atomic Layer Deposition Recipes|Pt deposition (ALD)}}16 KB (2,290 words) - 21:36, 21 September 2023
- ==Table of Wet Etching Recipes== [[Wet Etching Recipes#Organic%20removal|Piranha Solution]]10 KB (1,405 words) - 10:34, 1 April 2024
- The ASML 5500 stepper is a 248nm (KrF) DUV stepper for imaging dense features down to below 200nm and isolated line structures dow ...ligned patterns from multiple masks/reticles in a single session, allowing for process optimization of large vs. small features in a single lithography.9 KB (1,400 words) - 13:08, 3 May 2024
- {{recipes|Dry Etching}} ...a wafer from falling into the machine after the etch, you can [[Packaging Recipes#Wafer Bonder .28Logitech WBS7.29|mount to a carrier wafer using wax]].28 KB (4,356 words) - 12:49, 7 May 2024
- Below is the procedure we use for calibrating particle counts on various machines, primarily depositions. The wafers for process calibration are ordered from a wafer supplier that sells high grade33 KB (5,424 words) - 17:05, 4 January 2024
- ...e entity (universtiy/company etc.) to see the process and paperwork needed for your staff to access our lab in-person. The [https://www.nanotech.ucsb.edu ====Can staff perform fabrication for us?====25 KB (4,202 words) - 20:37, 13 May 2024