User contributions
Jump to navigation
Jump to search
- 16:58, 8 November 2012 diff hist 0 N File:AZnLOF2020-Negative-Resist-Datasheet.pdf current
- 16:58, 8 November 2012 diff hist 0 N File:AZnLOF5510-Negative-Resist-Datasheet.pdf current
- 16:57, 8 November 2012 diff hist 0 N File:AZ5214-Negative-Resist-Datasheet.pdf current
- 16:56, 8 November 2012 diff hist +331 Lithography Recipes →Chemical Datasheets
- 16:55, 8 November 2012 diff hist 0 N File:SPR955-Positive-Resist-Datasheet.pdf current
- 16:55, 8 November 2012 diff hist 0 N File:SPR950-Positive-Resist-Datasheet.pdf current
- 16:54, 8 November 2012 diff hist 0 N File:SPR220-Positive-Resist-Datasheet.pdf current
- 16:54, 8 November 2012 diff hist 0 N File:OCG825-Positive-Resist-Datasheet.pdf current
- 16:52, 8 November 2012 diff hist +91 Lithography Recipes
- 16:51, 8 November 2012 diff hist 0 N File:AXP4000pb-Datasheet.pdf
- 15:14, 8 November 2012 diff hist -20 Contact Alignment Recipes →Contact Aligner (SUSS MA-6)
- 15:14, 8 November 2012 diff hist +18 Contact Alignment Recipes
- 15:12, 8 November 2012 diff hist +4 Contact Alignment Recipes →Negative Resist (MA-6)
- 15:10, 8 November 2012 diff hist +6 Contact Alignment Recipes →Positive Resist (MA-6)
- 13:34, 8 November 2012 diff hist +375 Lithography Recipes →Recipes
- 13:32, 8 November 2012 diff hist +65 Contact Alignment Recipes →Contact Aligner (SUSS MA-6)
- 13:32, 8 November 2012 diff hist +80 N Category:To Do Created page with "These are pages that I (zwarburg) need to finish something on." current
- 13:31, 8 November 2012 diff hist +73 Contact Alignment Recipes →Contact Aligner (SUSS MA-6)
- 13:30, 8 November 2012 diff hist 0 Template:Todo current
- 13:30, 8 November 2012 diff hist 0 Template:Todo
- 13:30, 8 November 2012 diff hist 0 Template:Todo
- 13:30, 8 November 2012 diff hist -3 Template:Todo
- 13:29, 8 November 2012 diff hist -14 Template:Todo
- 13:29, 8 November 2012 diff hist +225 N Template:Todo/doc Created page with "This template reminds me (zwarburg) of things that I still need to do on a page. It takes one argument which is the note. {{tlx|todo|This is an example}} prod…" current
- 13:29, 8 November 2012 diff hist +484 N Template:Todo Created page with "<includeonly>{| align=center style="border: 1px solid #000000; background-color:transparent; padding:1px;" |- |bgcolor={{Color/Attention}} style="color:#000000; margin:10px; bord…"
- 13:27, 8 November 2012 diff hist -2 Contact Alignment Recipes →Contact Aligner (SUSS MA-6)
- 13:24, 8 November 2012 diff hist +3,028 Contact Alignment Recipes
- 13:24, 8 November 2012 diff hist -41 Contact Alignment Recipes
- 13:23, 8 November 2012 diff hist +36 Lithography Recipes
- 13:22, 8 November 2012 diff hist +382 Lithography Recipes →Lift-Off Techniques
- 13:21, 8 November 2012 diff hist -63 Contact Alignment Recipes →Negative Resist (MJB-3)
- 13:21, 8 November 2012 diff hist 0 N File:AZnLOF2020contactrecipe.pdf current
- 13:14, 8 November 2012 diff hist +1,065 Contact Alignment Recipes →Positive Resist (MJB-3)
- 13:14, 8 November 2012 diff hist +130 Contact Alignment Recipes →Suss Aligners (SUSS MJB-3)
- 13:11, 8 November 2012 diff hist 0 N File:SPR220-7contactrecipe.pdf current
- 13:11, 8 November 2012 diff hist +823 Contact Alignment Recipes →Suss Aligners (SUSS MJB-3)
- 13:09, 8 November 2012 diff hist 0 N File:SPR220-3contactrecipe.pdf current
- 12:55, 8 November 2012 diff hist +2,035 Contact Alignment Recipes
- 12:49, 8 November 2012 diff hist -9 Template:LithRecipe Table
- 12:48, 8 November 2012 diff hist +182 Lithography Recipes
- 12:36, 8 November 2012 diff hist 0 N File:Bi-LayerContactprocesswithPMGI.pdf current
- 12:35, 8 November 2012 diff hist 0 N File:Liftoff-Techniques.pdf current
- 12:47, 4 October 2012 diff hist -6 PECVD Recipes →SiN (100% SiH4 )
- 09:05, 1 October 2012 diff hist +42 Vacuum Deposition Recipes
- 09:03, 1 October 2012 diff hist +80 Sputtering Recipes →Ion Beam Deposition (Veeco NEXUS)
- 09:03, 1 October 2012 diff hist 0 N File:IBD-TiO2-Recipe.pdf current
- 08:57, 1 October 2012 diff hist 0 N File:PECVD2-SiN-Recipe-100SiH4-100C-Medium-Stress.pdf current
- 08:57, 1 October 2012 diff hist 0 N File:PECVD2-SiN-Recipe-100SiH4-100C-Low-Stress.pdf current
- 08:57, 1 October 2012 diff hist +285 PECVD Recipes →SiN deposition (Unaxis VLR)
- 09:38, 18 September 2012 diff hist +29 Dry Etching Recipes
- 09:37, 18 September 2012 diff hist 0 Vacuum Deposition Recipes
- 09:35, 18 September 2012 diff hist +51 N Template:Recipe Table Explination/doc moved Template:Recipe Table Explination/doc to Template:Recipe Table Explanation/doc current
- 09:35, 18 September 2012 diff hist 0 m Template:Recipe Table Explanation/doc moved Template:Recipe Table Explination/doc to Template:Recipe Table Explanation/doc current
- 09:35, 18 September 2012 diff hist 0 m Template:Recipe Table Explanation moved Template:Recipe Table Explination to Template:Recipe Table Explanation
- 09:07, 18 September 2012 diff hist -13 XeF2 Etch (Xetch) →Documentation
- 08:59, 18 September 2012 diff hist +3 XeF2 Etch (Xetch) →Documentation
- 08:58, 18 September 2012 diff hist +31 XeF2 Etch (Xetch) →Documentation
- 08:58, 18 September 2012 diff hist 0 N File:XeF2-Results.pdf current
- 08:57, 18 September 2012 diff hist +36 XeF2 Etch (Xetch) →Documentation
- 07:57, 10 September 2012 diff hist 0 N File:ICP1-Gas-Change-CHF3-AR.pdf current
- 07:57, 10 September 2012 diff hist +86 ICP Etch 1 (Panasonic E646V)
- 11:27, 7 September 2012 diff hist -17 Vacuum Deposition Recipes
- 11:27, 7 September 2012 diff hist +212 N Template:Recipe Table Explanation Created page with "<big> *'''R''' = Recipe is available. Clicking this link will take you to the recipe. *'''A''' = Material is available for use, but no recipes are provided.</big><noinclude>{{Doc…"
- 11:24, 7 September 2012 diff hist +60 N Template:Recipe Table Explanation/doc Created page with "This template provides an explanation for the recipe tables."
- 11:21, 7 September 2012 diff hist +39 Vacuum Deposition Recipes
- 11:21, 7 September 2012 diff hist +1,064 Vacuum Deposition Recipes
- 11:17, 7 September 2012 diff hist +143 Vacuum Deposition Recipes
- 11:11, 7 September 2012 diff hist +61 N Template:Al/E4 Created page with "{{Al|E-Beam Evaporation Recipes|Materials Table (E-Beam #4)}}" current
- 11:11, 7 September 2012 diff hist +61 N Template:Al/E3 Created page with "{{Al|E-Beam Evaporation Recipes|Materials Table (E-Beam #3)}}" current
- 11:11, 7 September 2012 diff hist +52 Template:Al/E2 current
- 11:11, 7 September 2012 diff hist +9 N Template:Al/E2 Created page with "{{Al/E1}}"
- 11:11, 7 September 2012 diff hist +50 Vacuum Deposition Recipes
- 11:08, 7 September 2012 diff hist +195 Template:Al/doc current
- 11:05, 7 September 2012 diff hist -1 Template:Al/E1 current
- 11:05, 7 September 2012 diff hist +62 N Template:Al/E1 Created page with " {{Al|E-Beam Evaporation Recipes|Materials Table (E-Beam #1)}}"
- 11:04, 7 September 2012 diff hist +131 N Template:Al/doc Created page with "This template (al = Avaliable Link) takes 2 arguments. *the first argument is the page name *the second argument is the subheading"
- 11:03, 7 September 2012 diff hist +102 N Template:Al Created page with "<includeonly>[[{{{1}}}#{{{2}}}{{!}}A]]</includeonly><noinclude>Category:Templates{{Documentation}}" current
- 11:02, 7 September 2012 diff hist -10 E-Beam Evaporation Recipes →Materials Table (E-Beam #2)
- 11:02, 7 September 2012 diff hist +2,784 E-Beam Evaporation Recipes
- 11:02, 7 September 2012 diff hist -1,243 E-Beam 4 (CHA) →Materials Table
- 11:02, 7 September 2012 diff hist -1,249 E-Beam 3 (Temescal) →Materials Table
- 11:01, 7 September 2012 diff hist +1,171 E-Beam Evaporation Recipes →E-Beam 2 (Custom)
- 11:00, 7 September 2012 diff hist -1,014 E-Beam 2 (Custom) →Materials Table
- 11:00, 7 September 2012 diff hist -6 E-Beam 1 (Sharon) →Materials Table
- 11:00, 7 September 2012 diff hist -2,430 E-Beam 1 (Sharon) →Materials Table
- 10:59, 7 September 2012 diff hist +12 E-Beam Evaporation Recipes
- 10:58, 7 September 2012 diff hist +2,568 E-Beam Evaporation Recipes →E-Beam 1 (Sharon)
- 10:17, 7 September 2012 diff hist 0 N File:IBD-SiN-recipe.pdf current
- 10:17, 7 September 2012 diff hist +44 Sputtering Recipes →SiN deposition (IBD)
- 10:09, 7 September 2012 diff hist -5 Template:Rl current
- 10:07, 7 September 2012 diff hist +39 Vacuum Deposition Recipes
- 10:06, 7 September 2012 diff hist +5 Template:Rl
- 08:36, 7 September 2012 diff hist -27 Vacuum Deposition Recipes
- 08:35, 7 September 2012 diff hist +339 Sputtering Recipes
- 08:04, 7 September 2012 diff hist +613 Vacuum Deposition Recipes
- 06:53, 7 September 2012 diff hist +104 Vacuum Deposition Recipes
- 06:52, 7 September 2012 diff hist 0 N File:IBD-Ta2O5-Recipe.pdf current
- 06:50, 7 September 2012 diff hist 0 N File:IBD-SiO2-Recipe.pdf current
- 11:35, 6 September 2012 diff hist +30 Atomic Layer Deposition Recipes
- 11:35, 6 September 2012 diff hist +132 Vacuum Deposition Recipes