User contributions
Jump to navigation
Jump to search
- 08:21, 11 September 2021 diff hist +53 m ICP Etch 1 (Panasonic E646V) Updated system description Tag: Visual edit: Switched
- 08:15, 11 September 2021 diff hist -88 Stepper 2 (AutoStep 200) Removed link to deleted shutdown startup page Tag: Visual edit
- 11:38, 10 September 2021 diff hist +4 ICP Etch 1 (Panasonic E646V) Tag: Visual edit
- 11:37, 10 September 2021 diff hist +240 ICP Etch 1 (Panasonic E646V) Updated gas changes SOPs, added Rules link Tag: Visual edit
- 11:33, 10 September 2021 diff hist +198 ICP Etch 1 (Panasonic E646V) Updated Gas Change SOP Tag: Visual edit
- 11:28, 10 September 2021 diff hist 0 N File:ICP -1 Rules & Important Notes.pdf current
- 11:27, 10 September 2021 diff hist 0 N File:ICP -1 Gas Change N2-He-N2.pdf
- 11:27, 10 September 2021 diff hist 0 N File:ICP -1 Gas Change CHF3-Ar-CHF3.pdf current
- 11:26, 10 September 2021 diff hist 0 N File:ICP -1 Gas Change CF4-SF6-CF4.pdf
- 11:19, 10 September 2021 diff hist -14 ICP Etch 1 (Panasonic E646V) Updated tool About section Tag: Visual edit
- 12:40, 9 September 2021 diff hist -23 Dicing Saw (ADT) Updated SOP Rev Tag: Visual edit
- 12:39, 9 September 2021 diff hist 0 N File:ADT SOP Rev D.pdf current
- 10:25, 3 September 2021 diff hist -2 m E-Beam 2 (Custom) Changed tool owner
- 14:08, 23 August 2021 diff hist 0 File:ADT Dicing Saw SOP Rev C.pdf Sawyer l uploaded a new version of File:ADT Dicing Saw SOP Rev C.pdf current
- 09:01, 20 August 2021 diff hist +4 Dicing Saw (ADT) SOP Rev Tag: Visual edit
- 09:00, 20 August 2021 diff hist 0 N File:ADT Dicing Saw SOP Rev C.pdf
- 14:08, 11 August 2021 diff hist -6 Contact Aligner (SUSS MA-6) →Documentation Tag: Visual edit
- 14:08, 11 August 2021 diff hist 0 File:MA-6 Exp Mode Visual Aid.pdf Sawyer l uploaded a new version of File:MA-6 Exp Mode Visual Aid.pdf current
- 14:08, 11 August 2021 diff hist -3 Contact Aligner (SUSS MA-6) →Documentation Tag: Visual edit
- 14:07, 11 August 2021 diff hist +100 Contact Aligner (SUSS MA-6) →Documentation: Added BA6 SOP Tag: Visual edit
- 14:05, 11 August 2021 diff hist 0 N File:BA6 SOP Rev A.pdf current
- 14:19, 10 August 2021 diff hist +153 Dicing Saw (ADT) →Operating Procedures: Add link to updated SOP Tag: Visual edit
- 14:17, 10 August 2021 diff hist 0 N File:ADT Dicing Saw SOP Rev B.pdf current
- 09:08, 20 July 2021 diff hist -3 Dicing Saw (ADT) Contact info Tag: Visual edit
- 08:34, 20 July 2021 diff hist +125 Stepper 2 (AutoStep 200) →Staff Procedures: Added restart SOP pdf link Tag: Visual edit
- 08:33, 20 July 2021 diff hist 0 N File:Autostep 200 Restart SOP June 2021.pdf current
- 13:19, 19 July 2021 diff hist +124 Maskless Aligner (Heidelberg MLA150) →Design Tools/Info: Added substrate template rules visual aid Tag: Visual edit
- 13:18, 19 July 2021 diff hist 0 N File:MLA150 Substrate Template Rules.pdf current
- 10:24, 13 July 2021 diff hist -31 Contact Aligner (SUSS MA-6) Updated SOP with BSA steps, removed old BSA steps Tag: Visual edit
- 10:22, 13 July 2021 diff hist 0 N File:MA-6 SOP Rev D.pdf
- 13:10, 26 May 2021 diff hist 0 Maskless Aligner (Heidelberg MLA150) Updated SOP Tag: Visual edit
- 13:09, 26 May 2021 diff hist 0 N File:MLA150 SOP Rev I (LS).pdf current
- 10:31, 19 April 2021 diff hist +72 Film Stress (Tencor Flexus) →Documentation: Added SOP link Tag: Visual edit
- 10:31, 19 April 2021 diff hist 0 N File:Tencor FLX SOP Rev B.pdf current
- 10:29, 19 April 2021 diff hist +66 Film Stress (Tencor Flexus) Added Documentation Section Tag: Visual edit
- 10:06, 19 April 2021 diff hist +68 Film Stress (Tencor Flexus) →Equipment Specifications Tag: Visual edit
- 09:33, 19 April 2021 diff hist +381 Film Stress (Tencor Flexus) Updating Equipment Specifications Tag: Visual edit
- 08:32, 16 March 2021 diff hist 0 Maskless Aligner (Heidelberg MLA150) Updated SOP Tag: Visual edit
- 08:31, 16 March 2021 diff hist 0 N File:MLA150 SOP Rev H (LS).pdf current
- 11:28, 15 March 2021 diff hist 0 RIE 3 (MRC) Updated SOP Tag: Visual edit
- 11:28, 15 March 2021 diff hist 0 N File:RIE 3 SOP Rev D.pdf current
- 10:30, 12 February 2021 diff hist +21 Maskless Aligner (Heidelberg MLA150) Update SOP link Tag: Visual edit
- 10:29, 12 February 2021 diff hist 0 N File:MLA150 SOP Rev G (LS).pdf current
- 12:19, 30 November 2020 diff hist -18 Contact Aligner (SUSS MA-6) Intensity info for CH2 updated, SOP updated Tag: Visual edit
- 12:18, 30 November 2020 diff hist 0 N File:MA-6 SOP Rev C.pdf current
- 08:13, 29 October 2020 diff hist +12 Contact Aligner (SUSS MA-6) New SOP rev. Change Ch2 intensity info Tag: Visual edit
- 09:23, 2 October 2020 diff hist -3 Plasma Clean (YES EcoClean) updated SOP link Tag: Visual edit
- 09:22, 2 October 2020 diff hist 0 N File:YES SOP Rev C.pdf current
- 09:01, 23 September 2020 diff hist +3 m Dicing Saw (ADT)
- 11:57, 16 September 2020 diff hist -68 Suss Aligners (SUSS MJB-3) Changed wording to reflect the downsizing to 2 aligners. Tag: Visual edit
- 10:46, 13 September 2020 diff hist 0 RIE 2 (MRC) SOP rev Tag: Visual edit
- 10:45, 13 September 2020 diff hist 0 N File:RIE 2 SOP Rev B.pdf current
- 07:39, 20 August 2020 diff hist -42 Contact Alignment Recipes Updated MA-6 neg resist flood expose info. Tag: Visual edit
- 11:56, 7 August 2020 diff hist +6 IR Aligner (SUSS MJB-3 IR) SOP rev current Tag: Visual edit
- 11:55, 7 August 2020 diff hist 0 N File:MJB 3 IR Camera SOP Rev B.pdf
- 11:51, 7 August 2020 diff hist 0 File:MJB 3 IR Camera SOP.pdf Sawyer l uploaded a new version of File:MJB 3 IR Camera SOP.pdf current
- 09:55, 1 August 2020 diff hist 0 RIE 3 (MRC) updated SOP link Tag: Visual edit
- 09:55, 1 August 2020 diff hist 0 N File:RIE 3 SOP Rev C.pdf current
- 10:02, 16 July 2020 diff hist -749 IR Aligner (SUSS MJB-3 IR) System information Tag: Visual edit
- 09:54, 16 July 2020 diff hist +111 IR Aligner (SUSS MJB-3 IR) added additional documentation Tag: Visual edit
- 09:53, 16 July 2020 diff hist 0 N File:MJB 3 IR Camera SOP.pdf
- 09:52, 16 July 2020 diff hist +129 IR Aligner (SUSS MJB-3 IR) added additional documentation Tag: Visual edit
- 09:51, 16 July 2020 diff hist 0 N File:MJB 3 IR Alignment Mode Conversion.pdf current
- 17:34, 5 March 2020 diff hist 0 RIE 3 (MRC) updated SOP link Tag: Visual edit
- 17:33, 5 March 2020 diff hist 0 N File:RIE 3 SOP Rev B.pdf current
- 12:20, 26 February 2020 diff hist +1 E-Beam 2 (Custom)
- 12:18, 26 February 2020 diff hist -153 Plasma Clean (YES EcoClean)
- 12:14, 26 February 2020 diff hist +47 Plasma Clean (YES EcoClean)
- 17:45, 24 February 2020 diff hist 0 N File:IMG 5385.JPG current
- 09:11, 7 January 2020 diff hist +4 E-Beam 2 (Custom) Updated SOP link to new rev Tag: Visual edit
- 09:01, 7 January 2020 diff hist 0 N File:EB2 SOP Rev B.pdf current
- 10:18, 5 November 2019 diff hist +6 Plasma Clean (YES EcoClean) updated SOP linked Tag: Visual edit
- 10:17, 5 November 2019 diff hist 0 N File:YES SOP Rev B.pdf current
- 11:23, 24 October 2019 diff hist -203 IR Aligner (SUSS MJB-3 IR) →About: correct about and spec section Tag: Visual edit
- 10:18, 17 October 2019 diff hist +3 Plasma Clean (YES EcoClean) Tag: Visual edit
- 10:17, 17 October 2019 diff hist +49 Plasma Clean (YES EcoClean) updated contact info Tag: Visual edit
- 10:15, 17 October 2019 diff hist -13 Plasma Clean (YES EcoClean)
- 10:15, 17 October 2019 diff hist +13 Plasma Clean (YES EcoClean)
- 14:16, 9 October 2019 diff hist +90 Plasma Activation (EVG 810) Tag: Visual edit
- 14:15, 9 October 2019 diff hist 0 N File:EVG Plasma Activation Recipe Copying.pdf current
- 14:15, 9 October 2019 diff hist +21 Plasma Activation (EVG 810) updated SOP & added recipe editing SOP Tag: Visual edit
- 14:13, 9 October 2019 diff hist 0 N File:EVG Plasma Activation SOP Rev B.pdf current
- 07:59, 25 September 2019 diff hist +58 Plasma Clean (YES EcoClean) Added doc section and linked SOP Tag: Visual edit
- 07:58, 25 September 2019 diff hist 0 N File:YES SOP.pdf current
- 07:57, 25 September 2019 diff hist +79 Plasma Clean (YES EcoClean) Tag: Visual edit: Switched
- 14:11, 24 September 2019 diff hist +22 Contact Aligner (SUSS MA-6) →Detailed Specifications Tag: Visual edit
- 11:27, 20 September 2019 diff hist +120 E-Beam 2 (Custom) Doc section added, SOP linked Tag: Visual edit
- 11:25, 20 September 2019 diff hist 0 N File:EB2 SOP.pdf current
- 11:39, 17 September 2019 diff hist +430 Contact Aligner (SUSS MA-6) →Detailed Specifications: updated system specs Tag: Visual edit
- 14:41, 16 September 2019 diff hist +127 IR Aligner (SUSS MJB-3 IR) add SOP link, doc section Tag: Visual edit
- 14:39, 16 September 2019 diff hist -75 Suss Aligners (SUSS MJB-3) →Documentation Tag: Visual edit
- 14:39, 16 September 2019 diff hist -1 Suss Aligners (SUSS MJB-3) added SOP link Tag: Visual edit
- 14:37, 16 September 2019 diff hist 0 N File:MJB 3 SOP.pdf current
- 10:55, 12 September 2019 diff hist +277 Oxygen Plasma System Recipes →Plasma Activation (EVG 810): added recipe details Tag: Visual edit
- 16:08, 11 September 2019 diff hist +82 Contact Aligner (SUSS MA-6) visual aid link Tag: Visual edit
- 16:08, 11 September 2019 diff hist 0 N File:MA-6 Exp Mode Visual Aid.pdf
- 16:07, 11 September 2019 diff hist +32 Contact Aligner (SUSS MA-6) Tag: Visual edit
- 16:07, 11 September 2019 diff hist -26 Contact Aligner (SUSS MA-6) SOP linked Tag: Visual edit
- 16:05, 11 September 2019 diff hist 0 N File:MA-6 SOP Rev B.pdf current
- 16:03, 11 September 2019 diff hist +55 Contact Aligner (SUSS MA-6) verbiage and spec changes Tag: Visual edit