User contributions
Jump to navigation
Jump to search
- 14:40, 28 July 2016 diff hist +52 PECVD Recipes →Amorphous-Si deposition (PECVD #2)
- 14:39, 28 July 2016 diff hist 0 N File:ASi deposition and film stress using AV dep tool.pdf current
- 14:38, 28 July 2016 diff hist +48 PECVD Recipes →Amorphous-Si deposition (PECVD #2)
- 14:20, 28 July 2016 diff hist +3 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:19, 28 July 2016 diff hist +1 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:19, 28 July 2016 diff hist +4 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:19, 28 July 2016 diff hist +14 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:16, 28 July 2016 diff hist +23 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:15, 28 July 2016 diff hist +65 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:14, 28 July 2016 diff hist +43 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:13, 28 July 2016 diff hist -111 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:12, 28 July 2016 diff hist +65 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:11, 28 July 2016 diff hist 0 N File:Amorphous Silicon Film Deposition using 12.5W bias on SiO2-Si.pdf current
- 14:10, 28 July 2016 diff hist +45 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 11:13, 28 July 2016 diff hist 0 Sputtering Recipes
- 11:11, 28 July 2016 diff hist +58 Sputtering Recipes →ITO deposition (E-Beam-2)
- 11:08, 28 July 2016 diff hist -57 Sputtering Recipes →ITO deposition (E-Beam-2)
- 11:07, 28 July 2016 diff hist +57 Sputtering Recipes →ITO deposition (E-Beam-2)
- 11:06, 28 July 2016 diff hist 0 N File:Rapid Thermal Annealing on Room-temperature grown ITO.pdf current
- 11:04, 28 July 2016 diff hist +22 Sputtering Recipes →ITO deposition (E-Beam-2)
- 11:01, 28 July 2016 diff hist +108 Sputtering Recipes
- 10:55, 28 July 2016 diff hist 0 Vacuum Deposition Recipes
- 10:54, 28 July 2016 diff hist +2 Vacuum Deposition Recipes
- 10:53, 28 July 2016 diff hist +24 Vacuum Deposition Recipes
- 16:17, 18 July 2016 diff hist +40 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:16, 18 July 2016 diff hist -40 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 11:00, 11 July 2016 diff hist 0 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:03, 17 June 2016 diff hist +2 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:18, 3 June 2016 diff hist +38 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:15, 3 June 2016 diff hist +76 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:40, 17 February 2016 diff hist 0 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:25, 17 February 2016 diff hist +25 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:24, 17 February 2016 diff hist 0 N File:50-InP Etch-2-17-2016.pdf current
- 16:21, 17 February 2016 diff hist +67 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 16:41, 16 February 2016 diff hist -47 Contact Alignment Recipes →SU-8-2005,2010,2015 Lithographic Recipes
- 16:39, 16 February 2016 diff hist +2 Contact Alignment Recipes →SU-8-2005,2010,2015 Lithographic Recipes
- 16:39, 16 February 2016 diff hist 0 N File:49-Photolithography of SU8-2015-a.pdf current
- 16:34, 16 February 2016 diff hist +35 Contact Alignment Recipes →SU-8-2005,2010,2015 Lithographic Recipes
- 16:31, 16 February 2016 diff hist +35 Contact Alignment Recipes →SU-8-2005,2010,2015 Lithographic Recipes
- 16:30, 16 February 2016 diff hist 0 N File:48-Photolithography of SU8-2010.pdf current
- 16:30, 16 February 2016 diff hist +58 Contact Alignment Recipes →SU-8-2005,2010,2015 Lithographic Recipes
- 16:27, 16 February 2016 diff hist +54 Lithography Recipes →Photolithography Recipes
- 16:23, 16 February 2016 diff hist +35 Contact Alignment Recipes →SU-8-2005,2010,2015 Lithographic Recipes
- 16:22, 16 February 2016 diff hist 0 N File:47-Photolithography of SU8-2005.pdf current
- 16:20, 16 February 2016 diff hist -154 Contact Alignment Recipes →SU-8-2005,2010,2015 recepes
- 16:18, 16 February 2016 diff hist +230 Contact Alignment Recipes
- 16:12, 16 February 2016 diff hist +6 Lithography Recipes →Photolithography Recipes
- 16:11, 16 February 2016 diff hist +6 Lithography Recipes →Chemical Datasheets
- 15:45, 8 January 2016 diff hist +94 Sputtering Recipes →Sputter 3 (AJA ATC 2000-F)
- 17:23, 16 December 2015 diff hist -26 Vacuum Deposition Recipes
- 17:06, 16 December 2015 diff hist 0 Sputtering Recipes →Sputter 3 (AJA ATC 2000-F)
- 17:00, 16 December 2015 diff hist +1 Vacuum Deposition Recipes
- 16:55, 16 December 2015 diff hist -1 Sputtering Recipes
- 16:52, 16 December 2015 diff hist +100 Sputtering Recipes →Sputter 3 (AJA ATC 2000-F)
- 16:50, 16 December 2015 diff hist +1 Vacuum Deposition Recipes
- 16:48, 16 December 2015 diff hist +4 Vacuum Deposition Recipes
- 16:46, 16 December 2015 diff hist +19 Vacuum Deposition Recipes
- 16:43, 16 December 2015 diff hist +29 Sputtering Recipes →Mo Deposition (Sputter 3)
- 16:42, 16 December 2015 diff hist 0 N File:46-Mo Film using Sputter3.pdf current
- 16:42, 16 December 2015 diff hist +67 Sputtering Recipes →Sputter 3 (AJA ATC 2000-F)
- 16:32, 1 December 2015 diff hist +76 Dry Etching Recipes
- 16:27, 1 December 2015 diff hist +64 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 16:25, 1 December 2015 diff hist +27 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 16:23, 1 December 2015 diff hist 0 N File:45-Etching Nickel with Al2O3 Mask using Oxford Ion Mill Tool.pdf current
- 16:00, 9 October 2015 diff hist +3 Dry Etching Recipes
- 15:58, 9 October 2015 diff hist -150 Dry Etching Recipes
- 15:58, 9 October 2015 diff hist +339 Dry Etching Recipes
- 15:54, 9 October 2015 diff hist +62 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 15:53, 9 October 2015 diff hist +27 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 15:52, 9 October 2015 diff hist +73 Dry Etching Recipes
- 15:49, 9 October 2015 diff hist 0 N File:44-Etching Gold with Al2O3 Mask using Oxford Ion Mill Tool.pdf current
- 14:37, 2 September 2015 diff hist +5 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 14:36, 2 September 2015 diff hist 0 N File:43-Issue with the etch of InP-InGaAs-and- InAlAs-b.pdf current
- 14:30, 2 September 2015 diff hist +2 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 14:09, 2 September 2015 diff hist +2 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 14:08, 2 September 2015 diff hist +121 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 14:26, 22 July 2015 diff hist +23 Dry Etching Recipes
- 14:24, 22 July 2015 diff hist +51 Dry Etching Recipes
- 14:19, 22 July 2015 diff hist +105 Dry Etching Recipes
- 14:16, 22 July 2015 diff hist +87 Dry Etching Recipes
- 14:09, 22 July 2015 diff hist +2 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 14:08, 22 July 2015 diff hist 0 N File:42-Etching Platinum using Oxford Ion Mill Tool-a.pdf current
- 14:03, 22 July 2015 diff hist -17 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 14:03, 22 July 2015 diff hist -9 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 14:02, 22 July 2015 diff hist +50 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 14:01, 22 July 2015 diff hist +53 Other Dry Etching Recipes →CAIBE (Oxford Ion Mill)
- 13:58, 22 July 2015 diff hist 0 N File:42-Etching Platinum using Oxford Ion Mill Tool.pdf current
- 13:42, 30 June 2015 diff hist +64 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 13:41, 30 June 2015 diff hist +63 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 12:12, 30 June 2015 diff hist +4 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 12:08, 30 June 2015 diff hist +8 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 12:07, 30 June 2015 diff hist 0 N File:39-Medium-stress SiNx at 100C using Unaxis ICP deposition tool.pdf current
- 11:57, 30 June 2015 diff hist +65 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 11:55, 30 June 2015 diff hist 0 N File:38-High-stress SiNx at 100 C using Unaxis ICP deposition tool.pdf current
- 11:40, 30 June 2015 diff hist +64 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 11:39, 30 June 2015 diff hist 0 N File:37-Low-stress SiNx at 100 C using Unaxis ICP deposition tool.pdf current
- 11:17, 30 June 2015 diff hist +157 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 11:15, 30 June 2015 diff hist +155 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 16:20, 29 June 2015 diff hist +116 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 16:19, 29 June 2015 diff hist +81 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 16:18, 29 June 2015 diff hist +80 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 16:16, 29 June 2015 diff hist +58 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 16:15, 29 June 2015 diff hist 0 N File:36-Medium-stress SiNx using Unaxis ICP deposition tool.pdf current
- 16:10, 29 June 2015 diff hist +81 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 15:59, 29 June 2015 diff hist +65 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 15:59, 29 June 2015 diff hist 0 N File:34-High-stress SiNx at 250 C using Unaxis ICP deposition tool.pdf current
- 15:58, 29 June 2015 diff hist +78 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 15:32, 29 June 2015 diff hist -67 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 15:30, 29 June 2015 diff hist +12 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 15:28, 29 June 2015 diff hist +64 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 15:27, 29 June 2015 diff hist 0 N File:35-Low-stress SiNx at 250 C using Unaxis ICP deposition tool.pdf current
- 15:24, 29 June 2015 diff hist +67 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 14:44, 29 June 2015 diff hist +67 PECVD Recipes →SiN (2% SiH4 - No-Ar)
- 15:14, 22 June 2015 diff hist +6 Lithography Recipes →Chemical Datasheets
- 15:12, 22 June 2015 diff hist +32 Lithography Recipes →Chemical Datasheets
- 15:12, 22 June 2015 diff hist 0 N File:3600 D, D2v Spin Speed Curve.pdf current
- 15:11, 22 June 2015 diff hist +23 Lithography Recipes →Chemical Datasheets
- 15:10, 22 June 2015 diff hist 0 N File:THMR iP 3500 iP3600.pdf current
- 15:10, 22 June 2015 diff hist +100 Lithography Recipes →Chemical Datasheets
- 15:07, 22 June 2015 diff hist +40 Lithography Recipes →Chemical Datasheets
- 15:06, 22 June 2015 diff hist 0 N File:THMR-iP3600 HP D 20140801 (B) GHS US.pdf current
- 15:05, 22 June 2015 diff hist +8 Lithography Recipes →Chemical Datasheets
- 11:20, 8 April 2015 diff hist +55 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:36, 8 April 2015 diff hist +4 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:34, 8 April 2015 diff hist +1 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:32, 8 April 2015 diff hist 0 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:30, 8 April 2015 diff hist +103 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:29, 8 April 2015 diff hist +106 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:34, 3 April 2015 diff hist +105 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:30, 3 April 2015 diff hist +104 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:26, 27 January 2015 diff hist +43 ICP Etching Recipes →SiO2 Etching (Panasonic 2)
- 10:24, 27 January 2015 diff hist +1 ICP Etching Recipes →SiO2 Etching (Panasonic 2)
- 10:24, 27 January 2015 diff hist +83 ICP Etching Recipes →SiO2 Etching (Panasonic 2)
- 10:21, 27 January 2015 diff hist 0 N File:33-Etching SiO2 with Vertical Side-wall.pdf current
- 09:23, 21 January 2015 diff hist +48 ICP Etching Recipes →Al Etch (Panasonic 1)
- 09:22, 21 January 2015 diff hist 0 N File:32-Reducing AlCl3 Corrosion with CHF3 plasma.pdf current
- 09:21, 21 January 2015 diff hist -51 ICP Etching Recipes →Al Etch (Panasonic 1)
- 09:12, 21 January 2015 diff hist +52 ICP Etching Recipes →Al Etch (Panasonic 1)
- 09:10, 21 January 2015 diff hist +59 ICP Etching Recipes →Al Etch (Panasonic 1)
- 14:23, 18 April 2014 diff hist +64 Lithography Recipes →Holography Recipes
- 14:22, 18 April 2014 diff hist 0 N File:31-Holography Process for 1D-lines and 2D-dots-rev-3-13-2014.pdf current
- 14:16, 18 April 2014 diff hist -36 Lithography Recipes →Holography Recipes
- 14:12, 18 April 2014 diff hist +74 Lithography Recipes →Holography Recipes
- 14:11, 18 April 2014 diff hist 0 N File:30-Redicing Nanowire Diameter by Thermal Oxidation and Vapored HF Etch.pdf current
- 14:11, 18 April 2014 diff hist +78 Lithography Recipes →Holography Recipes
- 16:11, 17 April 2014 diff hist +96 PECVD Recipes →SiO2 (2% SiH4 - No Ar)
- 16:10, 17 April 2014 diff hist 0 N File:29-UnaxisPM3-SiO2-SiH4-O2-He.pdf current
- 16:10, 17 April 2014 diff hist +151 PECVD Recipes →SiO2 (2% SiH4 - No Ar)
- 15:29, 18 March 2014 diff hist +51 PECVD Recipes →SiN (2% SiH4)
- 15:28, 18 March 2014 diff hist 0 N File:28-Very-low-pin-hole-density SiNx film at 300 C.pdf current
- 15:28, 18 March 2014 diff hist +61 PECVD Recipes →SiN (2% SiH4)
- 15:10, 18 March 2014 diff hist +47 PECVD Recipes →SiN (100% SiH4 )
- 15:09, 18 March 2014 diff hist 0 N File:27-SiNx Film (Bias=50W) Sidewall Coverage.pdf current
- 15:08, 18 March 2014 diff hist -57 PECVD Recipes →SiN (100% SiH4 )
- 14:04, 18 March 2014 diff hist +3 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 14:03, 18 March 2014 diff hist 0 N File:23-Tungsten Sputtering Film-Sputter-4-Ar.pdf current
- 17:06, 31 January 2014 diff hist +3 Vapor HF Etch →About
- 17:05, 31 January 2014 diff hist +9 Vapor HF Etch →About
- 16:25, 31 January 2014 diff hist +4 Vapor HF Etch →About
- 16:24, 31 January 2014 diff hist -3 Vapor HF Etch →About
- 16:24, 31 January 2014 diff hist 0 Tool List →Dry Etch
- 15:51, 31 January 2014 diff hist +4 HF Vapor Etch →About current
- 15:49, 31 January 2014 diff hist -3 HF Vapor Etch →About
- 15:37, 31 January 2014 diff hist +62 HF Vapor Etch →Documentation
- 15:37, 31 January 2014 diff hist +62 HF Vapor Etch →Documentation
- 15:36, 31 January 2014 diff hist -124 HF Vapor Etch →Documentation
- 09:04, 31 January 2014 diff hist 0 Vapor HF Etch →Documentation
- 09:03, 31 January 2014 diff hist 0 Vapor HF Etch →Documentation
- 17:13, 30 January 2014 diff hist +1,398 N Vapor HF Etch Created page with "{{tool|{{PAGENAME}} |picture=IMG_2416_1.jpg |type = Dry Etch |super= Mike Silva |phone=(805)839-3918x219 |location=Bay 2 |email=silva@ece.ucsb.edu |description = Vapor HF Etch..."
- 17:10, 30 January 2014 diff hist -8 Dry Etching Recipes
- 17:08, 30 January 2014 diff hist -1 Dry Etching Recipes
- 17:07, 30 January 2014 diff hist -7 Dry Etching Recipes
- 16:59, 30 January 2014 diff hist 0 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 16:59, 30 January 2014 diff hist 0 N File:26-Dry Etch of Unaxis ICP-grown SiO2 using Vapor HF tool-b.pdf current
- 16:58, 30 January 2014 diff hist 0 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 16:57, 30 January 2014 diff hist 0 N File:25-Dry Etch of Unaxis ICP-grown SiO2 using Vapor HF tool-a.pdf current
- 16:44, 30 January 2014 diff hist +37 HF Vapor Etch →Documentation
- 16:44, 30 January 2014 diff hist 0 N File:SPTS-Primaxx uEtch Presentation-b.pdf current
- 16:43, 30 January 2014 diff hist +26 HF Vapor Etch →Documentation
- 16:43, 30 January 2014 diff hist +37 HF Vapor Etch →Documentation
- 16:41, 30 January 2014 diff hist 0 N File:SPTS-Primaxx uEtch Presentation-a.pdf current
- 16:41, 30 January 2014 diff hist -22 Vapor HF Etch (uETCH) →Documentation current
- 12:48, 30 January 2014 diff hist -5 HF Vapor Etch →Documentation
- 12:47, 30 January 2014 diff hist +62 HF Vapor Etch →Documentation
- 12:47, 30 January 2014 diff hist +67 HF Vapor Etch →Documentation
- 12:45, 30 January 2014 diff hist -7 HF Vapor Etch →Documentation
- 12:43, 30 January 2014 diff hist -1 HF Vapor Etch
- 12:40, 30 January 2014 diff hist -50 HF Vapor Etch
- 12:40, 30 January 2014 diff hist +64 HF Vapor Etch
- 12:39, 30 January 2014 diff hist 0 N File:IMG 2416 1.jpg current
- 12:38, 30 January 2014 diff hist -14 HF Vapor Etch
- 12:36, 30 January 2014 diff hist -53 HF Vapor Etch
- 12:35, 30 January 2014 diff hist +58 HF Vapor Etch
- 12:27, 30 January 2014 diff hist -1 HF Vapor Etch
- 12:07, 30 January 2014 diff hist +10 HF Vapor Etch
- 12:06, 30 January 2014 diff hist -13 HF Vapor Etch
- 11:55, 30 January 2014 diff hist +11 HF Vapor Etch
- 11:53, 30 January 2014 diff hist +450 HF Vapor Etch
- 11:39, 30 January 2014 diff hist -1 HF Vapor Etch
- 11:33, 30 January 2014 diff hist -839 HF Vapor Etch
- 11:13, 30 January 2014 diff hist +1 HF Vapor Etch
- 11:06, 30 January 2014 diff hist +12 HF Vapor Etch
- 10:58, 30 January 2014 diff hist +26 HF Vapor Etch
- 10:55, 30 January 2014 diff hist -2 HF Vapor Etch
- 10:53, 30 January 2014 diff hist -24 HF Vapor Etch
- 10:41, 30 January 2014 diff hist +1,490 N Vapor HF Etch (uETCH) Created page with " XeF2 Etch (Xetch) Jump to: navigation, search XeF2 Etch (Xetch) XeF2.jpg Tool Type Dry Etch Location Bay 2 Supervisor Don Freeborn Supervisor Phone (805) 893-3918x216 Sup..."
- 10:29, 30 January 2014 diff hist 0 Dry Etching Recipes
- 10:29, 30 January 2014 diff hist 0 Dry Etching Recipes
- 10:17, 30 January 2014 diff hist +5 Dry Etching Recipes
- 10:15, 30 January 2014 diff hist +1 Dry Etching Recipes
- 10:13, 30 January 2014 diff hist +12 Dry Etching Recipes
- 10:09, 30 January 2014 diff hist +1 Dry Etching Recipes
- 10:07, 30 January 2014 diff hist +62 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 10:06, 30 January 2014 diff hist +4 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 10:04, 30 January 2014 diff hist -69 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 10:04, 30 January 2014 diff hist +41 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 10:03, 30 January 2014 diff hist +130 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 17:03, 28 January 2014 diff hist +13 Other Dry Etching Recipes →Vapor HF Etch (uETCH)
- 17:00, 28 January 2014 diff hist +56 Other Dry Etching Recipes →XeF2 Etch (Xetch)
- 16:56, 28 January 2014 diff hist +47 Dry Etching Recipes
- 16:53, 28 January 2014 diff hist +4 Dry Etching Recipes
- 16:48, 28 January 2014 diff hist +74 Dry Etching Recipes
- 16:46, 28 January 2014 diff hist +8 Dry Etching Recipes
- 16:44, 28 January 2014 diff hist +36 Dry Etching Recipes
- 16:40, 28 January 2014 diff hist +10 Dry Etching Recipes
- 16:37, 28 January 2014 diff hist +12 Dry Etching Recipes
- 16:36, 28 January 2014 diff hist +4 Dry Etching Recipes
- 16:35, 28 January 2014 diff hist +2 Dry Etching Recipes
- 16:32, 28 January 2014 diff hist +2 Dry Etching Recipes
- 16:28, 28 January 2014 diff hist +96 Dry Etching Recipes
- 16:23, 28 January 2014 diff hist -11 Dry Etching Recipes
- 16:22, 28 January 2014 diff hist +12 Dry Etching Recipes
- 12:30, 5 November 2013 diff hist +47 Vacuum Deposition Recipes
- 12:29, 5 November 2013 diff hist +47 Vacuum Deposition Recipes
- 12:25, 5 November 2013 diff hist +38 Sputtering Recipes →Sputter 3 (AJA ATC 2000-F)
- 12:23, 5 November 2013 diff hist 0 N File:24-Ni and Ta Films using Sputter-3.pdf current
- 12:23, 5 November 2013 diff hist +80 Sputtering Recipes →Sputter 3 (AJA ATC 2000-F)
- 16:12, 4 November 2013 diff hist +45 Vacuum Deposition Recipes
- 16:10, 4 November 2013 diff hist +41 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 16:09, 4 November 2013 diff hist +64 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V)
- 10:26, 28 October 2013 diff hist 0 Vacuum Deposition Recipes
- 10:24, 28 October 2013 diff hist +48 Vacuum Deposition Recipes
- 10:22, 28 October 2013 diff hist +26 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 10:22, 28 October 2013 diff hist 0 N File:22-TiO2-Film-Sputter-2.pdf current
- 10:21, 28 October 2013 diff hist +93 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 10:41, 10 October 2013 diff hist -1 Vacuum Deposition Recipes
- 10:40, 10 October 2013 diff hist +48 Vacuum Deposition Recipes
- 10:38, 10 October 2013 diff hist +40 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 10:37, 10 October 2013 diff hist 0 N File:21-Au-Sputter-film-recipes-Sputter-2.pdf current
- 10:37, 10 October 2013 diff hist +66 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 09:21, 7 October 2013 diff hist +47 Vacuum Deposition Recipes
- 09:19, 7 October 2013 diff hist +35 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 09:19, 7 October 2013 diff hist 0 N File:20-Al-Sputtering-Film-Sputter-2.pdf current
- 09:18, 7 October 2013 diff hist +66 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 09:09, 7 October 2013 diff hist -1 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 09:07, 7 October 2013 diff hist -13 Vacuum Deposition Recipes
- 09:05, 7 October 2013 diff hist +60 Vacuum Deposition Recipes
- 09:02, 7 October 2013 diff hist +36 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 09:02, 7 October 2013 diff hist 0 N File:19-AlN-Sputtering-Film-Sputter-2.pdf current
- 09:01, 7 October 2013 diff hist 0 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 09:01, 7 October 2013 diff hist +24 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 08:56, 7 October 2013 diff hist 0 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 08:56, 7 October 2013 diff hist +69 Sputtering Recipes →Sputter 2 (SFI Endeavor)
- 14:48, 3 October 2013 diff hist +8 Contact Alignment Recipes
- 14:39, 3 October 2013 diff hist +9 Contact Alignment Recipes
- 14:36, 3 October 2013 diff hist +54 Lithography Recipes →Photolithography Recipes
- 14:33, 3 October 2013 diff hist +126 Contact Alignment Recipes
- 10:41, 3 October 2013 diff hist +32 ICP Etching Recipes →InP Etch
- 10:40, 3 October 2013 diff hist 0 N File:18-InP-based etching-Cl2N2Ar.pdf current
- 10:40, 3 October 2013 diff hist +15 ICP Etching Recipes →InP Etch
- 10:39, 3 October 2013 diff hist +37 ICP Etching Recipes →InP Etch
- 08:20, 3 October 2013 diff hist +43 ICP Etching Recipes →InP Etch (H2 Ar)
- 08:19, 3 October 2013 diff hist 0 N File:17-InP&InGaAs etch-Cl2H2Ar-Unaxis-VLR.pdf current
- 08:18, 3 October 2013 diff hist +61 ICP Etching Recipes →InP Etch (H2 Ar)
- 16:14, 2 October 2013 diff hist +50 Dry Etching Recipes
- 16:11, 2 October 2013 diff hist +22 ICP Etching Recipes →GaAs Etch (Panasonic 2)
- 16:11, 2 October 2013 diff hist 0 N File:16-GaAs etch-ICP-2.pdf current
- 16:10, 2 October 2013 diff hist +74 ICP Etching Recipes →ICP Etch 2 (Panasonic E640)
- 13:50, 2 October 2013 diff hist +50 Dry Etching Recipes
- 13:48, 2 October 2013 diff hist +41 ICP Etching Recipes →ICP-Etch (Unaxis VLR)
- 13:47, 2 October 2013 diff hist 0 N File:14-AlAs-GR-cal etch-Unaxis ICP etcher.pdf current
- 13:47, 2 October 2013 diff hist +56 ICP Etching Recipes →ICP-Etch (Unaxis VLR)
- 13:44, 2 October 2013 diff hist +49 Dry Etching Recipes
- 13:41, 2 October 2013 diff hist +34 ICP Etching Recipes →ICP-Etch (Unaxis VLR)
- 13:41, 2 October 2013 diff hist 0 N File:15-GaAs etch-Unaxis ICP etcher.pdf current
- 13:40, 2 October 2013 diff hist +52 ICP Etching Recipes →ICP-Etch (Unaxis VLR)
- 11:29, 2 October 2013 diff hist +46 Dry Etching Recipes
- 11:27, 2 October 2013 diff hist +32 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 11:26, 2 October 2013 diff hist 0 N File:13-GaAs-AlGaAs Etching-RIE-5.pdf current
- 11:25, 2 October 2013 diff hist -146 RIE Etching Recipes →AlGaAs Etching (RIE 5)=
- 11:25, 2 October 2013 diff hist +86 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 11:25, 2 October 2013 diff hist +59 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 11:23, 2 October 2013 diff hist -146 RIE Etching Recipes →AlGaAs Etching (RIE 5)=
- 11:22, 2 October 2013 diff hist -146 RIE Etching Recipes →AlGaAs Etching (RIE 5)=
- 11:22, 2 October 2013 diff hist +146 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 11:21, 2 October 2013 diff hist +147 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 11:20, 2 October 2013 diff hist +59 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 11:02, 2 October 2013 diff hist +52 Dry Etching Recipes
- 10:59, 2 October 2013 diff hist +54 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I)
- 10:58, 2 October 2013 diff hist 0 N File:12-Plasma Etching of AlGaAs-Panasonic ICP-1-Etcher.pdf current
- 10:57, 2 October 2013 diff hist +63 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I)
- 11:17, 27 September 2013 diff hist +20 RIE Etching Recipes →CdZnTe Etching (RIE 2)
- 11:16, 27 September 2013 diff hist 0 N File:11-CZT etching-1.pdf current
- 11:16, 27 September 2013 diff hist +60 RIE Etching Recipes →RIE 2 (MRC)
- 11:14, 27 September 2013 diff hist +46 Dry Etching Recipes
- 11:13, 27 September 2013 diff hist +2 Dry Etching Recipes
- 11:09, 25 September 2013 diff hist +8 ICP Etching Recipes →Si Deep RIE (PlasmaTherm/Bosch Etch)
- 10:04, 25 September 2013 diff hist +59 Dry Etching Recipes
- 10:00, 25 September 2013 diff hist +39 ICP Etching Recipes →Si Deep RIE (PlasmaTherm/Bosch Etch)
- 09:59, 25 September 2013 diff hist 0 N File:10-Si Etch using DRIE (single-step).pdf current
- 09:57, 25 September 2013 diff hist +146 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I)
- 14:16, 24 September 2013 diff hist +48 Dry Etching Recipes
- 14:14, 24 September 2013 diff hist +38 ICP Etching Recipes →GaN Etch (Unaxis VLR)
- 14:13, 24 September 2013 diff hist 0 N File:09-Plasma Etching of GaN-UnaxisPM1.pdf current
- 14:12, 24 September 2013 diff hist +60 ICP Etching Recipes →ICP-Etch (Unaxis VLR)
- 09:44, 24 September 2013 diff hist +1 Dry Etching Recipes
- 09:40, 24 September 2013 diff hist -99 ICP Etching Recipes →XeF2 Etch (Xetch)
- 09:39, 24 September 2013 diff hist +74 Other Dry Etching Recipes
- 09:38, 24 September 2013 diff hist +23 N Other Dry Etching Recipes Created page with "{{recipes|Dry Etching}}"
- 09:36, 24 September 2013 diff hist -2 Dry Etching Recipes
- 09:35, 24 September 2013 diff hist +14 Dry Etching Recipes
- 09:21, 24 September 2013 diff hist -4 ICP Etching Recipes
- 09:21, 24 September 2013 diff hist +28 ICP Etching Recipes
- 15:50, 19 September 2013 diff hist -111 ICP Etching Recipes →RIE Etch 5 (RIE#5)
- 15:49, 19 September 2013 diff hist +1 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 15:48, 19 September 2013 diff hist 0 RIE Etching Recipes →GaN Etching (RIE#5)
- 15:48, 19 September 2013 diff hist -25 RIE Etching Recipes →RIE Etch 5 (RIE#5)
- 15:47, 19 September 2013 diff hist +111 RIE Etching Recipes →RIE 5 (PlasmaTherm)
- 15:44, 19 September 2013 diff hist +43 Dry Etching Recipes
- 15:41, 19 September 2013 diff hist +33 ICP Etching Recipes →RIE Etch 5 (RIE#5)
- 15:40, 19 September 2013 diff hist 0 N File:08-Plasma Etching of GaN-RIE5.pdf current
- 15:38, 19 September 2013 diff hist +78 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I)
- 16:13, 18 September 2013 diff hist +1 Dry Etching Recipes
- 16:13, 18 September 2013 diff hist +1 Dry Etching Recipes
- 16:11, 18 September 2013 diff hist -2 Dry Etching Recipes
- 16:08, 18 September 2013 diff hist +1 Dry Etching Recipes
- 16:06, 18 September 2013 diff hist +19 Dry Etching Recipes
- 16:00, 18 September 2013 diff hist -1 ICP Etching Recipes →XeF2 Etch (Xetch)
- 15:58, 18 September 2013 diff hist -11 ICP Etching Recipes →XeF2 Etch (Xetch)
- 15:58, 18 September 2013 diff hist +1 ICP Etching Recipes →XeF2 Etch (Xetch)
- 15:56, 18 September 2013 diff hist -1 ICP Etching Recipes →XeF2 Etch (Xetch))
- 15:55, 18 September 2013 diff hist -1 ICP Etching Recipes →XeF22 Etch (Xetch))
- 15:55, 18 September 2013 diff hist +12 ICP Etching Recipes →XeF2 Etch (Xetch))
- 15:54, 18 September 2013 diff hist -3 ICP Etching Recipes
- 15:51, 18 September 2013 diff hist -9 ICP Etching Recipes →Si-Etch (XeF2 Etch (Xetch))
- 15:49, 18 September 2013 diff hist +3 ICP Etching Recipes →Si-Etch (XeF2 Etch (Xetch))
- 15:45, 18 September 2013 diff hist +31 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I)
- 15:44, 18 September 2013 diff hist +1 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I)
- 15:42, 18 September 2013 diff hist 0 N File:07-GaN Etch-Panasonic-ICP-1.pdf current
- 15:19, 18 September 2013 diff hist +56 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I)
- 15:16, 18 September 2013 diff hist +29 Dry Etching Recipes
- 11:42, 17 September 2013 diff hist -47 ICP Etching Recipes →Si-Etch (XeF2 Etch (Xetch))
- 11:42, 17 September 2013 diff hist +49 ICP Etching Recipes →Si Etch (XeF2 Etch (Xetch))
- 11:37, 17 September 2013 diff hist +23 ICP Etching Recipes →Si Etch (XeF2 Etch (Xetch))
- 11:36, 17 September 2013 diff hist 0 N File:06-XeF2-etch-recipe.pdf current
- 11:35, 17 September 2013 diff hist +6 ICP Etching Recipes →Si Etch (XeF2 Etcher)
- 11:33, 17 September 2013 diff hist +54 ICP Etching Recipes →InP Etch (Unaxis VLR)
- 11:30, 17 September 2013 diff hist +1 Dry Etching Recipes
- 11:29, 17 September 2013 diff hist +48 Dry Etching Recipes
- 09:08, 17 September 2013 diff hist +31 Lithography Recipes →Holography Recipes
- 09:07, 17 September 2013 diff hist 0 N File:05-SiO2 Nano-structure Etch.pdf current
- 09:05, 17 September 2013 diff hist -31 Lithography Recipes →Holography Recipes
- 09:04, 17 September 2013 diff hist +31 Lithography Recipes →Holography Recipes
- 09:03, 17 September 2013 diff hist -31 Lithography Recipes →Holography Recipes
- 16:14, 13 September 2013 diff hist +31 Lithography Recipes →Holography Recipes
- 16:12, 13 September 2013 diff hist +107 Lithography Recipes →Holography Recipes
- 16:09, 11 September 2013 diff hist +1 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 16:08, 11 September 2013 diff hist 0 N File:02-ICP-PECVD-a-Si Film-90C.pdf current
- 16:04, 11 September 2013 diff hist +27 PECVD Recipes →Amorphous-Si deposition (PECVD #2)
- 16:03, 11 September 2013 diff hist 0 N File:03-Amorphous-Si-PECVD-2.pdf current
- 16:02, 11 September 2013 diff hist -22 PECVD Recipes →PECVD 2 (Advanced Vacuum)
- 15:20, 11 September 2013 diff hist +50 Vacuum Deposition Recipes
- 15:12, 11 September 2013 diff hist +108 PECVD Recipes →PECVD 2 (Advanced Vacuum)
- 14:39, 11 September 2013 diff hist 0 N File:01-ICP-PECVD-a-Si-Deposition Recipe-250C.pdf current
- 13:55, 11 September 2013 diff hist +14 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 13:48, 11 September 2013 diff hist -2 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 13:45, 11 September 2013 diff hist +2 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 13:18, 11 September 2013 diff hist +28 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 13:15, 11 September 2013 diff hist +43 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 13:12, 11 September 2013 diff hist -73 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 15:45, 4 September 2013 diff hist -2 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 15:35, 4 September 2013 diff hist +2 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 15:32, 4 September 2013 diff hist -2 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 15:26, 4 September 2013 diff hist +2 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 15:11, 4 September 2013 diff hist -3 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 14:53, 4 September 2013 diff hist +53 Vacuum Deposition Recipes
- 11:59, 4 September 2013 diff hist +6 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 11:41, 4 September 2013 diff hist -28 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 11:28, 4 September 2013 diff hist -13 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 11:13, 4 September 2013 diff hist -203 PECVD Recipes
- 11:07, 4 September 2013 diff hist -20 PECVD Recipes
- 11:06, 4 September 2013 diff hist +20 PECVD Recipes →Amorphous Si (100%SiH4 Ar He)
- 11:00, 4 September 2013 diff hist -1 PECVD Recipes →Amorphous Si (100% SiH4 Ar He)
- 11:00, 4 September 2013 diff hist -191 PECVD Recipes →Amorphous Si (100% SiH4 Ar He)
- 10:57, 4 September 2013 diff hist -29 PECVD Recipes
- 10:56, 4 September 2013 diff hist +877 PECVD Recipes
- 10:43, 4 September 2013 diff hist -9 m Vacuum Deposition Recipes Reverted edits by Ningcao (talk) to last revision by John d
- 10:41, 4 September 2013 diff hist +9 Vacuum Deposition Recipes
- 08:10, 13 July 2012 diff hist +5 N User talk:Ningcao Created page with "blank" current