User contributions
Jump to navigation
Jump to search
- 16:16, 11 October 2018 diff hist +2 Lithography Recipes →Holography Recipes
- 16:15, 11 October 2018 diff hist 0 N File:Holography Process for 1D-lines and 2D-dots (ARC-11 & THMR-IP3600HP-D)-updated-8-13-2018-A.pdf current
- 08:37, 9 October 2018 diff hist +78 Test Data of etching SiO2 with CHF3/CF4 Tag: Visual edit
- 08:33, 9 October 2018 diff hist +41 Test Data of etching SiO2 with CHF3/CF4 Tag: Visual edit
- 08:30, 9 October 2018 diff hist -41 Test Data of etching SiO2 with CHF3/CF4 Tag: Visual edit
- 08:28, 9 October 2018 diff hist +80 Test Data of etching SiO2 with CHF3/CF4/O2 (using this recipe only for Fluorine etch of the underneath layer) Tag: Visual edit
- 08:25, 9 October 2018 diff hist +250 N Test Data of etching SiO2 with CHF3/CF4/O2 (using this recipe only for Fluorine etch of the underneath layer) Created page with "{| class="wikitable" | colspan="5" |ICP#2: 0.5Pa, 50/500W, CHF3/CF4/O2=35/5/10sccm, time=210 sec |- |Date |Sample# |Etch Rate (nm/min) |Etch Selectivity (SiO2/PR) |Averaged..." Tag: Visual edit
- 08:23, 9 October 2018 diff hist +1 ICP Etching Recipes →SiO2 Etching (Panasonic 2) Tag: Visual edit
- 08:17, 9 October 2018 diff hist +109 ICP Etching Recipes →SiO2 Etching (Panasonic 2): change the data title Tag: Visual edit
- 08:13, 9 October 2018 diff hist -4 Test Data of etching SiO2 with CHF3/CF4 add a data table Tag: Visual edit
- 08:09, 9 October 2018 diff hist +249 Test Data of etching SiO2 with CHF3/CF4 add a data table Tag: Visual edit
- 16:17, 8 October 2018 diff hist +251 Test Data of etching SiO2 with CHF3/CF4/O2 add a table current Tag: Visual edit
- 16:15, 8 October 2018 diff hist -83 ICP Etching Recipes →SiO2 Etching (Panasonic 1) Tag: Visual edit
- 15:48, 8 October 2018 diff hist +40 N Test Data of etching SiO2 with CHF3/CF4 add a data file Tag: Visual edit
- 15:46, 8 October 2018 diff hist 0 N File:SiO2 Etch using ICP2-no O2.pdf
- 15:45, 8 October 2018 diff hist +45 ICP Etching Recipes →SiO2 Etching (Panasonic 2): add a title Tag: Visual edit
- 15:44, 8 October 2018 diff hist +42 N Test Data of etching SiO2 with CHF3/CF4/O2 add data file Tag: Visual edit
- 15:42, 8 October 2018 diff hist +48 ICP Etching Recipes →SiO2 Etching (Panasonic 2): adding SiO2 etch test title Tag: Visual edit
- 15:36, 8 October 2018 diff hist +4 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I): add SiO2 test data Tag: Visual edit
- 15:32, 8 October 2018 diff hist +79 ICP Etching Recipes →SiO2 Etching (Panasonic 1): adding test data Tag: Visual edit