User contributions
Jump to navigation
Jump to search
- 08:55, 17 February 2021 diff hist +335 Template:Announcements ASML PM March 8th
- 10:03, 16 February 2021 diff hist +39 PECVD 2 (Advanced Vacuum) →Recipes: mention historical data Tag: Visual edit
- 04:50, 9 February 2021 diff hist +2 m MLA150 - Troubleshooting →Defocus: unable to enter ±25 full range: typo Tag: Visual edit
- 10:22, 8 February 2021 diff hist +38 Maskless Aligner (Heidelberg MLA150) →Detailed Specifications: added max write area Tag: Visual edit
- 12:27, 5 February 2021 diff hist +53 m MLA150 - Large Image GDS Generation Tag: Visual edit
- 12:05, 5 February 2021 diff hist +422 MLA150 - Troubleshooting added "Stage not centered" Tag: Visual edit
- 23:14, 2 February 2021 diff hist +248 ICP Etching Recipes →PlasmaTherm/SLR Fluorine Etcher: SiVertHF: note on removing Native SiO2 Tag: Visual edit
- 23:08, 2 February 2021 diff hist +73 ICP Etching Recipes added (Fluorine ICP Etcher) to titles Tag: Visual edit
- 17:18, 2 February 2021 diff hist 0 Stepper 3 (ASML DUV) corrected PanOpto video traing link Tag: Visual edit
- 18:11, 1 February 2021 diff hist +64 m Thermal Processing Recipes →Tystar 8300 Tag: Visual edit
- 18:08, 1 February 2021 diff hist +235 Tube Furnace (Tystar 8300) →Recipes: link to recipes page Tag: Visual edit
- 10:28, 1 February 2021 diff hist +255 Services →Request Remote Fabrication Services: separate "paperwork" section for Fab Svc Tag: Visual edit
- 10:22, 1 February 2021 diff hist +1,811 Services →Fabrication Services by NanoFab Staff: pasted Services text - same as the nanotech page. minor updates. Tag: Visual edit
- 10:13, 1 February 2021 diff hist 0 File:UCSB Service Agreement.pdf John d uploaded a new version of File:UCSB Service Agreement.pdf
- 10:09, 1 February 2021 diff hist +79 N Category:COVID description current Tag: Visual edit
- 11:08, 30 January 2021 diff hist +64 Process Group - Lab Stocking/Supplies Tasks Update: not needed. current Tag: Visual edit
- 11:07, 30 January 2021 diff hist +323 ASML Stepper 3 Dicing Guide Programming Update: state doesn’t work and workaround. current Tag: Visual edit
- 06:24, 27 January 2021 diff hist +964 ICP Etching Recipes →High Rate Bosch Etch (DSEIII): Bsoch PR selectivity, tips to reduce black silicon, edge bead removal process link Tag: Visual edit
- 06:21, 27 January 2021 diff hist +28 ASML DUV: Edge Bead Removal via Photolithography credits and date Tag: Visual edit
- 06:18, 27 January 2021 diff hist +138 ASML DUV: Edge Bead Removal via Photolithography note on I-line process Tag: Visual edit