PECVD1 Recipes

From UCSB Nanofab Wiki
Jump to navigation Jump to search

PECVD 1 (PlasmaTherm 790)

SiN deposition (PECVD #1)

  • Deposition rate~11.30nm/min (users must calibrate this prior to critical deps)
  • HF e.r.~90nm/min
  • Stress~444MPa
  • Refractive Index~1.940

SiO2 deposition (PECVD #1)

  • Deposition rate~35.41nm/min (users must calibrate this prior to critical deps)
  • HF e.r.~669nm/min
  • Stress~-414MPa
  • Refractive Index~1.460

SiOxNy deposition (PECVD #1)