{| class="wikitable sortable"
  +
|+List of all lab ovens and capabilities/uses
  +
!Oven Name + Link
  +
!Temperature Range/Capabilities
  +
!Programmable
  +
!Gases
  +
!Vacuum/Pressure Range
  +
!Typical Uses
  +
!SignupMonkey Reservation
  +
|-
  +
|[[Ovens 1, 2 & 3 (Labline)|Oven 1]]
  +
|
  +
* Typically 95°C
  +
* Passive Cooling
  +
|No, single temperature.
  +
|N/A
  +
|Atmosphere only
  +
|Drying glassware, general baking.
  +
|No. Users may change temperature.
  +
|-
  +
|[[Ovens 1, 2 & 3 (Labline)|Oven 2]]
  +
|
  +
* Typically 100°C
  +
* Passive Cooling
  +
|No, single temperature.
  +
|N/A
  +
|Atmosphere only
  +
|Drying glassware, general baking.
  +
|No. Users may change temperature.
  +
|-
  +
|[[Oven 4 (Thermo-Fisher HeraTherm)|Oven 4: HeraTherm Oven]]
  +
|
  +
|
  +
* Multi-step programmable
  +
* Ramp Rate: only low/med/high (not numeric ramp rate).
  +
* Gas flow not programmable
  +
|
  +
* N2 (manual flow setting)
  +
* Atmosphere Purge
  +
|Atmosphere only
  +
|Bonding, BCB/Polymer curing.
  +
|No
  +
Reserve with note in logbook.
  +
|-
  +
|[[High Temp Oven (Blue M)|Blue-M Oven]]
  +
|
  +
* Max. temp. 350°C
  +
* Passive Cooling
  +
|
  +
* Yes, fully programmable up to 2 stages.
  +
* Gas flow not programmable
  +
|
  +
* N2 (manual flow setting)
  +
|Atmosphere only
  +
|BCB/Polymer curing.
  +
|[http://signupmonkey.ece.ucsb.edu/cgi-bin/users/browse.cgi?tool_ID=56 Sign Up For This Tool]
  +
|-
  +
|[[Vacuum Oven (YES)|YES Vacuum Oven]]
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
 
|}

Revision as of 10:58, 4 June 2019

Ovens - Overview of All Lab Ovens
Tool Type Thermal Processing
Location various
Description Lab ovens
Manufacturer various
Thermal Processing Recipes


See the full list of Thermal Processing tools here.

List of all lab ovens and capabilities/uses
Oven Name + Link Temperature Range/Capabilities Programmable Gases Vacuum/Pressure Range Typical Uses SignupMonkey Reservation
Oven 1
  • Typically 95°C
  • Passive Cooling
No, single temperature. N/A Atmosphere only Drying glassware, general baking. No. Users may change temperature.
Oven 2
  • Typically 100°C
  • Passive Cooling
No, single temperature. N/A Atmosphere only Drying glassware, general baking. No. Users may change temperature.
Oven 4: HeraTherm Oven
  • Multi-step programmable
  • Ramp Rate: only low/med/high (not numeric ramp rate).
  • Gas flow not programmable
  • N2 (manual flow setting)
  • Atmosphere Purge
Atmosphere only Bonding, BCB/Polymer curing. No

Reserve with note in logbook.

Blue-M Oven
  • Max. temp. 350°C
  • Passive Cooling
  • Yes, fully programmable up to 2 stages.
  • Gas flow not programmable
  • N2 (manual flow setting)
Atmosphere only BCB/Polymer curing. Sign Up For This Tool