OLD - PECVD2 Recipes
PECVD 2 (Advanced Vacuum)
Photos
SiN deposition (PECVD #2)
SiO2 deposition (PECVD #2)
LS SiN deposition (PECVD #2)
- Deposition Rate: ≈ 7.87 nm/min (users must calibrate this prior to critical deps)
- Refractive Index: ≈ 1.938
- Stress ≈ 1.76MPa
- HF etch rate~47nm/min