Difference between revisions of "Molecular Vapor Deposition"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(→‎Recipes: link to new process traveler)
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{tool|{{PAGENAME}}
+
{{tool2|{{PAGENAME}}
 
|picture=MVD.jpg
 
|picture=MVD.jpg
 
|type = Vacuum Deposition
 
|type = Vacuum Deposition
 
|super= Lee Sawyer
 
|super= Lee Sawyer
  +
|super2= Aidan Hopkins
 
|phone=(805) 893-2123
 
|phone=(805) 893-2123
 
|location=Bay 4
 
|location=Bay 4
Line 15: Line 16:
 
==Recipes==
 
==Recipes==
   
*[https://wiki.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Nanoimprinting_Recipes Nanoimprinting recipes] using FDTS non-stick layer
+
*[https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Nanoimprinting_Recipes Nanoimprinting recipes] using FDTS non-stick layer
 
*[https://signupmonkey.ece.ucsb.edu/wiki/images/3/3c/MVD_Standard_Recipes.pdf MVD Standard Recipes]
 
*[https://signupmonkey.ece.ucsb.edu/wiki/images/3/3c/MVD_Standard_Recipes.pdf MVD Standard Recipes]
   

Latest revision as of 10:34, 30 August 2022

Molecular Vapor Deposition
MVD.jpg
Location Bay 4
Tool Type Vacuum Deposition
Manufacturer Applied Microstructures Inc.
Description Molecular Vapor Deposition System

Primary Supervisor Lee Sawyer
(805) 893-2123
lee_sawyer@ucsb.edu

Secondary Supervisor

Aidan Hopkins


Recipes Vacuum Deposition RecipesN/A


About

The Molecular Vapor deposition system is used for deposition of a monolayer-thick fluorocarbon film for producing extremely hydrophobic surfaces used for anti-sticking layers for nanoimprinting or anti-stiction layers for MEMS. The system has integrated Oxygen plasma cleaning for organic removal and surface activation and can be run at temperatures up to 80°C. Multi-step recipes can be created. The system is currently configured for FDTS (perflourodecyltricholorsilane) and water to producing the coatings. Up to 6” wafers can be coated in the system.

Recipes

Documentation