|picture=microscopes.jpg
 
|type = Inspection, Test and Characterization
 
|type = Inspection, Test and Characterization
|super= Tony Bosch
+
|super= Demis D. John
 
|location=Bay 3, 6 & 7
 
|location=Bay 3, 6 & 7
 
|description = Optical Microscopes
 
|description = Optical Microscopes
Line 10: Line 10:
 
== Procedures & Tools ==
 
== Procedures & Tools ==
 
===[[UCSB NanoFab Microscope Training|'''Microscope Training Guide''']]===
 
===[[UCSB NanoFab Microscope Training|'''Microscope Training Guide''']]===
Use the guide linked above for general usage info & the many advanced features available on most of our microscopes. New users are encouraged to read this, and also request in-person training by [[Demis D. John|Demis]].
+
The guide linked above explains general usage info & the many advanced features available on most of our microscopes. New users are encouraged to read this, and also request in-person training by [[Demis D. John|Demis]].
   
 
=== Image Analysis Software ===
 
=== Image Analysis Software ===
 
Many of our microscopes have cameras and software for image capture. If you know the ''microscope and objective'' used for acquiring a photo, you can make calibrated measurements on the photos at your own desktop using the following software:
 
Many of our microscopes have cameras and software for image capture. If you know the ''microscope and objective'' used for acquiring a photo, you can make calibrated measurements on the photos at your own desktop using the following software:
 
*[https://www.amscope.com/software-download AmScope Software] - microscope image analysis software
 
*[https://www.amscope.com/software-download AmScope Software] - microscope image analysis software
  +
**[[Amscope Quickstart Usage Guide]]
 
**AmScope Calibration File containing calibrations for all NanoFab microscopes: [https://wiki.nanotech.ucsb.edu/wiki/Images/uploads/2020/AmScopeCalsAll.magn Download Here]
 
**AmScope Calibration File containing calibrations for all NanoFab microscopes: [https://wiki.nanotech.ucsb.edu/wiki/Images/uploads/2020/AmScopeCalsAll.magn Download Here]
 
**Also available on '''''Nanofiles-SFTP / Manuals / Amscope'''''
 
**Also available on '''''Nanofiles-SFTP / Manuals / Amscope'''''
Line 25: Line 26:
 
The Nikon scopes have 3rd party cameras that are connected to computers via AM Scope software which allows users to digitally capture images through the microscope and make calibrated measurements.
 
The Nikon scopes have 3rd party cameras that are connected to computers via AM Scope software which allows users to digitally capture images through the microscope and make calibrated measurements.
   
===Microscope #2: Nikon Optiphot 200 (Bay 7)===
+
===Microscope #2: Nikon Optiphot 200 (Bay 2)===
   
 
*Trinocular: Ocular Binoc. + Camera (Simultaneous)
 
*Trinocular: Ocular Binoc. + Camera (Simultaneous)
Line 38: Line 39:
 
===Microscope #3: Nikon Eclipse L200 (Bay 6)===
 
===Microscope #3: Nikon Eclipse L200 (Bay 6)===
   
*[https://www.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Manual for Nikon Eclipse L200D]
+
*[https://wiki.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Manual for Nikon Eclipse L200D]
 
*Trinocular: Binoc. + Camera (Mutually Exclusive)
 
*Trinocular: Binoc. + Camera (Mutually Exclusive)
 
*Objectives: 5x, 10x, 20x, 50x, 100x, 150x
 
*Objectives: 5x, 10x, 20x, 50x, 100x, 150x
Line 60: Line 61:
   
 
The lab has two general purpose Olympus microscopes, and two specialized microscopes that require training to use, although both of these can also be used for general imaging.
 
The lab has two general purpose Olympus microscopes, and two specialized microscopes that require training to use, although both of these can also be used for general imaging.
[[File:Microscope 01 Olympus BHMJL crop.png|alt=Photo of Microscope #01 in the Characterization lab, Room 1111|thumb|200x200px|Microscope #01 in the Characterization lab, Room 1111]]
+
[[File:Microscope 01 Olympus BHMJL crop.png|alt=Photo of Microscope #01 in the Characterization lab, Room 1111|thumb|200x200px|Microscope #01]]
   
===Microscope #1: Olympus BHMJL (Char. Lab, Room 1111)===
+
===Microscope #1: Olympus BHMJL (Bay 4)===
   
 
*Trinocular: Ocular Binoc. + Camera (Exclusive)
 
*Trinocular: Ocular Binoc. + Camera (Exclusive)
Line 70: Line 71:
 
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
 
*Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
 
*AMScope 14MP Cameras with calibrated software for measurements. Software available for offline measurements: [https://www.amscope.com/software-download Link here].
 
*AMScope 14MP Cameras with calibrated software for measurements. Software available for offline measurements: [https://www.amscope.com/software-download Link here].
*User Manual: [https://www.nanotech.ucsb.edu/wiki/index.php/File:Olympus_-_BHM_Microscope_-_Instruction_Manual.pdf Olympus BHM Microscopes - Instruction Manual (PDF)]
+
*User Manual: [https://wiki.nanotech.ucsb.edu/wiki/index.php/File:Olympus_-_BHM_Microscope_-_Instruction_Manual.pdf Olympus BHM Microscopes - Instruction Manual (PDF)]
   
 
===Microscope #5: [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]]===
 
===Microscope #5: [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]]===
Line 86: Line 87:
 
*Three Fluorescence Filters (requires training, see main tool page for specs.)
 
*Three Fluorescence Filters (requires training, see main tool page for specs.)
   
===Microscope #6: [[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 7)]]===
+
===Microscope #6: [[Deep UV Optical Microscope (Olympus)|DUV Microscope: Olympus MX61A-DUV (Bay 4)]]===
 
Please see the main tool page for detailed info on this microscope: [[Deep UV Optical Microscope (Olympus)]]
 
Please see the main tool page for detailed info on this microscope: [[Deep UV Optical Microscope (Olympus)]]
 
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
 
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
Line 99: Line 100:
 
*Deep-UV Light source + DUV Camera
 
*Deep-UV Light source + DUV Camera
 
**DUV-100x sub-micron imaging/measurement
 
**DUV-100x sub-micron imaging/measurement
  +
  +
=== Microscope #7: [[Digital Microscope (Olympus DSX1000)|Olympus DSX1000 Digital Microscope (Bay 4)]] ===
  +
Please see the main tool page for detailed info on this microscope, click the link above.
  +
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Supervisor to get training.
  +
  +
*Motorized Stage + Objective Turret
  +
*Digital Viewing via Computer
  +
*Objectives: High-Res.: 5x, 50x // Long-Distance + Angled Viewing: 10x, 40x
  +
*Filters:
  +
**Bright Field
  +
**Dark Field
  +
**DIC/Nomarski
  +
*Native Olympus Software control & Camera
  +
**Calibrated measurements (calibrations locked)
  +
**Z (focus) measurement via motorized stage height
  +
**Rapidly capture multiple imaging modes
  +
**Offline Analysis Software available for free
  +
*Tilted Imaging capabilities, for deep (> few micron) features.
   
 
==[[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT Confocal Microscope (Bay 4)]]==
 
==[[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT Confocal Microscope (Bay 4)]]==
Line 118: Line 137:
 
*[[UCSB NanoFab Microscope Training|'''Microscope Training''']] - General procedures and info for using our microscopes
 
*[[UCSB NanoFab Microscope Training|'''Microscope Training''']] - General procedures and info for using our microscopes
   
*[//www.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Nikon Microscope Instruction Manual (Ecplise)]
+
*[//wiki.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Nikon Microscope Instruction Manual (Ecplise)]
*[//www.nanotech.ucsb.edu/wiki/images/2/28/Nikon-Microscope-OptiPhot-Manual.pdf Nikon Microscope Instruction Manual (Optiphot)]
+
*[//wiki.nanotech.ucsb.edu/wiki/images/2/28/Nikon-Microscope-OptiPhot-Manual.pdf Nikon Microscope Instruction Manual (Optiphot)]
 
*[https://www.amscope.com/software/AmScope/MU-Series-Complete-Manual-Complete.pdf AM Scope manual link].
 
*[https://www.amscope.com/software/AmScope/MU-Series-Complete-Manual-Complete.pdf AM Scope manual link].
 
*[https://www.amscope.com/software-download AM Scope Software link].
 
*[https://www.amscope.com/software-download AM Scope Software link].

Latest revision as of 11:35, 9 April 2021

Microscopes
Microscopes.jpg
Tool Type Inspection, Test and Characterization
Location Bay 3, 6 & 7
Supervisor Demis D. John
Supervisor Phone (805) 893-5934
Supervisor E-Mail demis@ucsb.edu
Description Optical Microscopes
Manufacturer Nikon & Olympus



Procedures & Tools

Microscope Training Guide

The guide linked above explains general usage info & the many advanced features available on most of our microscopes. New users are encouraged to read this, and also request in-person training by Demis.

Image Analysis Software

Many of our microscopes have cameras and software for image capture. If you know the microscope and objective used for acquiring a photo, you can make calibrated measurements on the photos at your own desktop using the following software:

Nikon

The Nikon scopes have 3rd party cameras that are connected to computers via AM Scope software which allows users to digitally capture images through the microscope and make calibrated measurements.

Microscope #2: Nikon Optiphot 200 (Bay 2)

  • Trinocular: Ocular Binoc. + Camera (Simultaneous)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
    • DIC only available on 100x and 150x mags due to image quality reduction at low mags due to DIC prisms which were removed for low mags.
  • Top Reflected Illumination (Episcopic)
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. Link here.

Microscope #3: Nikon Eclipse L200 (Bay 6)

  • Manual for Nikon Eclipse L200D
  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top Reflected Illumination (Episcopic)
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. Link here.

Microscope #4: Nikon Eclipse L200D (Bay 6)

  • Trinocular: Binoc. + Camera (Mutually Exclusive)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for desktop measurements. Link here.

Olympus

The lab has two general purpose Olympus microscopes, and two specialized microscopes that require training to use, although both of these can also be used for general imaging.

Photo of Microscope #01 in the Characterization lab, Room 1111
Microscope #01

Microscope #1: Olympus BHMJL (Bay 4)

  • Trinocular: Ocular Binoc. + Camera (Exclusive)
  • LED Illuminator, Variable
  • Objectives: 10x, 20x, 50x, 100x
  • Bright/Dark Field
  • Top Reflected (Episcopic) & Bottom Transmission (Diascopic) Illumination
  • AMScope 14MP Cameras with calibrated software for measurements. Software available for offline measurements: Link here.
  • User Manual: Olympus BHM Microscopes - Instruction Manual (PDF)

Microscope #5: Fluorescence Microscope: Olympus MX51 (Bay 6)

  • See the wiki page for the Olympus MX51 for full details
  • Trinocular: Binoc. + Camera (Simultaneous)
  • Native Olympus Stream Software:
    • Photo/video capture
    • Calibrated measurement (calibrations locked)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Filters: Green, ND
  • Bright/Dark Field
  • Differential Interference Contrast (DIC/Nomarski)
  • Top (Episcopic) & Bottom (Diascopic) Illumination
  • Three Fluorescence Filters (requires training, see main tool page for specs.)

Microscope #6: DUV Microscope: Olympus MX61A-DUV (Bay 4)

Please see the main tool page for detailed info on this microscope: Deep UV Optical Microscope (Olympus)

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
  • Motorized Stage + Objective Turret
  • Trinocular: Binoc. + Camera (Simultaneous)
  • Objectives: 5x, 10x, 20, 50x, 100x, DUV-100x
  • Filters: to be added
  • Native Olympus MX61 Software control & Camera
    • Calibrated measurements (calibrations locked)
    • Z (focus) measurement via motorized stage height
  • Deep-UV Light source + DUV Camera
    • DUV-100x sub-micron imaging/measurement

Microscope #7: Olympus DSX1000 Digital Microscope (Bay 4)

Please see the main tool page for detailed info on this microscope, click the link above.

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Supervisor to get training.
  • Motorized Stage + Objective Turret
  • Digital Viewing via Computer
  • Objectives: High-Res.: 5x, 50x // Long-Distance + Angled Viewing: 10x, 40x
  • Filters:
    • Bright Field
    • Dark Field
    • DIC/Nomarski
  • Native Olympus Software control & Camera
    • Calibrated measurements (calibrations locked)
    • Z (focus) measurement via motorized stage height
    • Rapidly capture multiple imaging modes
    • Offline Analysis Software available for free
  • Tilted Imaging capabilities, for deep (> few micron) features.

Olympus LEXT Confocal Microscope (Bay 4)

See the main tool page for complete info: Laser Scanning Confocal M-scope (Olympus LEXT)

YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
  • Motorized stage + Objective Turret
  • 100mm wafer stage
  • Native Olympus OLS2000 Software & Built-In Camera:
    • Calibrated measurement (calibrations locked)
    • Image stitching capabilities
  • 3D Laser-Scanning Confocal Microscopy capability:
    • 3D Topographical measurement (optical profilometry)
    • Surface roughness estimations (large roughness)
    • Thin-Film Film-Thickness Measurements (thicker films)

Procedures & Documentation