Difference between revisions of "Dry Etching Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Line 1: Line 1:
{| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible wikitable"
+
{| border="1" class="collapsible wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%"
 
|- bgcolor="#D0E7FF"
 
|- bgcolor="#D0E7FF"
 
! width="725" height="45" colspan="15" | <div style="font-size: 150%;">Dry Etching Recipes</div>
 
! width="725" height="45" colspan="15" | <div style="font-size: 150%;">Dry Etching Recipes</div>
Line 5: Line 5:
 
| <!-- INTENTIONALLY LEFT BLANK -->
 
| <!-- INTENTIONALLY LEFT BLANK -->
 
! width="300" bgcolor="#D0E7FF" align="center" height="35" colspan="4" | '''[[RIE Etching Recipes|RIE Etching]]'''
 
! width="300" bgcolor="#D0E7FF" align="center" height="35" colspan="4" | '''[[RIE Etching Recipes|RIE Etching]]'''
! width="300" bgcolor="#D0E7FF" align="center" colspan="5" | '''[[ICP Etching Recipes|ICP Etching]]'''
+
! width="300" bgcolor="#D0E7FF" align="center" colspan="4" | '''[[ICP Etching Recipes|ICP Etching]]'''
  +
! bgcolor="#D0E7FF" align="center" colspan="4"|'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
  +
! bgcolor="#D0E7FF" align="center"|'''[[Other Dry Etcher Recipes|Other Dry Etchers]]'''
 
|-
 
|-
 
! width="65" bgcolor="#D0E7FF" align="center" | '''Material'''
 
! width="65" bgcolor="#D0E7FF" align="center" | '''Material'''
Line 16: Line 18:
 
| width="120" bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic E640)]]
 
| width="120" bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic E640)]]
 
| width="85" bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]]
 
| width="85" bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]]
| width="85" bgcolor="#DAF1FF" |
+
| width="85" bgcolor="#DAF1FF" | [[Ashers (Technics PEII)|Ashers<br>(Technics PEII)]]
| width="85" bgcolor="#DAF1FF" |
+
| width="85" bgcolor="#DAF1FF" | [[Plasma Clean (Gasonics 2000)|Plasma Clean<br>(Gasonics 2000)]]
| width="85" bgcolor="#DAF1FF" |
+
| width="85" bgcolor="#DAF1FF" | [[UV Ozone Reactor]]
| width="85" bgcolor="#DAF1FF" |
+
| width="85" bgcolor="#DAF1FF" | [[Plasma Activation (EVG 810)|Plasma Activation<br>(EVG 810)]]
| width="85" bgcolor="#DAF1FF" |
+
| width="85" bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]]
 
|-
 
|-
 
! bgcolor="#D0E7FF" align="center" | Al
 
! bgcolor="#D0E7FF" align="center" | Al

Revision as of 13:53, 18 July 2012

Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 1
(Custom)
RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
Si Deep RIE
(PlasmaTherm/Bosch Etch)
ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Al
Ti
Cr
Ge
Ag
Ru
Mo
Ta
W
Al2O3
HfO2
ITo
SiO2
SiN
SiOxNy
Ta2O5
TiO2
TiN
ZnO2
ZrO2
GaAs
AlGaAs
InGaAlAs
InGaAsP
InP
GaN
AlGaN
AlN
GaN
AlGaN
AlN
GaSb
CdTe
ZnSe
Si
SiC
Sapphire