Difference between revisions of "Dry Etching Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
m (corrected links)
 
(171 intermediate revisions by 5 users not shown)
Line 1: Line 1:
  +
===<u>[[Process Group - Process Control Data#Etching .28Process Control Data.29|Process Control Data]]</u>===
{{Recipe Table Explanation}}
 
  +
<small>''See [[Process Group - Process Control Data#Etching .28Process Control Data.29|linked page]] for [https://en.wikipedia.org/wiki/Statistical_process_control process control data] (dep rate/stress etc. over time), for a selection of often-used thin-film depositions.''</small>
{| border="1" class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%"
 
  +
|- bgcolor="#D0E7FF"
 
  +
===Dry Etching Tools/Materials Table===
! width="725" height="45" colspan="15" | <div style="font-size: 150%;">Dry Etching Recipes</div>
 
  +
|- bgcolor="#D0E7FF"
 
  +
*<small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small>
| <!-- INTENTIONALLY LEFT BLANK -->
 
  +
*<small>'''A''': ''Material is available for use, but no recipes are provided.''</small>
! width="300" bgcolor="#D0E7FF" align="center" height="35" colspan="4" | '''[[RIE Etching Recipes|RIE Etching]]'''
 
  +
! width="300" bgcolor="#D0E7FF" align="center" colspan="4" | '''[[ICP Etching Recipes|ICP Etching]]'''
 
  +
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
! bgcolor="#D0E7FF" align="center" colspan="4"|'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
 
  +
|-
! bgcolor="#D0E7FF" align="center"|'''[[Other Dry Etcher Recipes|Other Dry Etchers]]'''
 
  +
! colspan="17" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div>
  +
|- bgcolor="#d0e7ff"
  +
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK -->
  +
! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]'''
  +
! colspan="6" |'''[[ICP Etching Recipes|ICP Etching]]'''
  +
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
  +
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
  +
|- bgcolor="#d0e7ff"
  +
! bgcolor="#d0e7ff" align="center" |'''Material'''
  +
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]
  +
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]]
  +
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 1 .28Panasonic E646V.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E646V)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
  +
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
  +
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
  +
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
  +
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]]
  +
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]]
  +
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]]
  +
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]]
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Ag
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |Al
  +
|
  +
|
  +
|[[RIE Etching Recipes|A]]
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}}
  +
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Au
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |Cr
  +
|
  +
|
  +
|A
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}}
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Cu
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |Ge
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Mo
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
 
|-
 
|-
  +
!Nb
! width="65" bgcolor="#D0E7FF" align="center" | '''Material'''
 
  +
|
| width="65" bgcolor="#DAF1FF" | [[RIE 1 (Custom)|RIE 1<br>(Custom)]]
 
  +
|
| width="65" bgcolor="#DAF1FF" | [[RIE 2 (MRC)|RIE 2<br> (MRC)]]
 
  +
|
| width="65" bgcolor="#DAF1FF" | [[RIE 3 (MRC)|RIE 3<br> (MRC)]]
 
  +
|
| width="100" bgcolor="#DAF1FF" | [[RIE 5 (PlasmaTherm)|RIE 5<br>(PlasmaTherm)]]
 
  +
|
| width="160" bgcolor="#DAF1FF" | [[Si Deep RIE (PlasmaTherm/Bosch Etch)|Si Deep RIE<br>(PlasmaTherm/Bosch Etch)]]
 
  +
|A
| width="120" bgcolor="#DAF1FF" | [[ICP Etch 1 (Panasonic E626I)|ICP Etch 1<br>(Panasonic E626I)]]
 
  +
|A
| width="120" bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic E640)]]
 
  +
|
| width="85" bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]]
 
  +
|
| width="85" bgcolor="#DAF1FF" | [[Ashers (Technics PEII)|Ashers<br>(Technics PEII)]]
 
  +
|
| width="95" bgcolor="#DAF1FF" | [[Plasma Clean (Gasonics 2000)|Plasma Clean<br>(Gasonics 2000)]]
 
  +
|
| width="85" bgcolor="#DAF1FF" | [[UV Ozone Reactor]]
 
  +
|
| width="85" bgcolor="#DAF1FF" | [[Plasma Activation (EVG 810)|Plasma Activation<br>(EVG 810)]]
 
  +
|
| width="85" bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]]
 
  +
|
|-bgcolor ="#EEFFFF"
 
  +
|
! bgcolor="#D0E7FF" align="center" | Al
 
|
+
|
  +
|- bgcolor="#ffffff"
|
 
  +
! bgcolor="#d0e7ff" align="center" |Ni
|
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
 
|-
 
|-
  +
!Os
! bgcolor="#D0E7FF" align="center" | Ti
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|A
|
+
|A
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
  +
|
|-bgcolor ="#EEFFFF"
 
  +
|
! bgcolor="#D0E7FF" align="center" | Cr
 
|
+
|
  +
|- bgcolor="#eeffff"
|
 
  +
! bgcolor="#d0e7ff" align="center" |Pt
|
 
| A
+
|
|
+
|
  +
|
| {{rl|ICP Etching Recipes|CrEtch(Panasonic 1)}}
 
| A
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |Ru
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|{{Rl|ICP Etching Recipes|Ru (Ruthenium) Etch (Panasonic 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Si
  +
|
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)}}
  +
|{{Rl|ICP Etching Recipes|Si_Etching_.28Fluorine_ICP_Etcher.29}}
  +
|
  +
|
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}}
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |Ta
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Ti
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}}
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub>
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R]
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub>
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}}
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |AlGaAs
  +
|
  +
|
  +
|{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}}
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}}
  +
|
  +
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]]
  +
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |AlGaN
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]]
  +
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |AlN
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
 
|-
 
|-
  +
!BCB
! bgcolor="#D0E7FF" align="center" | Ge
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|A
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
  +
|
|-bgcolor ="#EEFFFF"
 
  +
|
! bgcolor="#D0E7FF" align="center" | Ag
 
|
+
|
  +
|- bgcolor="#eeffff"
|
 
  +
! bgcolor="#d0e7ff" align="center" |CdZnTe
|
 
  +
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}}
|
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|-
+
|
  +
|
! bgcolor="#D0E7FF" align="center" | Ru
 
|
+
|
|
+
|
|
+
|
|
+
|A
  +
|- bgcolor="#ffffff"
|
 
  +
! bgcolor="#d0e7ff" align="center" |GaAs
|
 
|
+
|
|
+
|
  +
|{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}}
|
 
|
+
|
|
+
|
  +
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}}
|
 
  +
|{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}}
|
 
  +
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]]
|-bgcolor ="#EEFFFF"
 
  +
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}}
! bgcolor="#D0E7FF" align="center" | Mo
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|A
  +
|- bgcolor="#eeffff"
|
 
  +
! bgcolor="#d0e7ff" align="center" |GaN
|
 
|
+
|
|
+
|
  +
|{{rl|RIE Etching Recipes|GaN Etching (RIE 5)}}
|
 
|
+
|
|-
+
|
  +
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}}
! bgcolor="#D0E7FF" align="center" | Ta
 
|
+
|A
  +
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]]
|
 
  +
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
|
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|A
  +
|- bgcolor="#ffffff"
|
 
  +
! bgcolor="#d0e7ff" align="center" |GaSb
|
 
|
+
|
  +
|
|-bgcolor ="#EEFFFF"
 
  +
|
! bgcolor="#D0E7FF" align="center" | W
 
|
+
|
|
+
|
|
+
|A
|
+
|A
|
+
|A
  +
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}}
|
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub>
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |InGaAlAs
  +
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |InGaAsP
  +
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
  +
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |InP
  +
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|A
  +
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
  +
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |ITO
  +
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
 
|-
 
|-
  +
!LiNbO3
! bgcolor="#D0E7FF" align="center" | Al<sub>2</sub>O<sub>3</sub>
 
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
|
+
|
  +
|
|-bgcolor ="#EEFFFF"
 
  +
|
! bgcolor="#D0E7FF" align="center" | HfO<sub>2</sub>
 
|
+
|A
  +
|- bgcolor="#ffffff"
|
 
  +
!Photoresist
|
 
  +
& ARC
|
 
|
+
|
|
+
|A
  +
|[https://wiki.nanotech.ucsb.edu/wiki/RIE_Etching_Recipes#Photoresist_and_ARC_.28RIE_5.29 R]
|
 
|
+
|
  +
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_.26_ARC_.28Fluorine_ICP_Etcher.29 R]
|
 
  +
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R]
|
 
  +
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_etching_.28Panasonic_2.29 R]
|
 
|
+
|
|
+
|
  +
|[[Oxygen Plasma System Recipes#O2 Ashing|R]]
|-
 
  +
|[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|R]]
! bgcolor="#D0E7FF" align="center" | ITo
 
|
+
|
|
+
|
|
+
|
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | SiO<sub>2</sub>
 
|
 
|
 
|
 
|
 
|
 
| {{rl|ICP Etching Recipes|SIO2Etch(Panasonic 1)}}
 
| {{rl|ICP Etching Recipes|SIO2Etch(Panasonic 2)}}
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | SiN
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | SiOxNy
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | Ta<sub>2</sub>O<sub>5</sub>
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | TiO<sub>2</sub>
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | TiN
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | ZnO<sub>2</sub>
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | ZrO<sub>2</sub>
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | GaAs
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | AlGaAs
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | InGaAlAs
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | InGaAsP
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | InP
 
|
 
| {{rl|RIE2 Etching Recipes|InP Etch (MRC)}}
 
|
 
|
 
|
 
|
 
|
 
| {{rl|ICP Etching Recipes|InP Etch (Unaxis VLR)}}
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | GaN
 
|
 
|
 
|
 
|
 
|
 
| {{rl|GaN Etching Recipes|GaN Etch (Unaxis VLR)}}
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | AlGaN
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | AlN
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | GaN
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | AlGaN
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | AlN
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | GaSb
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | CdTe
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-
 
! bgcolor="#D0E7FF" align="center" | ZnSe
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | Si
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
 
|
 
|
  +
|A
{{rl|ICP Etching Recipes|InP Etch (Unaxis VLR)}}
 
 
|-
 
|-
  +
!Ru
! bgcolor="#D0E7FF" align="center" | SiC
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|-bgcolor ="#EEFFFF"
 
! bgcolor="#D0E7FF" align="center" | Sapphire
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
|
 
 
|
 
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R]]
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |SiC
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}}
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |SiN
  +
|
  +
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}}
  +
|
  +
|
  +
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R]]
  +
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}}
  +
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 2)}}
  +
|
  +
|
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub>
  +
|
  +
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}}
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|SiO2 Etching (Fluorine ICP Etcher)}}
  +
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}}
  +
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}}
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |SiOxNy
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
 
|-
 
|-
  +
!SU8
! bgcolor="#D0E7FF" align="center" | '''Material'''
 
  +
|
| bgcolor="#DAF1FF" | [[RIE 1 (Custom)|RIE 1<br>(Custom)]]
 
  +
|
| bgcolor="#DAF1FF" | [[RIE 2 (MRC)|RIE 2<br> (MRC)]]
 
  +
|
| bgcolor="#DAF1FF" | [[RIE 3 (MRC)|RIE 3<br> (MRC)]]
 
  +
|
| bgcolor="#DAF1FF" | [[RIE 5 (PlasmaTherm)|RIE 5<br>(PlasmaTherm)]]
 
  +
|
| bgcolor="#DAF1FF" | [[Si Deep RIE (PlasmaTherm/Bosch Etch)|Si Deep RIE<br>(PlasmaTherm/Bosch Etch)]]
 
  +
|A
| bgcolor="#DAF1FF" | [[ICP Etch 1 (Panasonic E626I)|ICP Etch 1<br>(Panasonic E626I)]]
 
  +
|
| bgcolor="#DAF1FF" | [[ICP Etch 2 (Panasonic E640)|ICP Etch 2<br>(Panasonic E640)]]
 
  +
|
| bgcolor="#DAF1FF" | [[ICP-Etch (Unaxis VLR)|ICP-Etch<br>(Unaxis VLR)]]
 
  +
|
| bgcolor="#DAF1FF" | [[Ashers (Technics PEII)|Ashers<br>(Technics PEII)]]
 
  +
|
| bgcolor="#DAF1FF" | [[Plasma Clean (Gasonics 2000)|Plasma Clean<br>(Gasonics 2000)]]
 
  +
|
| bgcolor="#DAF1FF" | [[UV Ozone Reactor]]
 
  +
|
| bgcolor="#DAF1FF" | [[Plasma Activation (EVG 810)|Plasma Activation<br>(EVG 810)]]
 
  +
|
| bgcolor="#DAF1FF" | [[XeF2 Etch (Xetch)|XeF2 Etch<br>(Xetch)]]
 
  +
|
  +
|
  +
|
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A]
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |TiN
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub>
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |W-TiW
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}}
  +
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub>
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |ZnS
  +
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |ZnSe
  +
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#ffffff"
  +
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|- bgcolor="#eeffff"
  +
! bgcolor="#d0e7ff" align="center" |'''Material'''
  +
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]
  +
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]]
  +
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E626I)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]]
  +
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
  +
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
  +
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
  +
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
  +
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]]
  +
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]]
  +
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]]
  +
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]]
 
|}
 
|}
  +
  +
[[Category:Processing]]

Latest revision as of 15:31, 7 February 2024

Process Control Data

See linked page for process control data (dep rate/stress etc. over time), for a selection of often-used thin-film depositions.

Dry Etching Tools/Materials Table

  • R: Recipe is available. Clicking this link will take you to the recipe.
  • A: Material is available for use, but no recipes are provided.
Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E646V)
ICP Etch 2
(Panasonic E626I)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)
Ag A
Al A R R A
Au R
Cr A R A A
Cu A
Ge A A A A
Mo A
Nb A A
Ni R
Os A A
Pt R
Ru A R A
Si R R A R A
Ta A A A
Ti R A A
Al2O3 A R A
Al2O3 (Sapphire) R A A
AlGaAs R R R R A
AlGaN R R A
AlN R A
BCB A
CdZnTe R A
GaAs R R R R R A
GaN R R A R R A
GaSb A A A R A
HfO2 A
InGaAlAs R A R A
InGaAsP R R R A
InP R A A R R R
ITO R A
LiNbO3 A
Photoresist

& ARC

A R R R R R R A
Ru A R
SiC R A A
SiN R R R R A A
SiO2 R R R R R A
SiOxNy A A A
SU8 A
Ta2O5 A A A
TiN A
TiO2 A
W-TiW R A A
ZnO2 A
ZnS R A
ZnSe R A
ZrO2 A
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)