Difference between revisions of "Deep UV Optical Microscope (Olympus)"
Jump to navigation
Jump to search
m (added model field) |
|||
(6 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ |
+ | {{tool2|{{PAGENAME}} |
|picture=UVOlympus.jpg |
|picture=UVOlympus.jpg |
||
|type = Inspection, Test and Characterization |
|type = Inspection, Test and Characterization |
||
|super= Tony Bosch |
|super= Tony Bosch |
||
+ | |super2= Demis D. John |
||
|location=Bay 7 |
|location=Bay 7 |
||
− | |description = |
+ | |description = Deep-Ultraviolet (250nm) Microscope |
|manufacturer = Olympus |
|manufacturer = Olympus |
||
|materials = |
|materials = |
||
Line 10: | Line 11: | ||
|model= MX61A-DUV |
|model= MX61A-DUV |
||
}} |
}} |
||
+ | '''DUV Camera is non-operational and unable to be repaired. Visible camera is still functional. 2022-02''' |
||
⚫ | |||
+ | |||
⚫ | This system does general purpose imaging in the visible and also has high resolution/high magnification DUV imaging using |
||
⚫ | |||
⚫ | |||
+ | |||
+ | The system has precision motorized stage control and is fully computer controlled for image capture and sample manipulation. |
||
+ | |||
+ | A Good system for CD measurements on wafer (250nm and above) without entry into the SEM. |
||
+ | |||
+ | ==Detailed Specifications== |
||
+ | |||
+ | *Microscope Objectives: |
||
+ | **5x, 10x, 20x, 50x, 100x, DUV-100x |
||
+ | *Software Control: |
||
+ | **Motorized Stage & Objective Turret |
||
+ | **Calibrated Measurements (calibrations fixed) |
||
+ | **Z-motor (focus height) measurement |
||
+ | *Filters: |
||
+ | **Bright Field / Dark Field (visible only) |
||
+ | |||
+ | ==Examples== |
||
+ | [[File:Olympus MX61A-DUV res test 100x DUV v1.png|alt=DUV microscope image with 1µm scale bar|none|thumb|504x504px|100x DUV image taken with the Olympus MX61A-DUV, showing sub-micron resolution.]] |
||
+ | |||
+ | ==Other Info== |
||
+ | '''''Equip > Characterization > <u>[[Microscopes]]</u>''''' - ''see a list of all our microscopes'' |
Latest revision as of 07:24, 31 August 2022
|
DUV Camera is non-operational and unable to be repaired. Visible camera is still functional. 2022-02
About
This system does general purpose imaging in the visible and also has high resolution/high magnification DUV imaging using 250 nm light. Surface features less than 100nm can be resolved.
The system has precision motorized stage control and is fully computer controlled for image capture and sample manipulation.
A Good system for CD measurements on wafer (250nm and above) without entry into the SEM.
Detailed Specifications
- Microscope Objectives:
- 5x, 10x, 20x, 50x, 100x, DUV-100x
- Software Control:
- Motorized Stage & Objective Turret
- Calibrated Measurements (calibrations fixed)
- Z-motor (focus height) measurement
- Filters:
- Bright Field / Dark Field (visible only)
Examples
Other Info
Equip > Characterization > Microscopes - see a list of all our microscopes