User contributions
Jump to navigation
Jump to search
- 15:44, 8 October 2018 diff hist +42 N Test Data of etching SiO2 with CHF3/CF4/O2 add data file Tag: Visual edit
- 15:42, 8 October 2018 diff hist +48 ICP Etching Recipes →SiO2 Etching (Panasonic 2): adding SiO2 etch test title Tag: Visual edit
- 15:36, 8 October 2018 diff hist +4 ICP Etching Recipes →ICP Etch 1 (Panasonic E626I): add SiO2 test data Tag: Visual edit
- 15:32, 8 October 2018 diff hist +79 ICP Etching Recipes →SiO2 Etching (Panasonic 1): adding test data Tag: Visual edit
- 15:28, 8 October 2018 diff hist 0 N File:SiO2 Etch using ICP2 with O2.pdf
- 11:24, 4 October 2018 diff hist -93 InP Etch Test Result in Details adding a data file Tag: Visual edit
- 11:19, 4 October 2018 diff hist 0 InP Etch Test Result in Details add a new data file Tag: Visual edit
- 11:12, 4 October 2018 diff hist +23 InP Etch Rate and Selectivity (InP/SiO2) add a new pic Tag: Visual edit
- 10:59, 4 October 2018 diff hist +36 InP Etch Rate and Selectivity (InP/SiO2) add data Tag: Visual edit
- 09:02, 21 August 2018 diff hist +30 Lithography Recipes →Holography Recipes
- 16:12, 16 August 2018 diff hist +64 Lithography Recipes →Holography Recipes
- 16:03, 16 August 2018 diff hist -64 Lithography Recipes →Holography Recipes
- 15:17, 13 August 2018 diff hist +93 InP Etch Test Result in Details add a new data file Tag: Visual edit
- 15:01, 13 August 2018 diff hist +63 InP Etch Rate and Selectivity (InP/SiO2) add a pic Tag: Visual edit
- 14:58, 13 August 2018 diff hist -91 InP Etch Rate and Selectivity (InP/SiO2) add data Tag: Visual edit
- 14:03, 2 July 2018 diff hist +1 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 14:02, 2 July 2018 diff hist +45 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 14:02, 2 July 2018 diff hist 0 N File:SiO2-Mask Etch Recipe for Unaxis Cl2 Etch.pdf current
- 14:01, 2 July 2018 diff hist +82 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR)
- 15:36, 29 June 2018 diff hist -129 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 15:35, 29 June 2018 diff hist -1 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 15:34, 29 June 2018 diff hist -93 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 15:32, 29 June 2018 diff hist -100 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 15:32, 29 June 2018 diff hist -123 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 15:10, 12 June 2018 diff hist +16 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V) Tag: Visual edit
- 15:06, 12 June 2018 diff hist +3 Sputtering Recipes →Sputter 5 (AJA ATC 2200-V) Tag: Visual edit
- 15:05, 12 June 2018 diff hist +71 Sputtering Recipes →Sputter 4 (AJA ATC 2200-V): adding Cu deposition (Sputter4) into WiKi Tag: Visual edit
- 15:01, 12 June 2018 diff hist +84 Sputtering Recipes adding Al deposition data (Sputter5) into WiKi Tag: Visual edit
- 14:13, 29 May 2018 diff hist +65 InP Etch Rate and Selectivity (InP/SiO2) add a pic Tag: Visual edit
- 14:04, 29 May 2018 diff hist +35 InP Etch Rate and Selectivity (InP/SiO2) add data Tag: Visual edit
- 08:33, 18 May 2018 diff hist +55 Lithography Recipes →Photolithography Recipes
- 08:32, 18 May 2018 diff hist +55 Lithography Recipes →Photolithography Recipes
- 08:27, 18 May 2018 diff hist +230 Contact Alignment Recipes
- 08:25, 18 May 2018 diff hist 0 Contact Alignment Recipes
- 08:23, 18 May 2018 diff hist +36 Contact Alignment Recipes
- 08:21, 18 May 2018 diff hist +65 Contact Alignment Recipes
- 08:18, 18 May 2018 diff hist +126 Contact Alignment Recipes
- 08:13, 18 May 2018 diff hist 0 Lithography Recipes →Photolithography Recipes: adding recipe Tag: Visual edit
- 11:05, 2 May 2018 diff hist 0 InP Etch Rate and Selectivity (InP/SiO2) Tag: Visual edit
- 11:05, 2 May 2018 diff hist +711 InP Etch Rate and Selectivity (InP/SiO2) Tag: Visual edit
- 10:38, 2 May 2018 diff hist 0 InP Etch Rate and Selectivity (InP/SiO2) Tag: Visual edit
- 10:32, 2 May 2018 diff hist +22 InP Etch Rate and Selectivity (InP/SiO2) Tag: Visual edit
- 08:57, 2 May 2018 diff hist -46 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 08:57, 2 May 2018 diff hist +7 N InP Etch Test-in details Created page with "details" current Tag: Visual edit
- 08:55, 2 May 2018 diff hist +46 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 08:48, 2 May 2018 diff hist +90 N InP Etch Test Result in Details Created page with "https://www.nanotech.ucsb.edu/wiki/index.php/File:InP_Etch_using_Unaxis_PM1_at_200_C-2.pdf" Tag: Visual edit
- 08:47, 2 May 2018 diff hist +36 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 08:45, 2 May 2018 diff hist -31 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 08:43, 2 May 2018 diff hist -44 ICP Etching Recipes →InP-InGaAs-InAlAs Etch (Unaxis VLR) Tag: Visual edit
- 08:43, 2 May 2018 diff hist +7 N InP Etch test -details Created page with "details" current Tag: Visual edit