User contributions
Jump to navigation
Jump to search
- 15:53, 31 May 2024 diff hist -3 Template:Tool2 Remove "N/A" when "recipes" section is not shown current
- 15:48, 31 May 2024 diff hist 0 File:DSEiii Example Bosch Etch 02.jpg John d uploaded a new version of File:DSEiii Example Bosch Etch 02.jpg current
- 15:46, 31 May 2024 diff hist +615 DSEIII (PlasmaTherm/Deep Silicon Etcher) added beter Bosch example showing striations current Tag: Visual edit
- 15:44, 31 May 2024 diff hist +133 N File:DSEiii Example Bosch Etch 02.jpg
- 10:22, 29 May 2024 diff hist -435 Template:Announcements removed old ASML annc, fixed sig on new ASMl annc
- 21:28, 15 May 2024 diff hist +429 Calculators + Utilities →Fabrication Processes & Converters: link to example Trello board current Tag: Visual edit
- 17:17, 15 May 2024 diff hist +273 Direct-Write Lithography Recipes added links to CAD design tips current Tag: Visual edit
- 13:23, 15 May 2024 diff hist +355 Oxygen Plasma System Recipes →SiN Etching: PR backside protect current Tag: Visual edit
- 20:37, 13 May 2024 diff hist +183 Frequently Asked Questions →I can't connect to the Nanofiles FTP server!: updated Cyberduck prefs current Tag: Visual edit
- 12:37, 9 May 2024 diff hist 0 m Lithography Recipes →Photolithography Recipes: fixed link current Tag: Visual edit
- 12:49, 7 May 2024 diff hist +62 ICP Etching Recipes →High Rate Bosch Etch (DSEIII): added to increase EtchA time current Tag: Visual edit
- 13:08, 3 May 2024 diff hist +1 m Stepper 3 (ASML DUV) →Operating Procedures current Tag: Visual edit
- 13:07, 3 May 2024 diff hist -884 Stepper 3 (ASML DUV) →Operating Procedures: deleted links to video training, point instead to gDrive doc (access-restricted). Tag: Visual edit
- 12:59, 3 May 2024 diff hist +268 Stepper 3 (ASML DUV) →Operating Procedures: updates to wording Tag: Visual edit
- 11:18, 1 May 2024 diff hist +191 Packaging Recipes →Wax-Mounting to Carrier: moved procedure into table current Tag: Visual edit
- 09:35, 1 May 2024 diff hist +100 ASML Stepper 3 - UCSB Test Reticles →Resolution Test Charts: added polarity current Tag: Visual edit
- 08:57, 1 May 2024 diff hist +155 KLayout Design Tips →How to draw Text: minor update current Tag: Visual edit