+ | =====EBeam4 Update - Still down===== |
||
− | <!--feedBurner name="UCSBNanofab-Announcements" /--> |
||
+ | EBeam4 will remain down overnight. |
||
− | <!-- Description of the RSS feed --> |
||
− | '''''Important Announcements''''' |
||
⚫ | |||
− | <!-- |
||
⚫ | |||
+ | The new motor arrived as well as the new junction box and new cables. |
||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
+ | I removed the old junction box/plugs due to a lot of corrosion inside the box caused by it being located directly under the water supply lines. |
||
− | ===== Plating Bench: Down 6/7 9a-12n ===== |
||
− | The plating bench in Bay 4 will be unavailable on Wednesday, 6/7/22 from 9am-noon. Please plan accordingly. |
||
⚫ | |||
+ | This corrosion inside the box could have contributed to the failure of the old motor. |
||
− | ===== Masks Mandatory: May 27-June 12 ===== |
||
− | UCSB has reinstituted a mandatory mask mandate for all indoor spaces on campus. |
||
+ | I installed the new motor, ran all new cables to the new junction box in it's new location away from the water lines. |
||
− | The mandate begins May 27, and extends through June 12. |
||
+ | I was able to test the function of the hoist by raising and lowering the bell jar while in manual mode. |
||
− | See the [https://info.ia.ucsb.edu/message/4luhko/0equghb full announcement at this link]. |
||
+ | For safety reasons, I had the machine powered off during the duration of the work being done, so the cryo will be in regen overnight. |
||
− | We will provide masks at the metal table in front of the cleanroom entry. |
||
+ | Tomorrow morning I will continue testing the system to ensure everything is working properly before I release the tool. |
||
− | See the full policies at '''[[COVID-19_User_Policies]]''' |
||
⚫ | |||
+ | I will send another email when an update is available. |
||
⚫ | |||
− | Deuterated Silane (SiD4) is out. Bottle delivery delayed from vendor - see email for updates. |
||
⚫ | |||
+ | //10:36, 30 May 2024 (PDT) |
||
⚫ | |||
− | Effective Dec.1, 2021, all of our electron beam lithography rates are lowered. The new rates are as follows: |
||
+ | =====Stepper #3 (ASML DUV) - System UP and calibrated===== |
||
− | Industrial Users: $405/hour |
||
+ | We have finished calibrations, |
||
+ | System is up. |
||
+ | Reminder to check/recalibrate your exposure dose. Focus should be the same, but beam optics changeout will affect dose. |
||
− | UC Academic Users: $126/hour |
||
⚫ | |||
− | Non-UC Academic Users: $150/hour |
||
+ | =====Atomic Force Microscope (Dimension ICON) - 05/17: System UP===== |
||
− | UCSB CNSI Incubator USers: $260/hour |
||
+ | Head was repaired and returned today. A quick test showed correct performance. Note also that the pin board has been repaired so all 4 pins are now present. Lets keep it that way so please be careful when loading the tip holder! |
||
− | //[[User: |
+ | //[[User:Mehalana v|Vraj Mehalana]] 13:46, 20 May 2024 (PDT) |
+ | =====MA6 TSA is down - Update===== |
||
− | <!---------- end of Equipment Status ------------> |
||
+ | We have received the replacement motor for the TSA Y axis. The FSE will be onsite Monday June 3rd to work on the tool. |
||
− | <!----------------------------------------------> |
||
⚫ | |||
⚫ | |||
− | <!-------------------------------------------- |
||
+ | The tool remains up for backside alignment and topside exposures that do not require alignment. |
||
+ | -Lee |
||
+ | //15:59, 22 May 2024 (PDT) |
||
+ | =====Velion FIB Tool DOWN===== |
||
+ | Raith service are installing and aligning a new GaBiLi source. The Velion FIB column is not available to users until further notice. |
||
⚫ | |||
− | ====== HOW TO ADD NEWS ITEMS ====== |
||
⚫ | |||
+ | The board we were waiting on arrived, but it did not resolve the tool issue. We are working with Panasonic on the next steps. |
||
+ | //[[User:Mehalana v|Vraj Mehalana]] 14:17, 1 March 2024 (PST) |
||
+ | |||
+ | =====Lab Access Changes: Symmetry App===== |
||
+ | The iris scanner has been decommissioned. Please use the card reader which supports: |
||
+ | |||
+ | -Physical card |
||
+ | |||
+ | -Mobile phone via Symmetry App |
||
+ | |||
+ | //10:54, 23 May 2024 (PDT) |
||
+ | |||
+ | =====Wafer Bonder, (Suss SB6-8E)===== |
||
+ | SUSS aims to be on site in early February. We’ll will send out an email once I get confirmation for a specific date. |
||
+ | //[[User:Mehalana v|Vraj Mehalana]] 14:23, 13 December 2023 (PST) |
||
+ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
⚫ | |||
* You can copy/paste the example below for a new news item. |
* You can copy/paste the example below for a new news item. |
||
* Use level 5 heading for each item (5 equal signs surrounding the title) - they will show up as separate RSS items this way. (This looks best on the Wiki homepage) |
* Use level 5 heading for each item (5 equal signs surrounding the title) - they will show up as separate RSS items this way. (This looks best on the Wiki homepage) |
||
− | * You must add a user signature at the end of each post via four tildes: |
+ | * You must add a user signature at the end of each post via four tildes: [[User:Silva|Silva]] 13:26, 4 February 2023 (PST). Required for the RSS plugin to determine the timestamp, or else post goes to the end of the RSS feed. |
* Use double-slash: // at start of new lines - makes display on the Samsung Display look a lot better, since it strips newlines. |
* Use double-slash: // at start of new lines - makes display on the Samsung Display look a lot better, since it strips newlines. |
||
* Optional: After saving the page, delete the name after the two dashes "--" and delete the "[[(talk)...]]" link. |
* Optional: After saving the page, delete the name after the two dashes "--" and delete the "[[(talk)...]]" link. |
||
Line 73: | Line 90: | ||
===== NanoFab making LN2 icecream ===== |
===== NanoFab making LN2 icecream ===== |
||
Tomorrow the NanoFab will be serving liquid nitrogen ice cream. |
Tomorrow the NanoFab will be serving liquid nitrogen ice cream. |
||
⚫ | |||
− | // ~~~~ |
||
************* (end of example) ************** |
************* (end of example) ************** |
||
− | The |
+ | The [[User:Silva|Silva]] 13:26, 4 February 2023 (PST) will be replaced with your username & timestamp after you submit the post. |
----------------------------------------------> |
----------------------------------------------> |
Latest revision as of 10:36, 30 May 2024
EBeam4 Update - Still down
EBeam4 will remain down overnight.
The new motor arrived as well as the new junction box and new cables.
I removed the old junction box/plugs due to a lot of corrosion inside the box caused by it being located directly under the water supply lines.
This corrosion inside the box could have contributed to the failure of the old motor.
I installed the new motor, ran all new cables to the new junction box in it's new location away from the water lines.
I was able to test the function of the hoist by raising and lowering the bell jar while in manual mode.
For safety reasons, I had the machine powered off during the duration of the work being done, so the cryo will be in regen overnight.
Tomorrow morning I will continue testing the system to ensure everything is working properly before I release the tool.
I will send another email when an update is available.
//10:36, 30 May 2024 (PDT)
Stepper #3 (ASML DUV) - System UP and calibrated
We have finished calibrations, System is up.
Reminder to check/recalibrate your exposure dose. Focus should be the same, but beam optics changeout will affect dose.
//Vraj Mehalana 11:17, 24 May 2024 (PDT)
Atomic Force Microscope (Dimension ICON) - 05/17: System UP
Head was repaired and returned today. A quick test showed correct performance. Note also that the pin board has been repaired so all 4 pins are now present. Lets keep it that way so please be careful when loading the tip holder!
//Vraj Mehalana 13:46, 20 May 2024 (PDT)
MA6 TSA is down - Update
We have received the replacement motor for the TSA Y axis. The FSE will be onsite Monday June 3rd to work on the tool.
The tool remains up for backside alignment and topside exposures that do not require alignment.
-Lee //15:59, 22 May 2024 (PDT)
Velion FIB Tool DOWN
Raith service are installing and aligning a new GaBiLi source. The Velion FIB column is not available to users until further notice.
//Vraj Mehalana 10:58, 30 April 2024 (PDT)
ICP1 Down
The board we were waiting on arrived, but it did not resolve the tool issue. We are working with Panasonic on the next steps. //Vraj Mehalana 14:17, 1 March 2024 (PST)
Lab Access Changes: Symmetry App
The iris scanner has been decommissioned. Please use the card reader which supports:
-Physical card
-Mobile phone via Symmetry App
//10:54, 23 May 2024 (PDT)
Wafer Bonder, (Suss SB6-8E)
SUSS aims to be on site in early February. We’ll will send out an email once I get confirmation for a specific date. //Vraj Mehalana 14:23, 13 December 2023 (PST)