Difference between revisions of "YES-150C-Various-Resists"
Jump to navigation
Jump to search
m (description) |
(link to PR datasheets) |
||
(One intermediate revision by the same user not shown) | |||
Line 3: | Line 3: | ||
Once pressure flattens etching is complete. |
Once pressure flattens etching is complete. |
||
− | There is uncertainty in the exact completion time, somewhere between the peak pressure and the point where it goes flat. Using known PR thicknesses you can estimate etch rate from these plots. |
+ | There is uncertainty in the exact completion time, somewhere between the peak pressure and the point where it goes flat. Using known PR thicknesses (spun at standard spin speeds - see the [https://www.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#PositivePR datasheets]) you can estimate etch rate from these plots. |
[[File:YES150CResists.jpg|660x660px]] |
[[File:YES150CResists.jpg|660x660px]] |
Revision as of 09:46, 25 September 2019
Pressure drop indicates completion of etch.
Once pressure flattens etching is complete.
There is uncertainty in the exact completion time, somewhere between the peak pressure and the point where it goes flat. Using known PR thicknesses (spun at standard spin speeds - see the datasheets) you can estimate etch rate from these plots.