Difference between revisions of "Vacuum Deposition Recipes"
Jump to navigation
Jump to search
m (→Process Control Data: smaller font) |
|||
(211 intermediate revisions by 8 users not shown) | |||
Line 1: | Line 1: | ||
+ | ===[[Process Group - Process Control Data#Deposition .28Process Control Data.29|<u>Process Control Data</u>]]=== |
||
− | This table can be used to help located the needed recipe. |
||
+ | <small>''See [[Process Group - Process Control Data#Deposition .28Process Control Data.29|linked page]] for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.''</small> |
||
+ | ===Deposition Tools/Materials Table=== |
||
− | {| border="1" class="collapsible wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" |
||
+ | |||
− | |-bgcolor="#D0E7FF" |
||
+ | *<small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small> |
||
− | ! colspan=18 height=45 width=1575|<div style="font-size: 150%;">Vacuum Deposition Recipes</div> |
||
+ | *<small>'''A''': ''Material is available for use, but no recipes are provided.''</small> |
||
− | |- bgcolor="#D0E7FF" |
||
+ | |||
− | | <!-- INTENTIONALLY LEFT BLANK --> <br> |
||
+ | {| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1" |
||
− | ! bgcolor="#D0E7FF" align="center" colspan="4" | '''E-Beam Evaporation''' |
||
+ | |- bgcolor="#d0e7ff" |
||
− | ! bgcolor="#D0E7FF" align="center" colspan="5" | '''Sputtering''' |
||
+ | ! colspan="16" width="1675" height="45" |<div style="font-size: 150%;">Vacuum Deposition Recipes</div> |
||
− | ! bgcolor="#D0E7FF" align="center" colspan="2" | '''Thermal Evaporation''' |
||
+ | |- bgcolor="#d0e7ff" |
||
− | ! bgcolor="#D0E7FF" align="center" colspan="3" | '''Plasma Enhanced Chemical<br>Vapor Deposition (PECVD)''' |
||
+ | |<!-- INTENTIONALLY LEFT BLANK --><br> |
||
− | ! width="90" bgcolor="#D0E7FF" align="center" | '''Atomic Layer Deposition''' |
||
− | ! |
+ | ! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[E-Beam Evaporation Recipes|E-Beam Evaporation]]''' |
+ | ! colspan="4" |'''[[Sputtering Recipes|Sputtering]]''' |
||
− | ! width="100" bgcolor="#D0E7FF" align="center" | '''Molecular Vapor Deposition''' |
||
+ | ! colspan="2" bgcolor="#d0e7ff" align="center" |'''[[Thermal Evaporation Recipes|Thermal Evaporation]]''' |
||
+ | ! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[PECVD Recipes|Plasma Enhanced Chemical<br>Vapor Deposition (PECVD)]]''' |
||
+ | ! width="90" bgcolor="#d0e7ff" align="center" |'''[[Atomic Layer Deposition Recipes|Atomic Layer Deposition]]''' |
||
+ | ! width="80" bgcolor="#d0e7ff" align="center" |'''[[Molecular Vapor Deposition Recipes|Molecular Vapor Deposition]]''' |
||
|- |
|- |
||
− | ! width=" |
+ | ! width="20" bgcolor="#d0e7ff" align="center" |'''Material''' |
− | | width="65" |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]] |
− | | width="65" |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]] |
− | | width="65" |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]] |
− | | width="65" |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]] |
− | | width="65" |
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29|Sputter 3<br>(AJA ATC 2000-F)]] |
− | | width=" |
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(AJA ATC 2200-V)]] |
+ | | width="65" bgcolor="#daf1ff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_5_.28AJA_ATC_2200-V.29 Sputter 5 (AJA ATC 2200-V)] |
||
− | | width="65" | [[Sputter 3]] |
||
+ | | width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]] |
||
− | | width="65" | [[Sputter 4]] |
||
+ | | width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]] |
||
− | | width="85" | [[Sputter 5 (Lesker AXXIS)]] |
||
− | | width="65" |
+ | | width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]] |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]] |
||
− | | width="65" | [[Thermal 2]] |
||
− | | width=" |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]] |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]] |
||
− | | width="115" | [[PECVD 2 (Advanced Vacuum)|PECVD 2<br>(Advanced Vacuum)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAL)]] |
||
− | | width="75" | [[Unaxis VLR ICP-PECVD]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]] |
||
− | | |
||
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ag |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Al |
+ | |{{Al/E1}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |{{Al/E3}} |
||
− | | <br> |
||
+ | |{{Al/E4}} |
||
− | | <br> |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |{{rl|Sputtering Recipes|Al Deposition (Sputter 4)}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | <br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E2}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Al2O3 Deposition (Sputter 4)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Al2O3_deposition_.28IBD.29 R] |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|Al2O3 deposition (ALD CHAMBER 3)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |AlN |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{rl|Atomic Layer Deposition Recipes|AlN deposition (ALD CHAMBER 3)}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Au |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |B |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |C |
+ | | bgcolor="#eeffff" align="center" |{{rl|E-Beam Evaporation Recipes|Materials Table (E-Beam #1)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" align="center" | |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |CeO<sub>2</sub> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |{{rl|E-Beam Evaporation Recipes|E-Beam 2 (Custom)|CeO<sub>2</sub> deposition (E-Beam 2)}} |
||
− | | <br> |
||
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
+ | | bgcolor="#eeffff" |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Co |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|R]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Cr |
+ | |{{Al/E1}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{Al/E4}} |
||
− | | <br> |
||
+ | |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29 R] |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Cu |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Fe |
+ | |{{Al/E1}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{Al/E4}} |
||
− | | <br> |
||
+ | |[[Sputtering Recipes|R]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ge |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |GeO<sub>2</sub> |
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | | <br> |
||
− | |- |
||
− | ! width="75" bgcolor="#D0E7FF" align="center" | Ir |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | |- |
||
− | ! width="75" bgcolor="#D0E7FF" align="center" | ITO |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
+ | |{{Al/E2}} |
||
| |
| |
||
| |
| |
||
Line 337: | Line 274: | ||
| |
| |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Gd |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Hf |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | bgcolor="EEFFFF" | |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |{{rl|Atomic Layer Deposition Recipes|HfO2 deposition (ALD CHAMBER 3)}} |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |In |
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
− | | |
||
− | | |
+ | |- |
+ | ! bgcolor="#d0e7ff" align="center" |Ir |
||
− | | |
||
+ | |{{Al/E1}} |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ITO |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |{{rl|E-Beam Evaporation Recipes|E-Beam 2 (Custom)|ITO deposition (E-Beam 2)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |MgF2 |
| |
| |
||
| |
| |
||
| |
| |
||
| |
| |
||
+ | |[[Sputtering Recipes|A]] |
||
+ | |[[Sputtering Recipes|A]] |
||
| |
| |
||
| |
| |
||
Line 446: | Line 392: | ||
| |
| |
||
| |
| |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | |- |
||
− | ! width="75" bgcolor="#D0E7FF" align="center" | Si |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |MgO |
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
+ | |{{Al/E2}} |
||
| |
| |
||
| |
| |
||
Line 489: | Line 410: | ||
| |
| |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Mo |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|R]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Nb |
+ | |{{Al/E1}} |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |[[Sputtering Recipes|R]] |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
− | | |
+ | |- |
+ | ! bgcolor="#d0e7ff" align="center" |Nd |
||
| |
| |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |[[Sputtering Recipes|A]] |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ni |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |NiCr |
+ | |{{Al/E1}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
+ | |{{Al/E4}} |
||
| |
| |
||
| |
| |
||
Line 565: | Line 495: | ||
| |
| |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |NiFe |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Pd |
+ | |{{Al/E1}} |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |{{Al/E3}} |
||
− | | |
||
+ | |{{Al/E4}} |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Pt |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}} |
||
− | | bgcolor="EEFFFF" | |
||
+ | | bcolor="EEFFFF" |{{rl|Sputtering Recipes|Sputter 5 (AJA ATC 2200-V)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|Pt deposition (ALD CHAMBER 1)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ru |
+ | |{{Al/E1}} |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |{{Al/E4}} |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |[[Sputtering Recipes#Ru Deposition .28Sputter 4.29|R]] |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |{{rl|Atomic Layer Deposition Recipes|Ru deposition (ALD CHAMBER 1)}} |
||
− | | |
||
+ | |<br> |
||
− | | |
||
− | | |
+ | |- |
+ | ! bgcolor="#d0e7ff" align="center" |Si |
||
− | | |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |{{Al/E2}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|R]] |
||
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/w/index.php?title=PECVD_Recipes#Amorphous-Si_deposition_.28PECVD_.232.29 R] |
||
+ | | bgcolor="#eeffff" | |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiN |
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |{{rl|Sputtering Recipes|SiN deposition (Sputter 3)}} |
||
− | | bgcolor="EEFFFF" | |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |[[Sputtering_Recipes#Si3N4_deposition_.28IBD.29|R]] |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |{{rl|PECVD Recipes|SiN deposition (PECVD #1)}} |
||
− | | bgcolor="EEFFFF" | |
||
+ | |{{rl|PECVD Recipes|SiN deposition (PECVD #2)}} |
||
− | | bgcolor="EEFFFF" | |
||
+ | |{{rl|PECVD Recipes|SiN 250C deposition (Unaxis VLR)}} |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
+ | |<br> |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiN - Low Stress |
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
Line 676: | Line 608: | ||
| |
| |
||
| |
| |
||
+ | |{{rl|PECVD Recipes|Low-Stress SiN - LS-SiN (PECVD#1)}} |
||
+ | |{{rl|PECVD Recipes|Low-Stress SiN deposition (PECVD #2)}} |
||
+ | |{{rl|PECVD Recipes|SiN LS 250C Deposition (Unaxis VLR)}} |
||
| |
| |
||
| |
| |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E2}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|SiO2 deposition (Sputter 3)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
+ | | bgcolor="#eeffff" |[[Sputtering_Recipes#SiO2_deposition_.28IBD.29|R]] |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 deposition (PECVD #1)}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 deposition (PECVD #2)}} |
+ | | bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 LDR 250C Deposition (Unaxis VLR)}} |
||
− | | bgcolor="EEFFFF" | |
||
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|SiO2 deposition (ALD CHAMBER 3)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiO<sub>x</sub>N<sub>y</sub> |
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#SiOxNy_deposition_.28IBD.29 R] |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |[[PECVD_Recipes#PECVD_1_.28PlasmaTherm_790.29|R]] |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Sn |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SrF<sub>2</sub> |
+ | |<br> |
||
− | | |
||
+ | |{{Al/E2}} |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
+ | |<br> |
||
− | | |
||
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ta |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ta deposition (Sputter 3)}} |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor=" |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="EEFFFF" | |
||
− | | bgcolor="EEFFFF" | |
||
|- |
|- |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |{{Al/E2}} |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |[[Sputtering_Recipes#Ta2O5_deposition_.28IBD.29|R]] |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ti |
||
+ | | bgcolor="#eeffff" |{{Al/E1}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |{{Al/E3}} |
||
+ | | bgcolor="#eeffff" |{{Al/E4}} |
||
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
||
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}} |
||
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 5 (AJA ATC 2200-V)}} |
||
+ | | bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |TiN |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |[https://wiki.nanotech.ucsb.edu/w/index.php?title=Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29 R] |
||
+ | |<br> |
||
+ | |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |{{rl|Atomic Layer Deposition Recipes|TiN deposition (ALD CHAMBER 3)}} |
||
+ | |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |TiW |
||
+ | | bgcolor="#eeffff" |{{Al/E1}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
||
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|W-TiW Deposition (Sputter 4)}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |{{Al/E2}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
||
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |[[Sputtering_Recipes#TiO2_deposition_.28IBD.29|R]] |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|TiO2 deposition (ALD CHAMBER 3)}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |V |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |[[Sputtering Recipes|A]] |
||
+ | |[[Sputtering Recipes|A]] |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |W |
||
+ | | bgcolor="#eeffff" |{{Al/E1}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
||
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|W deposition (Sputter 4)}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |Zn |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |ZnO |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZnO:Al deposition (ALD CHAMBER 1)}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |Zr |
||
+ | |{{Al/E1}} |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |{{Al/E4}} |
||
+ | |[[Sputtering Recipes|A]] |
||
+ | |[[Sputtering Recipes|A]] |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |<br> |
||
+ | |- |
||
+ | ! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZrO2 deposition (ALD CHAMBER 3)}} |
||
+ | | bgcolor="#eeffff" |<br> |
||
+ | |- |
||
+ | ! width="20" bgcolor="#d0e7ff" align="center" |'''Material''' |
||
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering Recipes#Sputter_3_.28ATC_2000-F.29|Sputter 3<br>(ATC 2000-F)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(ATC 2200-V)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering Recipes|Sputter 5 (ATC 2200-V)]] |
||
+ | | width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]] |
||
+ | | width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAl)]] |
||
+ | | width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]] |
||
|} |
|} |
||
− | =Recipes= |
||
− | ==E-Beam Evaporation== |
||
− | ===Recipe 1=== |
||
− | #Step 1 .... |
||
− | #Step 2... |
||
− | |||
− | ===Recipe 2=== |
||
− | |||
− | ==Sputtering== |
||
− | |||
− | ==Thermal Evaporation== |
||
− | |||
− | == Plasma Enhanced Chemical Vapor Deposition (PECVD) == |
||
− | |||
− | === SiN deposition === |
||
− | |||
− | #'''Clean''' (30CLN_SN) |
||
− | ##Initial t=10", p=2x10-2, T=250C |
||
− | ##N2 Purge t=30", p=300mT |
||
− | ##evacuate, base pressure=2x10-2, t=10" |
||
− | ##loop |
||
− | ##gas stabilization, t=30" |
||
− | ##etch chamber, t=30' |
||
− | ##evacuate, t=10" |
||
− | ##N2 purge |
||
− | ##evacuate |
||
− | ##loop |
||
− | ##SiN gas stabilization |
||
− | ##SiN deposition( 200A coat) |
||
− | ##evacuate |
||
− | ##N2purge, t=30" |
||
− | ##end |
||
− | #'''SiN deposition''' (SiN_10) 130.8 A/min |
||
− | ##Initial t=10" |
||
− | ##N2 purge t=30" |
||
− | ##evacuate, t=10" |
||
− | ##loop |
||
− | ##SiN gas stabilization, t=30" |
||
− | ##SiN deposition t=8'11.2" |
||
− | ##evacuate, t=10" |
||
− | ##N2 purge t=30" |
||
− | ##evacuate t=10" |
||
− | ##loop |
||
− | |||
− | ==Atomic Layer Deposition (ALD)== |
||
− | |||
− | ==Ion-Beam Deposition (IBD)== |
||
+ | [[Category:Processing]] |
||
− | ==Molecular Vapor Deposition (MVD)== |
Latest revision as of 15:44, 7 July 2022
Process Control Data
See linked page for process control data (calibration data over time, such as dep. rate, refractive index, stress etc.) over time, for a selection of highly used tools/films.
Deposition Tools/Materials Table
- R: Recipe is available. Clicking this link will take you to the recipe.
- A: Material is available for use, but no recipes are provided.