Difference between revisions of "Test Data of etching SiO2 with CHF3/CF4/O2 (using this recipe only for Florine etch of the underneath layer)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(moved SEM link to table, changed "File:" to "Media:")
(Text replacement - "www.nanotech.ucsb.edu/wiki/" to "wiki.nanotech.ucsb.edu/wiki/")
 
(3 intermediate revisions by 2 users not shown)
Line 15: Line 15:
 
|0.63
 
|0.63
 
|
 
|
|[https://www.nanotech.ucsb.edu/wiki/index.php/File:I11902.pdf]
+
|[https://wiki.nanotech.ucsb.edu/wiki/images/3/33/I11902.pdf]
 +
|-
 +
|5/29/2019
 +
|I11904
 +
|71.1
 +
|0.58
 +
|
 +
|[https://wiki.nanotech.ucsb.edu/wiki/images/b/bc/I11904.pdf]
 
|}
 
|}

Latest revision as of 17:31, 6 April 2020

ICP#1: 0.5Pa, 50/500W, CHF3/CF4/O2=35/5/10sccm, time=210 sec
Date Sample# Etch Rate (nm/min) Etch Selectivity (SiO2/PR) Averaged Sidewall Angle (o) SEM Images
1/28/2019 I11902 78.1 0.63 [1]
5/29/2019 I11904 71.1 0.58 [2]