All public logs
Jump to navigation
Jump to search
Combined display of all available logs of UCSB Nanofab Wiki. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
(newest | oldest) View (newer 100 | older 100) (20 | 50 | 100 | 250 | 500)- 16:33, 5 September 2019 Thibeault talk contribs deleted page File:40-Low-stress SiNx at 50 C using Unaxis ICP deposition tool.pdf
- 16:32, 5 September 2019 Thibeault talk contribs deleted page File:41-High-stress SiNx at 50 C using Unaxis ICP deposition tool.pdf
- 16:22, 29 August 2019 Thibeault talk contribs uploaded File:TechTalk20190905.jpg
- 18:16, 29 January 2019 Thibeault talk contribs uploaded File:CA Usage Map 2006-2018.png
- 17:58, 29 January 2019 Thibeault talk contribs uploaded File:US Usage Map 2006-2018.png
- 09:34, 25 January 2019 Thibeault talk contribs uploaded File:2018 User Chart by Discipline.png
- 17:00, 18 January 2019 Thibeault talk contribs uploaded File:User Percentages by Discipline 2018.png
- 16:50, 18 January 2019 Thibeault talk contribs uploaded File:Yearly Users by Affiliation Through 2018.png
- 10:52, 8 November 2018 Thibeault talk contribs uploaded File:DS-K101-304-Anti-Reflective-Coating.pdf
- 09:19, 24 September 2018 Thibeault talk contribs uploaded File:Nanofab Policies Chemical Hygiene Plan 9 13 18.pdf
- 09:36, 8 September 2018 Thibeault talk contribs uploaded File:Nanofab Policies Chemical Hygiene Plan 8 31 18.pdf
- 08:36, 6 September 2018 Thibeault talk contribs uploaded File:BCB-rework.pdf
- 14:35, 19 April 2018 Thibeault talk contribs uploaded File:BCB-adhesion.pdf
- 15:02, 17 January 2018 Thibeault talk contribs uploaded File:10-Si Etch Single Step Smooth Sidewall DSEIII.pdf
- 15:02, 17 January 2018 Thibeault talk contribs uploaded File:10-Si Etch Bosch DSEIII.pdf
- 11:17, 8 September 2017 Thibeault talk contribs uploaded a new version of File:UV26-Positive-Resist-Datasheet.pdf
- 11:16, 8 September 2017 Thibeault talk contribs uploaded File:UV26-Positive-Resist-Datasheet.pdf
- 14:37, 12 June 2017 Thibeault talk contribs uploaded File:NR9-1000PY-AS200-stepperrecipe.pdf
- 14:31, 12 July 2016 Thibeault talk contribs uploaded File:Survey052016.pdf
- 16:52, 3 June 2016 Thibeault talk contribs uploaded File:10-Si Etch Bosch Release DRIE.pdf
- 11:51, 3 June 2016 Thibeault talk contribs uploaded File:ASML Job Set-Up Guide simple v1.pdf
- 17:08, 15 December 2015 Thibeault talk contribs uploaded File:Fe and Co Films using Sputter-3.pdf
- 16:31, 15 December 2015 Thibeault talk contribs uploaded File:DUV42P-Anti-Reflective-Coating.pdf
- 09:12, 27 August 2015 Thibeault talk contribs uploaded File:PEK-162-Positive-Resist-Datasheet.pdf
- 16:01, 26 August 2015 Thibeault talk contribs uploaded File:NR9-6000PY-revA.pdf
- 16:00, 26 August 2015 Thibeault talk contribs uploaded File:NR9-3000PY-revA.pdf
- 16:00, 26 August 2015 Thibeault talk contribs uploaded File:NR9-1000PY-revA.pdf
- 13:54, 9 July 2015 Thibeault talk contribs uploaded File:CAIBE.jpg
- 16:47, 10 April 2015 Thibeault talk contribs uploaded File:ASML Job Set-Up Guide v2.pdf
- 17:26, 2 April 2015 Thibeault talk contribs uploaded File:ASML Mask Making Guidelines.pdf
- 12:41, 23 December 2014 Thibeault talk contribs uploaded File:SiN-AJA-1-Reactive-Sputtering-Power-Flow-AFM-Rate-Index-rev1.pdf
- 12:00, 23 December 2014 Thibeault talk contribs uploaded File:SiO2-AJA-1-Reactive-Sputter-Power-Flow-AFM-Roughness-rev1.pdf
- 11:07, 23 December 2014 Thibeault talk contribs uploaded File:SiO2-AJA-1-Reactive-Sputter-Uniformity-rev-1.pdf
- 11:42, 22 December 2014 Thibeault talk contribs uploaded File:Ti-Au-Sputtering-Films-AJA2-rev1.pdf
- 11:27, 22 December 2014 Thibeault talk contribs uploaded File:Sputter-2-AlN-Endeavor-rev1.pdf
- 16:27, 21 March 2014 Thibeault talk contribs uploaded File:W-TiW-Sputtering-AJA-4-Data-Recipe-RevB.pdf
- 16:08, 21 March 2014 Thibeault talk contribs uploaded File:W-TiW-Sputtering-AJA-4-Data-Recipe-RevA.pdf
- 11:12, 21 March 2014 Thibeault talk contribs uploaded File:Argon-ion-beam-etching-ebeam1-procedure-data-revA.pdf
- 15:36, 18 March 2014 Thibeault talk contribs uploaded File:Al-AFM-Variation-Deposition-Rate-Rev1.pdf
- 15:17, 18 March 2014 Thibeault talk contribs uploaded File:Al-thickness-variation-with-rate.jpg
- 14:54, 18 March 2014 Thibeault talk contribs uploaded File:Vapor-Pressure-Chart-2.xlsx
- 14:52, 18 March 2014 Thibeault talk contribs uploaded a new version of File:Vapor-Pressure-Chart.xlsx
- 14:49, 18 March 2014 Thibeault talk contribs uploaded File:Vapor-Pressure-Chart.xlsx (alphabetical order)
- 14:48, 18 March 2014 Thibeault talk contribs deleted page File:Vapor-Pressure-Chart.xlsx
- 14:47, 18 March 2014 Thibeault talk contribs uploaded a new version of File:Vapor-Pressure-Chart.xlsx
- 14:45, 18 March 2014 Thibeault talk contribs deleted page File:Vapor-Pressure-Chart.xlsx (Deleted old revision 20140318214515!Vapor-Pressure-Chart.xlsx: Duplicated file)
- 14:45, 18 March 2014 Thibeault talk contribs uploaded a new version of File:Vapor-Pressure-Chart.xlsx
- 11:21, 18 March 2014 Thibeault talk contribs uploaded File:Vapor-Pressure-Chart.xlsx
- 11:33, 28 January 2014 Thibeault talk contribs uploaded File:Nanoinprint-Lithopgraphy-UV-Low-Pressure-Temperature-Ormostamp-PDMS-RevA.docx
- 10:58, 28 January 2014 Thibeault talk contribs uploaded File:OrmoPrime-NIL-Adhesion-RevA.pdf
- 10:56, 28 January 2014 Thibeault talk contribs uploaded File:OrmoStamp-NIL-Lithography-UV-Soft-RevA.pdf
- 10:12, 28 January 2014 Thibeault talk contribs uploaded File:Mr-UVCur21.pdf
- 10:59, 27 January 2014 Thibeault talk contribs uploaded File:Lithography-BCB-photo-lowk-dielectric-spinon-4024-40-revA.docx
- 16:38, 24 October 2013 Thibeault talk contribs uploaded File:Panasonic 1-SiC-ICP-RIE-Etch-Plasma-SF6-RevA.pdf
- 15:25, 24 October 2013 Thibeault talk contribs uploaded File:Panasonic1-sapphire-etch-RIE-Plasma-BCl3-ICP-RevA.pdf
- 13:40, 24 October 2013 Thibeault talk contribs uploaded File:Panasonic1-GaAs-PhotonicCrystal-RIE-Plasma-Nanoscale-Etch-RevA.pdf
- 11:34, 24 October 2013 Thibeault talk contribs uploaded File:Panasonic1-GaAs-Via-Etch-Plasma-RIE-Fast-DRIE-RevA.pdf
- 10:14, 24 October 2013 Thibeault talk contribs uploaded File:Panasonic1-GaN-AlGaN-Selective-Etch-Plasma-RIE-ICP-RevA.pdf
- 17:05, 23 October 2013 Thibeault talk contribs uploaded File:RIE2-ITO-Etch-MHA-Plasma-RevA.pdf
- 16:40, 23 October 2013 Thibeault talk contribs uploaded File:RIE2-InGaAs-InP-InAlAs-Etch-Plasma-RIE-RevA.pdf
- 16:11, 23 October 2013 Thibeault talk contribs uploaded File:Panasonic1-TiW-W-Etch-Plasma-RIE-RevA.pdf
- 15:05, 22 October 2013 Thibeault talk contribs uploaded File:Panasonic1-SiN-Etch-Plasma-CF4-O2-ICP-revA.pdf
- 11:40, 22 October 2013 Thibeault talk contribs uploaded File:Panasonic2-ICP-Plasma-Etch-SiN-nanoscale-rev1.pdf
- 11:18, 22 October 2013 Thibeault talk contribs uploaded File:Panasonic2-ICP-Plasma-Etch-SiO2-nanoscale-rev1.pdf
- 15:49, 27 September 2013 Thibeault talk contribs uploaded File:Panasonic-1-Ti-Etch-Deep-RevA.pdf
- 11:53, 27 September 2013 Thibeault talk contribs uploaded File:Panasonic-1-Al-Etch-RevA.pdf
- 11:16, 30 August 2013 Thibeault talk contribs uploaded File:Panasonic1-SiO2-Data-Process-Variation-CHF3-revA.pdf
- 16:06, 18 July 2013 Thibeault talk contribs uploaded File:Holography-Process-Variation-revA.pdf
- 16:05, 18 July 2013 Thibeault talk contribs uploaded File:Holography-Process-Gratings-revA.pdf
- 14:37, 18 July 2013 Thibeault talk contribs uploaded File:Thermal-Nanoimprint-Process-Tutorial-revA.pdf
- 16:58, 10 July 2013 Thibeault talk contribs uploaded File:RemoverPG-revA.pdf
- 16:55, 10 July 2013 Thibeault talk contribs uploaded File:OMNICOAT-revA.pdf
- 16:52, 10 July 2013 Thibeault talk contribs uploaded File:SU-8-2075-revA.pdf
- 16:51, 10 July 2013 Thibeault talk contribs uploaded File:SU-8-2015-revA.pdf
- 16:45, 10 July 2013 Thibeault talk contribs uploaded File:512B-Application-Data-Bake-revA.pdf
- 16:45, 10 July 2013 Thibeault talk contribs uploaded File:512B-Datasheet-revA.pdf
- 16:37, 10 July 2013 Thibeault talk contribs uploaded File:BCB-cyclotene-4000-revA.pdf
- 16:37, 10 July 2013 Thibeault talk contribs uploaded File:BCB-cyclotene-3000-revA.pdf
- 16:10, 10 July 2013 Thibeault talk contribs uploaded File:Panasonic-1-Cr-Etch-revA.pdf
- 16:09, 10 July 2013 Thibeault talk contribs deleted page File:Panasonic-1-Cr-Etch.pdf (will replace)
- 15:29, 10 July 2013 Thibeault talk contribs deleted page File:CrEtch(Panasonic1).pdf (Duplicated file)
- 15:29, 10 July 2013 Thibeault talk contribs uploaded File:Panasonic-1-Cr-Etch.pdf
- 15:27, 10 July 2013 Thibeault talk contribs uploaded a new version of File:CrEtch(Panasonic1).pdf
- 13:48, 18 June 2013 Thibeault talk contribs uploaded File:CrEtch(Panasonic1).pdf
- 14:21, 22 April 2013 Thibeault talk contribs uploaded File:UV210-Positive-Resist-Datasheet.pdf
- 14:20, 22 April 2013 Thibeault talk contribs uploaded File:DS-K101-Anti-Reflective-Coating.pdf
- 14:20, 22 April 2013 Thibeault talk contribs uploaded File:AR2-Anti-Reflective-Coating.pdf
- 14:18, 22 April 2013 Thibeault talk contribs uploaded File:UVN2300-Negative-Resist-Datasheet.pdf
- 14:16, 22 April 2013 Thibeault talk contribs uploaded File:UVN30-Negative-Ressit-Datasheet.pdf (Negative resist for ASML Stepper - UVN2300 requires higher exposure)
- 13:54, 22 April 2013 Thibeault talk contribs uploaded File:UV6-Positive-Resist-Datasheet.pdf (Datasheet for UV6 positive resist for ASML stepper)