User contributions
Jump to navigation
Jump to search
- 10:20, 11 May 2022 diff hist 0 N File:ICP1 07 45D 008.jpg current
- 08:58, 10 May 2022 diff hist 0 m Test Data of etching SiO2 with CHF3/CF4 fixed typo on icp2 cals Tag: Visual edit
- 12:01, 5 May 2022 diff hist +233 m Oxford ICP Etcher - Process Control Data added new entry to oxford 60c cal Tag: Visual edit
- 11:59, 5 May 2022 diff hist 0 N File:InP Oxford 60c 09 CS 005.jpg current
- 11:59, 5 May 2022 diff hist 0 N File:InP Oxford 60c 09 45D 005.jpg current
- 11:53, 5 May 2022 diff hist +264 Test Data of etching SiO2 with CHF3/CF4 Added new entry to ICP2 cals -- after chuck temperature was lowered Tag: Visual edit
- 11:51, 5 May 2022 diff hist 0 N File:ICP2 07 CS 005.jpg current
- 11:50, 5 May 2022 diff hist 0 N File:ICP2 07 45D 002.jpg current
- 09:09, 4 May 2022 diff hist +220 m Test Data of Etching SiO2 with CHF3/CF4-Fluorine ICP Etcher added entry to FL cals Tag: Visual edit
- 09:08, 4 May 2022 diff hist 0 N File:SiO2 Fl 08 CS 005.jpg current
- 09:07, 4 May 2022 diff hist 0 N File:SiO2 Fl 08 45D 004.jpg current
- 14:15, 28 April 2022 diff hist +220 m Unaxis VLR Etch - Process Control Data added new entry to unaxis cals Tag: Visual edit
- 14:13, 28 April 2022 diff hist 0 N File:Unaxis 03 CS 003.jpg current
- 14:12, 28 April 2022 diff hist 0 N File:Unaxis 03 45D 003.jpg current
- 14:09, 28 April 2022 diff hist +202 m Oxford ICP Etcher - Process Control Data added entry to Oxford 60c cals Tag: Visual edit
- 14:04, 28 April 2022 diff hist 0 N File:Oxford 60c 08 CS 009.jpg current
- 14:04, 28 April 2022 diff hist 0 N File:Oxford 60c 08 45D 003.jpg current
- 11:08, 27 April 2022 diff hist +3,202 m Unaxis VLR Etch - Process Control Data merged the two sets of ICP cal data Tag: Visual edit
- 13:32, 26 April 2022 diff hist +299 m Oxford ICP Etcher - Process Control Data added new entry to oxford 60c cal Tag: Visual edit
- 13:31, 26 April 2022 diff hist 0 N File:Oxford 60c 07 CS 001.jpg current