User contributions
Jump to navigation
Jump to search
- 17:00, 19 August 2022 diff hist 0 N File:CS 08052022 pan1 001.jpg current
- 16:59, 19 August 2022 diff hist 0 N File:30D 08052022 pan1 001.jpg current
- 16:58, 19 August 2022 diff hist +253 Test Data of Etching SiO2 with CHF3/CF4-Fluorine ICP Etcher Tag: Visual edit
- 16:52, 19 August 2022 diff hist 0 N File:CS 08192022 FICP 001.jpg current
- 16:51, 19 August 2022 diff hist 0 N File:30D 08192022 FICP 001.jpg current
- 16:47, 19 August 2022 diff hist -13 Oxford ICP Etcher - Process Control Data Tag: Visual edit
- 16:47, 19 August 2022 diff hist +67 N File:InP 07012022 CS 001 copy.jpg Jenky image, but "corrected" date to make it 7/1/2022 current
- 17:25, 12 August 2022 diff hist +76 Oxford ICP Etcher - Process Control Data updated Tag: Visual edit
- 17:18, 12 August 2022 diff hist +32 N File:A734DC5E-639E-4FDC-8F30-6F463470BC27.jpeg InP Etch 8/01/2022 current
- 17:56, 1 August 2022 diff hist +6 Oxford ICP Etcher - Process Control Data Tag: Visual edit
- 17:53, 1 August 2022 diff hist +9 Test Data of etching SiO2 with CHF3/CF4 Tag: Visual edit
- 17:52, 1 August 2022 diff hist 0 N File:CS 002 07-29-22.jpg current
- 17:50, 1 August 2022 diff hist +7 Oxford ICP Etcher - Process Control Data added correct picture Tag: Visual edit
- 17:49, 1 August 2022 diff hist +124 File:45D 001 8-1-22.jpg messed up file name, couldn't figure out how to delete file from wiki so I needed to explain here. current Tag: Visual edit
- 17:46, 1 August 2022 diff hist 0 N File:45D 001 8-1-22.jpg
- 17:44, 1 August 2022 diff hist +195 Oxford ICP Etcher - Process Control Data added data for 8/1 etch cal Tag: Visual edit
- 17:43, 1 August 2022 diff hist 0 File:45D 001.jpg Noahdutra uploaded a new version of File:45D 001.jpg current
- 17:42, 1 August 2022 diff hist 0 File:CS 002.jpg Noahdutra uploaded a new version of File:CS 002.jpg current
- 17:37, 1 August 2022 diff hist +177 Oxford ICP Etcher - Process Control Data added 45d picture for july 1st etch Tag: Visual edit
- 17:33, 1 August 2022 diff hist +42 N File:45D 001.jpg Oxford InP 45D, no NH4OH dip