User contributions
Jump to navigation
Jump to search
- 00:22, 28 November 2017 diff hist +18 Template:News added ' (PST)' to each item for proper date parsing
- 00:14, 28 November 2017 diff hist +1 m User talk:John d current
- 00:14, 28 November 2017 diff hist +179 N User talk:John d leave a msg
- 23:54, 27 November 2017 diff hist +1 m Template:News ]
- 23:53, 27 November 2017 diff hist +73 Template:News link to DSE page, see if RSS link changes accordingly
- 23:50, 27 November 2017 diff hist -65 m Template:News fix four tildes
- 23:48, 27 November 2017 diff hist 0 m Template:News trying level-1 header
- 23:43, 27 November 2017 diff hist +35 m User:John d minor Tag: Visual edit
- 23:37, 27 November 2017 diff hist +721 Template:News updated dates with BT's signature
- 23:23, 27 November 2017 diff hist +790 News Feed copied news items from Template:News
- 23:20, 27 November 2017 diff hist +187 Template:News add instructions
- 23:16, 27 November 2017 diff hist +408 Template:News updated for WikiArticleFeeds RSS format
- 23:11, 27 November 2017 diff hist +328 N News Feed text News page
- 00:46, 18 November 2017 diff hist 0 m Dry Etching Recipes Reverted edits by John d (talk) to last revision by Thibeault
- 00:14, 18 November 2017 diff hist 0 Dry Etching Recipes XeF2: Ge etching possible Tag: Visual edit
- 23:56, 15 November 2017 diff hist +4 m Thermal Processing Recipes minor grammar Tag: Visual edit
- 23:56, 15 November 2017 diff hist +855 Thermal Processing Recipes added some text and links to tools. Tag: Visual edit
- 23:42, 15 November 2017 diff hist +248 m Vacuum Deposition Recipes added IBD "A" recipes for all target metals (Si, Ti, Al, Ta). Tag: Visual edit
- 10:58, 15 November 2017 diff hist +67 m Tool List →Vacuum Deposition: minor speling Tag: Visual edit
- 00:55, 14 November 2017 diff hist -1 m Laser Etch Monitor Simulation in Python minor grammar Tag: Visual edit
- 00:54, 14 November 2017 diff hist 0 File:Laser Etch Monitor v2 - AlGaAs stack.png John d uploaded a new version of File:Laser Etch Monitor v2 - AlGaAs stack.png current
- 00:52, 14 November 2017 diff hist +341 Laser Etch Monitor Simulation in Python aded example laser monitor etch Tag: Visual edit
- 00:48, 14 November 2017 diff hist +70 N File:Laser Etch Monitor v2 - AlGaAs stack.png
- 00:33, 14 November 2017 diff hist +147 m E-Beam Evaporation Recipes →Materials Table (E-Beam #1): explained "positions" and 4 hearths Tag: Visual edit
- 00:31, 14 November 2017 diff hist +196 E-Beam Evaporation Recipes →Materials Table (E-Beam #3): explained which can be dep'd simult., rearranged rows for clarity Tag: Visual edit
- 12:16, 11 November 2017 diff hist -8 Calculators + Utilities →Scripts + Programs: minor formatting Tag: Visual edit
- 12:13, 11 November 2017 diff hist +744 Calculators + Utilities Added "analysis progs" section, with FIJI, Gwyddion links
- 11:12, 11 November 2017 diff hist -11 m Calculators + Utilities scripts + programs section Tag: Visual edit
- 11:11, 11 November 2017 diff hist +39 m Calculators + Utilities added python section
- 11:09, 11 November 2017 diff hist -2 m MediaWiki:Sidebar corrected URL calc/util
- 11:08, 11 November 2017 diff hist +24 m MediaWiki:Sidebar Calculators --> Calculators_+_Utilities
- 11:08, 11 November 2017 diff hist 0 m Calculators + Utilities John d moved page Tools + Calculators to Calculators + Utilities without leaving a redirect: better description
- 11:06, 11 November 2017 diff hist 0 m Calculators + Utilities John d moved page Tools/Calculators to Tools + Calculators without leaving a redirect: slash is confusing for URL path
- 11:05, 11 November 2017 diff hist 0 m Calculators + Utilities John d moved page Calculators to Tools/Calculators without leaving a redirect: more than just calculators
- 10:33, 11 November 2017 diff hist +101 Calculators + Utilities →Python Scripts: added GitHub link for QFIScope Tag: Visual edit
- 19:03, 9 November 2017 diff hist +355 Calculators + Utilities →Python Scripts: added lonk to GitHub repo for Keithley I-V script Tag: Visual edit
- 08:30, 9 November 2017 diff hist +7 m Calculators + Utilities →Refractive Indices: specified Python Tag: Visual edit
- 08:29, 9 November 2017 diff hist -12 m Calculators + Utilities →Python Scripts: updated to same indentation format as other lists Tag: Visual edit
- 08:28, 9 November 2017 diff hist +161 m Calculators + Utilities →Python Scripts: best run in Spyder IDE Tag: Visual edit
- 08:25, 9 November 2017 diff hist +64 m Calculators + Utilities →General Calculators: description for Anaconda/Python Tag: Visual edit
- 08:23, 9 November 2017 diff hist +103 m Calculators + Utilities →Python Scripts: bolded titles Tag: Visual edit
- 08:22, 9 November 2017 diff hist +120 m Calculators + Utilities →Python Scripts: updated description. for Keithely IV-Sweep Tag: Visual edit
- 08:17, 9 November 2017 diff hist +684 Calculators + Utilities →General Calculators: added Python Scripts section Tag: Visual edit
- 08:04, 9 November 2017 diff hist +50 m Calculators + Utilities updated nk.py description Tag: Visual edit
- 08:03, 9 November 2017 diff hist +1,116 N Laser Etch Monitor Simulation in Python link to repository & basic usage info. Tag: Visual edit
- 07:54, 9 November 2017 diff hist +240 Calculators + Utilities added laser etch monitor script, nk.py functions for RIx dispersion models Tag: Visual edit
- 23:31, 6 November 2017 diff hist +379 Calculators + Utilities general calcs Tag: Visual edit
- 23:17, 6 November 2017 diff hist +29 m Calculators + Utilities 1st heading Tag: Visual edit
- 23:16, 6 November 2017 diff hist +404 Calculators + Utilities wet etching section: transene + clawson Tag: Visual edit
- 23:11, 6 November 2017 diff hist +18 m Calculators + Utilities headings Tag: Visual edit
- 23:10, 6 November 2017 diff hist +72 m Calculators + Utilities newlines between sections Tag: Visual edit
- 23:07, 6 November 2017 diff hist +855 N Calculators + Utilities initial - links ot external pages/calculators Tag: Visual edit
- 22:45, 6 November 2017 diff hist 0 m MediaWiki:Sidebar calc testing
- 22:44, 6 November 2017 diff hist -1 m MediaWiki:Sidebar calc tests
- 22:43, 6 November 2017 diff hist +11 m MediaWiki:Sidebar fixed calc link
- 22:43, 6 November 2017 diff hist 0 m MediaWiki:Sidebar moved calculators into recipes/data
- 22:41, 6 November 2017 diff hist +24 MediaWiki:Sidebar Added Calculators section
- 22:37, 6 November 2017 diff hist -24 m Sputtering Recipes unbolded titles Tag: Visual edit
- 08:11, 2 November 2017 diff hist +191 Sputtering Recipes →Sputter 5 (Lesker AXXIS): Noted that this tool has been replaced by an AJA sputter Tag: Visual edit
- 14:41, 31 October 2017 diff hist 0 Vacuum Deposition Recipes fixed C bgcolor color
- 14:39, 31 October 2017 diff hist +6 m Sputter 3 (AJA ATC 2000-F) →Detailed Specifications: reworded Tag: Visual edit
- 14:37, 31 October 2017 diff hist +8 m Sputter 4 (AJA ATC 2200-V) →Detailed Specifications: reworded Tag: Visual edit
- 14:36, 31 October 2017 diff hist +6 m Sputter 4 (AJA ATC 2200-V) bolded signupmonkey link Tag: Visual edit
- 14:36, 31 October 2017 diff hist +153 Sputter 4 (AJA ATC 2200-V) added singupmonkey link for currently installed targets Tag: Visual edit
- 14:34, 31 October 2017 diff hist +161 Sputter 3 (AJA ATC 2000-F) Added link to signupmnkey page for currently installed targets Tag: Visual edit
- 17:31, 12 October 2017 diff hist +1 m Thermal Evaporator 1 added missing { current
- 21:23, 8 October 2017 diff hist +13 m PECVD Recipes →OTHER recipes: LS SiN and SiOxNy deposition (PECVD #1): added "low stress' text Tag: Visual edit
- 22:06, 7 October 2017 diff hist +46 m PECVD Recipes →LS SiN deposition (PECVD #2): added text “low stress” for clarity and google searches Tag: Visual edit
- 00:55, 7 October 2017 diff hist +10 m ICP Etching Recipes →SiO2 Etching (Panasonic 2): referred "SiOVert" Tag: Visual edit
- 00:54, 7 October 2017 diff hist +40 m ICP Etching Recipes →SiO2 Etching (Panasonic 1): referred to "SiOVert", the colloquial name for this "std." provided recipe. Tag: Visual edit: Switched
- 00:50, 7 October 2017 diff hist +1 m ICP Etching Recipes →Bosch and Release Etch (Si Deep RIE): >>1µm Tag: Visual edit
- 00:49, 7 October 2017 diff hist +15 m Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) minor
- 00:46, 7 October 2017 diff hist +28 Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP) →Recipes: link to ICP Etching / recipes section Tag: Visual edit: Switched
- 00:39, 7 October 2017 diff hist +357 ICP Etching Recipes →Bosch and Release Etch (Si Deep RIE): added basic info about bosch process, including new IBD Al2O3 etch selectivity info. Tag: Visual edit
- 22:26, 3 October 2017 diff hist -2 m Template:Nav processes --> recipes
- 14:18, 22 September 2017 diff hist +3 m Dry Etching Recipes Added "A" for GaSb, InP Tag: Visual edit
- 14:16, 22 September 2017 diff hist 0 m Dry Etching Recipes moves Si into proper alphabetical row Tag: Visual edit
- 14:14, 22 September 2017 diff hist +71 Dry Etching Recipes Added Ta2O5 etching, described in paper by Blumenthal Group. Tag: Visual edit
- 14:05, 22 September 2017 diff hist +26 m Dry Etching Recipes removed spurious column |- text, alphabetizing.
- 13:59, 22 September 2017 diff hist 0 m Dry Etching Recipes alphabetized mostly Tag: Visual edit
- 13:52, 22 September 2017 diff hist -2 m Dry Etching Recipes partially alphabetized and removed one spurious row Tag: Visual edit: Switched
- 13:44, 22 September 2017 diff hist -12 m E-Beam Evaporation Recipes →ITO deposition (E-Beam 2): removed bold titles Tag: Visual edit
- 13:44, 22 September 2017 diff hist +22 m E-Beam Evaporation Recipes →Materials Table (E-Beam #1): updated Carbon rates Tag: Visual edit
- 13:42, 22 September 2017 diff hist +57 m E-Beam 1 (Sharon) included "electron beam" & "deposition parameters" to boost in google search Tag: Visual edit
- 16:45, 19 September 2017 diff hist +116 ICP Etching Recipes →SiO2 Etching (Panasonic 2): linked to ICP#1 params Tag: Visual edit: Switched
- 16:42, 19 September 2017 diff hist +127 m ICP Etching Recipes →SiO2 Etching (Panasonic 1): added etch rate, unknown selectivity Tag: Visual edit
- 15:25, 19 September 2017 diff hist +6 E-Beam Evaporation Recipes →Materials Table (E-Beam #1): (minor) Carbon, bolded formatting Tag: Visual edit
- 15:24, 19 September 2017 diff hist +8 m E-Beam Evaporation Recipes added "carbon" for search engines Tag: Visual edit
- 08:48, 19 September 2017 diff hist 0 Vacuum Deposition Recipes fix row color?
- 08:46, 19 September 2017 diff hist +657 Vacuum Deposition Recipes fixed table row color
- 08:42, 19 September 2017 diff hist +517 Vacuum Deposition Recipes Added Carbon on EBeam #1 Tag: Visual edit: Switched
- 19:58, 8 September 2017 diff hist +14 m High Temp Oven (Blue M) removed "8 steps" Tag: Visual edit: Switched
- 19:57, 8 September 2017 diff hist +276 High Temp Oven (Blue M) added description of processes etc. Tag: Visual edit: Switched
- 19:54, 8 September 2017 diff hist +130 Tool List →Thermal Processing: added ovens from "lithography" section
- 17:13, 7 September 2017 diff hist 0 m Spin Rinse Dryer (SemiTool) tool template @ top
- 17:13, 7 September 2017 diff hist +295 Spin Rinse Dryer (SemiTool) added description + capabilities, Tag: Visual edit: Switched
- 10:14, 5 September 2017 diff hist +2 Lithography Recipes →E-Beam Lithography Recipes: testing visual editor Tag: Visual edit: Switched
- 09:37, 5 September 2017 diff hist +159 E-Beam Evaporation Recipes added Carbon, bolded "use with permission only" on oxides. Tag: Visual edit: Switched
- 13:05, 1 September 2017 diff hist +32 Lithography Recipes →General Information: linked to PR/EBL datasheet sec
- 13:03, 1 September 2017 diff hist +11 m Lithography Recipes →General Information: nanoimprinting recipes section title correctly