User contributions
Jump to navigation
Jump to search
- 13:52, 22 September 2017 diff hist -2 m Dry Etching Recipes partially alphabetized and removed one spurious row Tag: Visual edit: Switched
- 13:44, 22 September 2017 diff hist -12 m E-Beam Evaporation Recipes →ITO deposition (E-Beam 2): removed bold titles Tag: Visual edit
- 13:44, 22 September 2017 diff hist +22 m E-Beam Evaporation Recipes →Materials Table (E-Beam #1): updated Carbon rates Tag: Visual edit
- 13:42, 22 September 2017 diff hist +57 m E-Beam 1 (Sharon) included "electron beam" & "deposition parameters" to boost in google search Tag: Visual edit
- 16:45, 19 September 2017 diff hist +116 ICP Etching Recipes →SiO2 Etching (Panasonic 2): linked to ICP#1 params Tag: Visual edit: Switched
- 16:42, 19 September 2017 diff hist +127 m ICP Etching Recipes →SiO2 Etching (Panasonic 1): added etch rate, unknown selectivity Tag: Visual edit
- 15:25, 19 September 2017 diff hist +6 E-Beam Evaporation Recipes →Materials Table (E-Beam #1): (minor) Carbon, bolded formatting Tag: Visual edit
- 15:24, 19 September 2017 diff hist +8 m E-Beam Evaporation Recipes added "carbon" for search engines Tag: Visual edit
- 08:48, 19 September 2017 diff hist 0 Vacuum Deposition Recipes fix row color?
- 08:46, 19 September 2017 diff hist +657 Vacuum Deposition Recipes fixed table row color
- 08:42, 19 September 2017 diff hist +517 Vacuum Deposition Recipes Added Carbon on EBeam #1 Tag: Visual edit: Switched
- 19:58, 8 September 2017 diff hist +14 m High Temp Oven (Blue M) removed "8 steps" Tag: Visual edit: Switched
- 19:57, 8 September 2017 diff hist +276 High Temp Oven (Blue M) added description of processes etc. Tag: Visual edit: Switched
- 19:54, 8 September 2017 diff hist +130 Tool List →Thermal Processing: added ovens from "lithography" section
- 17:13, 7 September 2017 diff hist 0 m Spin Rinse Dryer (SemiTool) tool template @ top
- 17:13, 7 September 2017 diff hist +295 Spin Rinse Dryer (SemiTool) added description + capabilities, Tag: Visual edit: Switched
- 10:14, 5 September 2017 diff hist +2 Lithography Recipes →E-Beam Lithography Recipes: testing visual editor Tag: Visual edit: Switched
- 09:37, 5 September 2017 diff hist +159 E-Beam Evaporation Recipes added Carbon, bolded "use with permission only" on oxides. Tag: Visual edit: Switched
- 13:05, 1 September 2017 diff hist +32 Lithography Recipes →General Information: linked to PR/EBL datasheet sec
- 13:03, 1 September 2017 diff hist +11 m Lithography Recipes →General Information: nanoimprinting recipes section title correctly