Difference between revisions of "Logitech WBS7 - Procedure for Wax Mounting with bulk Crystalbond Stick"
Jump to navigation
Jump to search
(added POLOS cleaning step) |
(comment about wax on filter paper) |
||
Line 14: | Line 14: | ||
**Align work wafer on top of handle wafer placed. |
**Align work wafer on top of handle wafer placed. |
||
**Align the two wafers' flats. |
**Align the two wafers' flats. |
||
− | *Place 6" |
+ | *Place 6" filter paper on <u>top and bottom</u> of work wafer. |
*Turn on Logitech bonder power (bottom right of machine chassis) |
*Turn on Logitech bonder power (bottom right of machine chassis) |
||
*Close and lock Logitech bonder hatch. |
*Close and lock Logitech bonder hatch. |
||
Line 38: | Line 38: | ||
*Process takes about 45min |
*Process takes about 45min |
||
**Unload when it displays ''Status: Ready'' |
**Unload when it displays ''Status: Ready'' |
||
+ | **It is normal to see wax on the filter paper, indicating full/over-coverage. However you might need to adjust the wax amount to prevent too much wax escaping the wafer and causing too thick a bonding layer. About ~1cm of leaking wax on the filter paper is ideal. |
||
− | *If wax leaked onto the glass plate: remove glass plate and clean with Acetone+Wipe. |
+ | *If wax leaked onto the glass plate: remove glass plate and clean with Acetone+Wipe. The sufaces must be very clean of wax when you're done, or else the lid or wafers may get stuck on the next run. |
*Turn off Logitech bonder (bottom right of machine chassis) |
*Turn off Logitech bonder (bottom right of machine chassis) |
||
**Close lid and clamp |
**Close lid and clamp |
||
− | *Clean excess wax off your wafer using the [[Wet Benches#Automated Wet-processing Spinners .28POLOS.29|POLOS Spinners]], and an Acetone squirt bottle, followed by ISO & N2 dry (run both sides of the wafer). |
+ | *Clean excess wax off your wafer using the [[Wet Benches#Automated Wet-processing Spinners .28POLOS.29|POLOS Spinners]], and an Acetone squirt bottle, followed by ISO & N2 dry (run both sides of the wafer, multiple times if needed). |
Revision as of 10:36, 26 April 2023
Contributed by Miguel Daal, Mazin Group -- 2018-04-24
Procedure for wax-mounting a 100mm Silicon wafer to another 100mm silicon carrier wafer, using the Logitech WBS7 Wafer Bonder.
- Cover Hotplate surface with tinfoil, heat hotplate to 120°C. (Keep flammable solvents away!)
- Place 4" polished handle wafer on hotplate.
- Apply wax to center of wafer only, approximately 2-inch diameter size puddle of crystal bond wax directly from the crystalbond stick.
- For mounting a 4-inch wafer, you need a good amount of wax to ensure coverage to wafer edges, eg.2-3mm thick.
- Then remove wafer from hotplate. and cool.
- Open Logitech Bonder chamber:
- Unscrew clamp until higher than clamp arm,
- Swing front of clamp arm to the left (Difficult to disengage),
- Lift bonder lid (also takes some force to open - ignore vacuum reading on digital display)
- On the glass plate of the Logitech bonder:
- Align work wafer on top of handle wafer placed.
- Align the two wafers' flats.
- Place 6" filter paper on top and bottom of work wafer.
- Turn on Logitech bonder power (bottom right of machine chassis)
- Close and lock Logitech bonder hatch.
- On front panel of Logitech bonder, confirm that Applied Pressure gauge is set to 5 psi.
- Enter the process settings:
- [setup] -> [Temp]
- Bonding: 120°C
- Endpoint: 65°C
- Offset: 20°C
- Units: C
- [setup] -> [Vac Thres]
- Proceed if Below: 2.4E+01 mBar
- Abort if Below: 3.2E+01 mBar
- [setup] -> [Process Control]
- Process: Heat + Outgas
- Soak: 5min
- Bond: 15min
- O.G. Limit: 20min
- P.P. del: 1min
- [Setup] -> [Heads]
- Head 1 On
- [setup] -> [Temp]
- Start Process: [Process] -> [Start]
- Process takes about 45min
- Unload when it displays Status: Ready
- It is normal to see wax on the filter paper, indicating full/over-coverage. However you might need to adjust the wax amount to prevent too much wax escaping the wafer and causing too thick a bonding layer. About ~1cm of leaking wax on the filter paper is ideal.
- If wax leaked onto the glass plate: remove glass plate and clean with Acetone+Wipe. The sufaces must be very clean of wax when you're done, or else the lid or wafers may get stuck on the next run.
- Turn off Logitech bonder (bottom right of machine chassis)
- Close lid and clamp
- Clean excess wax off your wafer using the POLOS Spinners, and an Acetone squirt bottle, followed by ISO & N2 dry (run both sides of the wafer, multiple times if needed).