Difference between revisions of "Lithography Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
Line 86: Line 86:
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}  
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}  
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}  
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}  
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
Line 96: Line 96:
 
| {{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}  
 
| {{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}  
 
| {{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}  
 
| {{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}  
| <br>
+
| A
| <br>
+
| A
 
| <br>  
 
| <br>  
 
| <br>  
 
| <br>  
Line 106: Line 106:
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}  
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MJB-3)}}  
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}  
 
| bgcolor="EEFFFF" | {{rl|Contact_Alignment_Recipes|Positive Resist (MA-6)}}  
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
Line 114: Line 114:
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" | OCG 825-35CS  
 
| bgcolor="#D0E7FF" align="center" | OCG 825-35CS  
| <br>
+
| A
| <br>
+
| A
| <br>
+
| A
| <br>
+
| A
 
| <br>  
 
| <br>  
 
| <br>  
 
| <br>  
Line 124: Line 124:
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" | SPR 950-0.8  
 
| bgcolor="#D0E7FF" align="center" | SPR 950-0.8  
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
Line 134: Line 134:
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" | SPR 955 CM-0.9  
 
| bgcolor="#D0E7FF" align="center" | SPR 955 CM-0.9  
| <br>
+
| A
| <br>
+
| A
 
| {{rl|Stepper Recipes|Positive Resist (GCA 6300)}}  
 
| {{rl|Stepper Recipes|Positive Resist (GCA 6300)}}  
 
| {{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}  
 
| {{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}  
Line 144: Line 144:
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" | SPR 955 CM-1.8  
 
| bgcolor="#D0E7FF" align="center" | SPR 955 CM-1.8  
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
 
| bgcolor="EEFFFF" | {{rl|Stepper Recipes|Positive Resist (GCA 6300)}}  
 
| bgcolor="EEFFFF" | {{rl|Stepper Recipes|Positive Resist (GCA 6300)}}  
 
| bgcolor="EEFFFF" | {{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}  
 
| bgcolor="EEFFFF" | {{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}  
Line 176: Line 176:
 
| <br>  
 
| <br>  
 
| <br>  
 
| <br>  
| <br>
+
| A
| <br>
+
| A
 
| <br>  
 
| <br>  
 
| <br>  
 
| <br>  
Line 188: Line 188:
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
| bgcolor="EEFFFF" |  
+
| bgcolor="EEFFFF" | A
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
 
| bgcolor="EEFFFF" |  
Line 218: Line 218:
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" | AZnLOF 2035  
 
| bgcolor="#D0E7FF" align="center" | AZnLOF 2035  
|  
+
| A
|  
+
| A
|  
+
| A
|  
+
| A
 
|  
 
|  
 
|  
 
|  
Line 228: Line 228:
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" | AZnLOF 2070  
 
| bgcolor="#D0E7FF" align="center" | AZnLOF 2070  
|  
+
| A
|  
+
| A
|  
+
| A
|  
+
| A
 
|  
 
|  
 
|  
 
|  
Line 237: Line 237:
 
|  
 
|  
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
| bgcolor="#D0E7FF" align="center" | AZnLOF P5510
+
| bgcolor="#D0E7FF" align="center" | AZnLOF 5510
|  
+
| A
|  
+
| A
 
| {{rl|Stepper Recipes|Negative Resist (GCA 6300)}}  
 
| {{rl|Stepper Recipes|Negative Resist (GCA 6300)}}  
 
| {{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}  
 
| {{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}  
Line 252: Line 252:
 
|  
 
|  
 
|  
 
|  
|  
+
| A
 
|  
 
|  
 
|  
 
|  
Line 258: Line 258:
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" | SU-8 2015  
 
| bgcolor="#D0E7FF" align="center" | SU-8 2015  
|  
+
| A
|  
+
| A
|  
+
| A
|  
+
| A
 
|  
 
|  
 
|  
 
|  

Revision as of 13:52, 22 April 2013

Lift-Off Techniques

Chemical Datasheets

Positive Photoresists
Negative Photoresists
Underlayers
E-beam resists
Nanoimprinting
Contrast Enhancement Materials
Anti-Reflection Coatings
Developers
Photoresist Removers

Recipes

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.


Lithography Recipes

Contact Aligners Steppers Flood Expose E-Beam Lithography
Positive Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


AZ4110 R R A A
AZ4210 R R A A



AZ4330RS R R A A
OCG 825-35CS A A A A



SPR 950-0.8 A A A A
SPR 955 CM-0.9 A A R R



SPR 955 CM-1.8 A A R R
SPR 220-3.0 R R R R



SPR 220-7.0 R R R R
THMR-IP3600 HP D

A A



UV6-0.7 A
Negative Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


AZ5214-EIR R R R R
AZnLOF 2020 R R R R
AZnLOF 2035 A A A A
AZnLOF 2070 A A A A
AZnLOF 5510 A A R R
UVN30-0.5 A
SU-8 2015 A A A A
Underlayers SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


PMGI SF-11







PMGI SF-15
LOL 2000
XHRIC-11 (BARC)
AR-2 (BARC)
DS-K 101-307 (BARC)
Overlayers SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


CEM-365 IS
E-Beam Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


 ??????
 ???????
Nanoimprint Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


MR-I 7020
Nanonex NX-1020
SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)